Katrin Sturm

Dr. Katrin Sturm

Seqwater, Ipswich, Queensland, Australia

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2014 in Environmental Science & Technology
Verified
Journal Article
Closed access
RMRonald S. Musenze
Ronald S. Musenze
AGAlistair Grinham
Alistair Grinham
UWUrsula Werner
Ursula Werner
DGDeborah Gale
Deborah Gale
KSKatrin Sturm
Katrin Sturm
ZYZhiguo Yuan
Zhiguo Yuan

18 May 2015 in Limnology and Oceanography: Methods
Verified
Journal Article
Open access
PDF file
KSKatrin Sturm
Katrin Sturm
BKBeatrice Keller‐Lehmann
Beatrice Keller‐Lehmann
UWUrsula Werner
Ursula Werner
Keshab SharmaKeshab Sharma
Keshab Sharma
AGAlistair Grinham
Alistair Grinham
ZYZhiguo Yuan
Zhiguo Yuan
Pre‐evacuated Exetainers are commonly used as measurement vials for the determination of methane (CH4) and nitrous oxide (N2O) concentrations in liquid and gaseous samples from aquatic environments. The impact of residual air in these Exetainers on measurement accuracy is assessed. Residual air pressure in commercially available, pre‐evacuated Exetainers varied between 0.071 ± 0.008 atm and 0.180 ± 0.031 atm in examined batches. This background contamination can lead to large errors when determining dissolved and gaseous CH4 and N2O concentrations particularly at low concentrations. A method for Exetainer pretreatment is suggested and verified, to reduce the residual CH4 and N2O. Vials are flushed (needle 30 G × 0.5″, 0.3 mm) with nitrogen gas (N2) for 5 min, which reduces the background CH4 and N2O concentrations to 0.092 ± 0.008 ppm and 0.016 ± 0.001 ppm, respectively, approximately 3–4% of their respective concentrations in air. To avoid an alteration of sample concentration by variable residual gas levels left during a pre‐evacuation step, liquid and gaseous samples are injected into the N2 filled Exetainers. For gaseous samples where large volumes of gas are available, Exetainers can alternatively be flushed with 100 mL of sampling gas. For gaseous samples, measured CH4 and N2O concentrations of standard gases were statistically identical to their known concentrations. For liquid samples, measured CH4 and N2O concentrations of liquid standard dilution series showed strong linear correlations with theoretically calculated concentrations (slope CH4: 1.04, slope N2O: 1.12). Sample concentrations remained constant over a minimum storage period of 6 weeks.

1 January 2016 in Estuarine, Coastal and Shelf Science
Verified
Journal Article
Closed access
KSKatrin Sturm
Katrin Sturm
AGAlistair Grinham
Alistair Grinham
UWUrsula Werner
Ursula Werner
ZYZhiguo Yuan
Zhiguo Yuan

1 June 2017 in Estuarine, Coastal and Shelf Science
Verified
Journal Article
Closed access
KSKatrin Sturm
Katrin Sturm
UWUrsula Werner
Ursula Werner
AGAlistair Grinham
Alistair Grinham
ZYZhiguo Yuan
Zhiguo Yuan

28 January 2022 in Environmental Modelling & Software
Verified
Journal Article
Closed access
SYSongyan Yu
Songyan Yu
KSKatrin Sturm
Katrin Sturm
BGBadin Gibbes
Badin Gibbes
MKMark J. Kennard
Mark J. Kennard
CVCameron J. Veal
Cameron J. Veal
DHDavid P. Hamilton
David P. Hamilton

19 November 2025
Verified
Other
Open access
JDJohannes Dittmann
Johannes Dittmann
Damien MaherDamien Maher
Damien Maher
SJScott G. Johnston
Scott G. Johnston
DTDouglas R. Tait
Douglas R. Tait
PAPaula Gomez Alvarez
Paula Gomez Alvarez
LJLuke C. Jeffrey
Luke C. Jeffrey