Many researchers have taken advantage of adding shape memory alloy (SMA) wires to base isolators to control displacements and residual deformations. In the literature, different arrangements of SMA wires wrapped around the rubber bearings can be found, as examples, straight, cross and double-cross arrangements. SMA wires with various configurations and radii lead to the different characteristics of the isolator system and thus various shear hysteresis. Therefore, the aim of this study is to evaluate the performance of these three SMA wire’s configurations in the seismic retrofitting of a benchmark highway bridge by implementing them in the bridge’s existing lead rubber bearings (LRB). This system is referred to as SMA-LRB isolator. Firstly, because of the crucial influence of the wire’s radius, this parameter is determined using a multi-objective optimization algorithm (non-dominated sorting genetic algorithm (NSGA)-II). This algorithm simultaneously minimizes the deck acceleration and mid-span displacement. Secondly, the optimized SMA-LRBs are implemented in the highway bridge and nonlinear dynamic analysis is conducted. For the nonlinear response history analysis, two strong ground motion records are selected from the PEER database, by studying the site’s conditions. In addition, ten synthetic ground acceleration time histories are generated. The result illustrates that the double-cross SMA-LRB reduces the maximum and residual displacements more than two other devices; however, it causes the largest base shear force and deck acceleration. Besides, the cross-configuration results in the least displacement reduction and has the least shear force and acceleration. To find SMA-LRB with the best overall performance, a multi-objective decision-making method is utilized and the straight SMA-LRB is recognized as the most effective isolator.
External retrofit of beam-column joints in old fashioned RC structures seismic retrofit;old fashioned RC structures;exterior and interior beam-column joints;plain bars, steel angles prestressed by cross ties; There has been increasing attention in many countries on seismic retrofit of old fashioned RC structures in recent years. In such buildings, the joints lack transverse reinforcement and suffer inadequate seismic dimensional requirements and the reinforcement is plain bar. The behavior of the joints is governed by sliding of steel bars and diagonal shear failure is less influential. Different methods to retrofit beam-column joints have been proposed in the literature such as wrapping the joint by FRP sheets, enlargement of the beam-column joint, and strengthening the joint by steel sheets. In this study, an enlargement technique that uses external prestressed cross ties with steel angles is examined. The technique has already been used for substructures reinforced by deformed bars and has advantages such as efficient enhancement of seismic capacity and lack of damage to the joint. Three reference specimens and two retrofitted units are tested under increasing lateral cyclic load in combination with two levels of axial load. The reference specimens showed relatively low shear strength of 0.150${\surd}$($f_c$) and 0.30${\surd}$($f_c$) for the exterior and interior joints, respectively. In addition, relatively brittle behavior was observed and large deformations extended into the panel zone of the joints. The retrofit method has increased ductility ratio of the interior beam-column joints by 63%, and energy dissipation capacity by 77%, relative to the control specimen; For external joints, these values were 11%, and 94%. The retrofit method has successfully relocated the plastic joints far from the column face. The retrofit method has improved shear strength of the joints by less than 10%.
In this paper, an evolutionary multi-objective optimization algorithm named NSGA-II was used to determine the optimum radius for shape memory alloy (SMA) wires employed in conjunction with the lead rubber bearing (LRB), referred to as an SMA-LRB isolator. This algorithm simultaneously minimizes the mid-span displacement and the base shear force. Then, the optimized SMA-LRBs were implemented in a benchmark bridge to reduce excessive displacements. The results obtained from the nonlinear dynamic analysis show that the implemented approach could effectively optimize the SMA-LRBs. These improved smart isolators can noticeably reduce the maximum displacements and residual deformations of the structure; meanwhile, the base shear and deck acceleration remain less than those of the non-isolated benchmark bridge. This isolator can reduce the maximum mid-span displacement of the bridge by up to 61%, and the mid-span residual deformations by up to 100%, compared to an uncontrolled isolated bridge under different ground motions. This optimized passive system was compared with nonlinear dampers, passive SMA dampers, and a negative stiffness device. The results indicate that the optimized SMA-LRB isolators are generally more successful in reducing and recovering displacements than the other controllers.