The increasingly frequent use of computer simulations for in calculations concerning water supply systems requires accounting for demand patterns. Determining coefficients of daily and hourly non-uniformity is indispensable for correct designing or modernization of pipes in the water supply...
1 January 2021 in Journal of Ecological Engineering
The topic of failures and water losses in the urban-rural water supply network was discussed. The purpose of the work was to assess the level of real water losses and the failure rate of the urban-rural water supply network in 2010-2016. The article's introduction contains information on the...
Delivering water to consumers uses a lot of electricity. In the era of limited fossil fuel resources, we are increasingly looking at the possibilities of using renewable energy sources to power residential buildings or industries. The research aimed to analyze the potential of producing electricity from photovoltaic panels, ensuring electricity supplies for pumping water, and reducing costs. The tests were carried out using the existing photovoltaic (PV) installation with a capacity of 12.3 kW connected to the installation monitoring the production of electricity and monitoring the water-pumping station (WPS). An analysis of the daily electricity production from the PV installation, an analysis of the settlement unit’s demand for water, and an analysis of the costs of pumping water, including the unit cost of pumping 1 m3 of water, were carried out. Studies have shown the possibility of reducing water-pumping costs by more than 77.8% after a PV installation. The tested installation provided 100% of the electricity necessary for WPS for 167 days a year.
Taking care of water resources and minimizing water losses in water supply networks requires a broad approach to identifying and neutralizing operational problems. The correct selection of water meters to minimize apparent losses requires knowledge of the characteristic flows that may occur in the facility to which water is supplied. The research aimed to develop tools in the form of mathematical models and water consumption curves along with hourly water consumption coefficients to facilitate the process of selecting water meters for engineers and creating computer models of water supply systems. The research involved monitoring the flow of 76 single-family and multi-family buildings in four towns in Poland, followed by data analysis and development of tools supporting the selection of water meters and the construction of computer models of water distribution networks. High correlation coefficients of the studied variables indicate the results’ usefulness. Four models were developed to determine the maximum flow values in multi-family buildings (three models) and single-family buildings (one model) in the range of water meter diameters DN15-DN40. Characteristics of the average hourly peak coefficient (HPC) values were also developed, along with the range of changes in HPC values for single-family and multi-family buildings.
The increase in electricity generation prices represents a reason why water utility companies are looking for ways to reduce costs. One of the first ideas of users was to build photovoltaic installations. Water treatment plants or sewage treatment plants usually have large unused areas. They look different in facilities that consume a lot of energy but occupy little land, and include water intakes (wells) and water pumping stations. Facilities equipped with pumps are characterized by high electricity consumption. This article assesses the possibility of using PV installations at the water intake. An analysis of energy production from the 3.0 kW PV installation in Polanica-Zdrój was carried out, and then, simulations of the possibility of providing energy via installations with capacities of 3.0 kW, 4.2 kW, and 6.0 kW were performed. Analyses of energy production and demand, as well as analyses of water production based on annual, monthly, daily, and hourly data, were performed. An analysis of the hourly coverage of the WPS’s demand for electricity was carried out with regard to the current production of energy from the PV installation, as was an analysis of the overproduction of energy from the PV installation regarding the energy demand of the WPS. The simulation results are presented for cloudy and sunny days.
University dormitories constitute a unique category of residential buildings characterized by highly variable occupancy patterns, intensive daily water use and strong seasonal fluctuations associated with the academic calendar. Despite their importance, detailed long-term investigations based on high-resolution smart metering data remain scarce. This study presents a comprehensive analysis of one-year high-resolution (15 min interval) water consumption measurements collected from four university dormitories (Bialystok Technical University). The objectives were to characterize temporal water demand patterns, identify similarities and differences between buildings, determine hourly, daily and seasonal variability, and calculate peak demand coefficients relevant to water supply system design and operation. The results revealed a characteristic daily demand pattern consisting of low night-time demand, a gradual morning increase and a dominant evening peak. Seasonal variability and differences between individual dormitories were observed, although the overall shape of the hourly demand profiles remained highly repeatable throughout the monitoring period. Based on the obtained results, representative hourly demand profiles and hourly demand pattern coefficients were developed for individual dormitories, the entire dormitory campus, weekdays and weekends. The proposed profiles provide building-type-specific reference demand patterns that may support hydraulic modeling and further smart metering applications.