Khurram Karim Qureshi

Prof. Khurram Karim Qureshi

King Fahd University of Petroleum and Minerals, Dhahran, Ash Sharqīyah, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2011 in Optics Letters
Verified
Journal Article
Closed access
PDF file
CWChuang Wu
Chuang Wu
HFH. Y. Fu
H. Y. Fu
Khurram Karim QureshiKhurram Karim Qureshi
Khurram Karim Qureshi
BGBai-Ou Guan
Bai-Ou Guan
HTH. Y. Tam
H. Y. Tam
A fiber-optic Fabry–Perot interferometer was constructed by splicing a short length of photonic crystal fiber to a standard single-mode fiber. The photonic crystal fiber functions as a Fabry–Perot cavity and serves as a direct sensing probe without any additional components. Its pressure and temperature responses in the range of 0–40MPa and 25°C–700°C were experimentally studied. The proposed sensor is easy to fabricate, potentially low- cost, and compact in size, which makes it very attractive for high-pressure and high-temperature sensing applications.

10 March 2021 in IEEE Access
Verified
Journal Article
Open access
AKAwais Khan
Awais Khan
shahid bashirshahid bashir
shahid bashir
Salman GhafoorSalman Ghafoor
Salman Ghafoor
Khurram Karim QureshiKhurram Karim Qureshi
Khurram Karim Qureshi
This paper presents a compact, uni-planer wide band Multiple-Input-Multiple-Output (MIMO) antenna. The designed antenna array has a compact size of (26mm x 31mm) covering a wide frequency band from 3.1GHz - 11GHz. A partial ground plane shared by two radiating patches is used. A ground stub and a single column Electromagnetic Bandgap (EBG) structure in between the two radiating patches results in very low mutual coupling in the designed antenna. The proposed MIMO-antenna was evaluated through different performance metric indicators like channel capacity loss, far-field radiation pattern, S-parameters, envelope correlation coefficient, peak gain, diversity-gain and radiation efficiency. Our designed MIMO antenna has a very high isolation amongst the MIMO antennas ( $\text{S}_{21} < -25$ dB), a high Diversity-Gain (DG $>9.995$ dB), a very low Envelope Co-relation Coefficient of (ECC < 0.001) and low Channel-Capacity-Loss (CCL < 0.1bits/s/Hz). The said antenna has an average radiation efficiency of 85.5% and a peak gain of (5.67dB) within the ultra-wideband (UWB) spectrum. A 0.8mm thick FR-4 substrate is used to fabricate the MIMO-antenna and tested in an anechoic chamber. The measured results closely match with the simulated results.

24 March 2023 in IEEE Access
Verified
Journal Article
Open access
AHAbdullah Mohammad Tanvirul Hoque
Abdullah Mohammad Tanvirul Hoque
KAKusay Faisal Al-Tabatabaie
Kusay Faisal Al-Tabatabaie
EAEakub Ali
Eakub Ali
ABAsad Muhammad Butt
Asad Muhammad Butt
SISheikh Sharif Iqbal
Sheikh Sharif Iqbal
AAAsad Arshad
Asad Arshad
Point-of-care (POC) diagnostic medical devices require simple but sensitive and inclusive detection capabilities. This study develops a unique photonic crystal fiber-based surface plasmon resonance (PCF-SPR) sensor that uses a u-grooved selective coating for extremely sensitive remote and biosensing applications. Scale-down (SCD) air holes control the path that incoming light takes through the sensor in order to activate the free electrons that are present there. To reduce outward radiation, perfectly matched layers (PML) of the absorbing boundary are integrated in addition to optimizing the structural geometry and material thickness. The Finite Element Method (FEM) is employed to quantitatively tune the properties of light directing and sensitivity of the proposed sensor. The proposed sensor has the maximum amplitude sensitivity (AS) of 1189 RIU -1 , the highest wavelength sensitivity (WS) of 12,500 nm/(RIU), and an outstanding resolution of 8.0×10 -6 RIU. The constructed model covers a large refractive index (RI) range of unknown samples, ranging from 1.29 to 1.40. This range allows this sensor to cover the detection of a wide range of bio-analytics, including viruses, cancer cells, carbohydrates, proteins, and DNA/RNA etc. We strongly believe that the suggested sensor will play an extremely useful role in the detection of POC bio-sample detection.

1 November 2013 in Optics Communications
Verified
Journal Article
Closed access
Khurram Karim QureshiKhurram Karim Qureshi
Khurram Karim Qureshi
Zhengyong LiuZhengyong Liu
Zhengyong Liu
HTHwa-Yaw Tam
Hwa-Yaw Tam
Muhammad Fahad ZiaMuhammad Fahad Zia
Muhammad Fahad Zia

2 April 2003 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
LCL.Y. Chan
L.Y. Chan
Khurram Karim QureshiKhurram Karim Qureshi
Khurram Karim Qureshi
PWPing-kong Alexander Wai
Ping-kong Alexander Wai
BMB. Moses
B. Moses
LLL.F.K. Lui
L.F.K. Lui
MDM.S. Demokan
M.S. Demokan
A novel all-optical bit-error monitoring system is demonstrated by cascading two all-optical logic gates: an inverted wavelength converter and an optical NOR gate which are realized using injection-locked laser diodes operating at different thresholds. Real-time optical monitoring signal is generated which indicates the positions and duration of both bit and burst errors in 10-Gb/s nonreturn-to-zero signals.

13 October 2021 in Optical Review
Verified
Journal Article
Closed access
PDF file
Muhammad Jawad MirzaMuhammad Jawad Mirza
Muhammad Jawad Mirza
Salman GhafoorSalman Ghafoor
Salman Ghafoor
NHNazish Habib
Nazish Habib
FKFirdos Kanwal
Firdos Kanwal
Khurram Karim QureshiKhurram Karim Qureshi
Khurram Karim Qureshi