Kevin Alexander Leyton Valencia

Mr. Kevin Alexander Leyton Valencia

Universidad del Valle, Santiago de Cali, Colombia
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2026 in Sci
Verified
Journal Article
Open access
PDF file
CMCésar Augusto Marín Moreno
César Augusto Marín Moreno
Kevin Alexander Leyton ValenciaKevin Alexander Leyton Valencia
Kevin Alexander Leyton Valencia
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
RBRubén Iván Bolaños
Rubén Iván Bolaños
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
The rapid growth of electric mobility is reshaping active distribution networks (ADNs), where electric vehicle charging stations (EVCS) introduce spatially concentrated, time-dependent, and highly simultaneous demand. This paper develops a network-oriented framework to evaluate EVCS integration in ADNs by coupling Colombian EV demand characterization, photovoltaic (PV) generation, battery energy storage system (BESS) operation, and AC power flow feasibility. The framework is applied to a 33-bus distribution feeder through four EVCS deployment cases and three support architectures: PV-only, PV–BESS colocated, and PV–BESS dispersed operation. The results show that non-coordinated EVCS deployment may increase losses, reduce voltage margins, and produce thermal overloads when feeder electrical sensitivity is ignored. They also reveal that optimized EVCS siting is insufficient under PV-only support, since PV generation lacks the controllability required to reshape feeder power flows during charging peaks. By contrast, BESS-assisted architectures substantially improve feeder operation, with dispersed storage achieving the best performance by decoupling charging demand locations from grid support locations. SOC and SOH analyses further demonstrate that storage feasibility and degradation must be assessed together with voltage, loading, and loss indicators. The proposed framework provides an operationally consistent basis for technically feasible EVCS planning in ADNs, linking local EV demand characterization, AC feasibility, support-architecture selection, and battery lifetime assessment.

12 August 2026 in Electricity
Verified
Journal Article
Open access
PDF file
Kevin Alexander Leyton ValenciaKevin Alexander Leyton Valencia
Kevin Alexander Leyton Valencia
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
Fiderman Machuca-MartinezFiderman Machuca-Martinez
Fiderman Machuca-Martinez
This paper presents an integrated day-ahead battery energy storage system (BESS) scheduling framework for radial active distribution networks with photovoltaic generation. Its main contribution is a reproducible evaluation chain combining non-ideal state-of-charge (SoC) feasibility correction, sequential AC power-flow verification, consistent metaheuristic benchmarking, and post-dispatch battery-aging analysis. The operating-cost objective coordinates hourly BESS active-power exchanges while enforcing storage and AC-network constraints. A parallel Coyote Optimization Algorithm (COA) is compared with parallel GWO, GA, PSO, and MVO implementations under a common formulation, correction procedure, evaluator, and computational environment. Validation uses modified 33-, 69-, and 136-bus radial feeders: 100 independent runs for the deterministic 33-bus benchmark, 100 independently optimized Monte Carlo scenarios for the 69-bus assessment, and seven representative daily profiles for the 136-bus weekly case. COA achieved an average cost reduction of 1.0084%, with the lowest dispersion of σ=0.0070%, in the 33-bus system; a mean scenario-wise reduction of 1.8337% in the 69-bus system; and a weekly reduction of 0.4402% in the 136-bus system. It obtained the lowest operating costs among the evaluated calibrated configurations, and all pairwise comparisons remained significant after Holm’s step-down adjustment applied separately within each system, although COA required greater computational effort than PSO. The reported schedules satisfied the imposed BESS and AC-network limits. Battery aging was evaluated only after scheduling and was not included in the optimization objective. The resulting cost-oriented schedules produced equivalent full-cycle values near 0.8 day−1 and projected 80% SoH lifetimes of approximately 6–8 years. These results provide an AC-feasible basis for comparing economic performance and post-dispatch battery-health implications under the evaluated conditions.

18 August 2026 in Sci
Verified
Journal Article
Open access
PDF file
DSDaniel Sanin-Villa
Daniel Sanin-Villa
Kevin Alexander Leyton ValenciaKevin Alexander Leyton Valencia
Kevin Alexander Leyton Valencia
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
Battery energy storage systems can reduce the operating cost of active distribution networks while supporting voltage control through their power electronic converters. This paper develops an application-specific multi-operator Differential Evolution (DE) framework for the coordinated active and reactive power scheduling of distributed battery energy storage systems in radial distribution networks with photovoltaic generation. The optimization model minimizes the daily operating cost associated with conventional energy supply, photovoltaic and storage operation and maintenance, and battery degradation. Candidate schedules encode hourly active and reactive power references for three storage converters, producing a 144 dimensional decision vector for a 24 h horizon. Each candidate is repaired to satisfy active power, state of charge, terminal energy, and converter apparent power limits before being evaluated through an alternating current power flow based on matrix successive approximations. The search framework generates three competing trial schedules per target individual by combining established best-guided, random, and current-to-random DE mutation families with a discrete parameter pool, a common feasibility-repair operator, and greedy selection after AC network evaluation. The method is tested on modified 33-node and 69-node active distribution networks and compared with AJAYA, genetic algorithm, multiverse optimizer, and particle swarm optimization. In the deterministic 33-node case, Differential Evolution obtains the lowest best cost, USD 6846.206, and the largest best cost reduction, 2.1838 percent. The scenario study performs separate deterministic optimizations for pre-generated operating realizations and is therefore interpreted as a scenario-conditioned sensitivity assessment rather than as stochastic or robust optimization of one here-and-now schedule. In this assessment, DE achieves the largest average savings: 2.3487 percent in the 33-node network and 2.9314 percent in the 69-node network. Voltage magnitudes, branch loading, converter ratings, and cyclic state of charge constraints are satisfied in all evaluated cases. The results identify the proposed framework as a competitive day-ahead solver within the evaluated cases, while no claim of global optimality or universal superiority over alternative optimizers is made.

30 September 2026 in Results in Engineering
Verified
Journal Article
Open access
CMCésar Augusto Marín Moreno
César Augusto Marín Moreno
Kevin Alexander Leyton ValenciaKevin Alexander Leyton Valencia
Kevin Alexander Leyton Valencia
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
RBRubén Iván Bolaños
Rubén Iván Bolaños
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández

22 September 2026 in Journal of Energy Storage
Verified
Journal Article
Open access
Kevin Alexander Leyton ValenciaKevin Alexander Leyton Valencia
Kevin Alexander Leyton Valencia
LGLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo

2 November 2026 in Sci
Verified
Journal Article
Open access
PDF file
Kevin Alexander Leyton ValenciaKevin Alexander Leyton Valencia
Kevin Alexander Leyton Valencia
Luis Fernando Grisales-NoreñaLuis Fernando Grisales-Noreña
Luis Fernando Grisales-Noreña
VBVanessa Botero-Gómez
Vanessa Botero-Gómez
Oscar Danilo Montoya GiraldoOscar Danilo Montoya Giraldo
Oscar Danilo Montoya Giraldo
DSDaniel Sanin-Villa
Daniel Sanin-Villa
The increasing penetration of distributed energy resources requires battery energy storage systems (BESSs) to be scheduled economically while preserving network security and accounting for battery-life consumption. This work’s primary technical contribution is an integrated, degradation-aware framework for coordinated day-ahead active–reactive power dispatch of multiple BESS units in active distribution networks. The formulation minimizes grid-energy purchases, PV and BESS operation and maintenance costs, and monetized cycling and calendar degradation while enforcing nonlinear AC power-flow equations, voltage and branch-current limits, converter apparent-power capability, non-ideal state-of-charge dynamics, and terminal-energy requirements. Each candidate 24-h SoC trajectory is processed through a Rainflow-based semi-empirical aging model, allowing degradation to be included directly in the fitness evaluation. SELGO is employed as the optimization engine and coupled with a parallel successive-approximation AC power-flow evaluator. The framework is assessed through 100 independent executions under deterministic operating conditions and 100 stochastic demand and PV-generation scenarios in a modified 33-bus system, together with 100 stochastic scenarios in a modified 69-bus system. SELGO is compared with AJAYA, GA, MVO, PSO, and TDE under equivalent models, constraints, scenarios, and parameter-tuning conditions. Among the evaluated methods, SELGO yields the smallest mean operating cost for each of the three analyzed cases, reducing the corresponding base costs by 2.2015%, 2.4017%, and 3.0108%, respectively, while satisfying voltage, thermal, converter, and inter-temporal BESS constraints. The cumulative ablation analysis also supports the conditional benefit of the complete SELGO architecture. Across the analyzed cases, cycling intensity ranges from 0.7690 to 0.8386 EFC/day and daily aging from 6.4864×10−5 to 7.5160×10−5 day−1. Under the repeated-day assumption, the 80% SoH threshold is reached after 5.9756–6.9238 years, whereas the corresponding interval for 70% SoH is 10.8433–12.5639 years; these values are intended for comparative aging interpretation rather than as field-life predictions. The results show that the framework identifies low-cost, AC-feasible schedules while explicitly quantifying the associated battery-life consumption.