Data integration from heterogeneous data sources in low-voltage (LV) power distribution grids will be valuable to distribution system operators (DSOs). The power measurements from customer premises need to be processed with other data such as grid topology, line parameters etc., to deploy smart grid applications (SGA) such as real-time grid monitoring and voltage regulation. The most challenging task for DSOs is to collect and integrate data from several sources as several entities are involved in the data management and access to databases are restricted. This paper presents an op E n common information ${M}$ odel (CIM) BA sed sma ${R}$ t grid application framewor ${K}$ ( EMBARK ) to address the above-mentioned challenge. EMBARK is developed to be an efficient, modular and scalable architecture for extracting relevant grid related information from various asset management databases. A novel data management functionality is a part of EMBARK that enables data-driven update of settings and parameters of the algorithms behind smart grid applications. The proposed approach is demonstrated and numerically validated using grid data from a medium-sized distribution grid operator in Denmark. The architecture developed and presented in this paper can support all the phases from planning to the actual smart grid operation, i.e., automatically building the models to perform load flows, grid impact studies, planning, asset management etc.
16 February 2023 in International Journal of Electrical Power & Energy Systems
This research aims to design a modified P&O algorithm for the efficient tracking of maximum power point (MPPT) for standalone and grid-connected systems. The proposed research work modifies the P&O algorithm for the dc-dc converter where the fixed step size P&O algorithm is translated into variable step size with the help of ant colony optimization (ACO) to generate optimal parameters for the PID controller to generate a variable step size in the P&O algorithm. This variable step size is dependent upon the error that is the difference between the generated power and desired power. By doing this it improves the efficiency of the P&O algorithm and its limitations are overcome. Furthermore, the PV is extended to connect with a grid where the inverter is controlled by a fuzzy logic controller (FLC) so that the combined structure of variable P&O and fuzzy helps to achieve MPP efficiently. The robustness of the proposed work is compared with other state-of-the-art controllers to justify the effectiveness of the proposed work. Finally, a stability test of the system is carried out to verify the overall stability of the power system.
The purpose of this study is to evaluate and compare how well different routing protocols perform in terms of load sharing, link failover, and overall network performance. Wireshark was used for packet-level analysis, VMWare was used for virtualization, GNS3 was used for network simulation, and Iperf3 was used to measure network performance parameters. Convergence time, packet losses, network jitter, and network delay are the parameters that were selected for assessment. To examine the behaviors of Open Shortest Path First (OSPF) and Enhanced Interior Gateway Routing Protocol (EIGRP) routing protocols in a variety of network settings, a simulated network environment incorporating both protocols along with Border Gateway Protocol (BGP) is created for the research. The setup for the experiment entails simulating different network conditions, such as fluctuating traffic loads and connection failures, to track how the protocols function in dynamic situations. The efficiency metrics for OSPF and EIGRP with BGP are measured and evaluated using the data generated by Wireshark and Iperf3. The results of this research show that EIGRP has a better failover convergence time and packet loss percentage as compared to the OSPF.
The demand for energy is increasing at an abrupt pace, which has highly strained the power system, especially with high share of power generation from renewable energy sources (RES). This increasing strain needs to be effectively managed for a continuous and smooth operation of the power system network. Generation and demand exhibit a strong correlation that directly creates an impact on the power system frequency. Fluctuations and disruptions in load frequency can manifest themselves as over-voltages and physical damages in the power grid and, in the worst case, can lead to blackouts. Thus, this paper proposed an effective solution to mitigate the load frequency problem(s), which is initiated by the changing load demand under high penetration of RES. This paper presented an improved cascaded structure, the proportional integral with a fractional operator coupled with proportional derivative . The proposed modifies the (1+PD) controller by introducing fractional properties that improve its tracking efficiency and mitigate frequency fluctuations taking minimal time. The introduction of diversifies its tracking and overall controlling ability, which translates it as a significant controller. The controller optimal parameters are extracted by deploying a dragonfly search algorithm (DSA). The study of the results illustrates that the proposed design displays efficient performance under any disturbance or uncertainty in the power system.
15 June 2024 in International Journal of Critical Infrastructure Protection