Bin Yang

Dr. Bin Yang

Medical Physics Department, Hong Kong Sanatorium and Hospital, Hong Kong, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2021 in Cancers
Verified
Journal Article
Open access
PDF file
DPDarren M. C. Poon
Darren M. C. Poon
JYJing Yuan
Jing Yuan
OWOi-Lei Wong
Oi-Lei Wong
Bin YangBin Yang
Bin Yang
SCSin-Ting Chiu
Sin-Ting Chiu
SYSiu-Ki Yu
Siu-Ki Yu
Background: Magnetic resonance-guided stereotactic body radiotherapy (MRgSBRT) offers the potential for achieving better prostate cancer (PC) treatment outcomes. This study reports the preliminary clinical results of 1.5T MRgSBRT in localized PC, based on both clinician-reported outcome measurement (CROM) and patient-reported outcome measurement (PROM). Methods: Fifty-one consecutive localized PC patients were prospectively enrolled with a median follow-up of 199 days. MRgSBRT was delivered in five fractions of 7.25–8 Gy with daily online adaptation. Clinician-reported gastrointestinal (GI) and genitourinary (GU) adverse events based on the Common Terminology Criteria for Adverse Events (CTCAE) Scale v. 5.0 were assessed. The Expanded Prostate Cancer Index Composite Questionnaire was collected at baseline, 1 month, and every 3 months thereafter. Serial prostate-specific antigen measurements were longitudinally recorded. Results: The maximum cumulative clinician-reported grade ≥ 2 acute GU and GI toxicities were 11.8% (6/51) and 2.0% (1/51), respectively, while grade ≥ 2 subacute GU and GI toxicities were 2.3% (1/43) each. Patient-reported urinary, bowel, and hormonal domain summary scores were reduced at 1 month, then gradually returned to baseline levels, with the exception of the sexual domain. Domain-specific subscale scores showed similar longitudinal changes. All patients had early post-MRgSBRT biochemical responses. Conclusions: The finding of low toxicity supports the accumulation of clinical evidence for 1.5T MRgSBRT in localized PC.

2 September 2021 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
Bin YangBin Yang
Bin Yang
KTK K Tang
K K Tang
HGH Geng
H Geng
WLW W Lam
W W Lam
YWY S Wong
Y S Wong
SYS K Yu
S K Yu
Synchrony Respiratory Tracking system adapted from CyberKnife has been introduced in Radixact to compensate the tumor motion caused by respiration. This study aims to compare the modeling accuracy of the Synchrony system between Radixact and CyberKnife. Two Synchrony plans based on fiducial phantoms were created for CyberKnife and Radixact, respectively. Different respiratory motion traces were used to drive a motion platform to move along the superoinferior and left-right direction. The cycle time and the amplitude of target/surrogate motion of one selected motion trace were scaled to investigate the dependence of modeling accuracy on the motion characteristic. The predicted target position, the correlation error, potential difference (Radixact only) and standard error (CyberKnife only) were extracted from raw data or log files of the two systems. The modeling accuracy was evaluated by calculating the root-mean-square (RMS) error between the predicted target positions and the input motion trace. A threshold T95 within which 95% of the potential difference or the standard error lay was defined and evaluated. Except for the motion trace with a small amplitude and a good (linear) correlation between target and surrogate motion, Radixact showed smaller RMS errors than CyberKnife. The RMS error of both systems increased with the motion amplitude and showed a decreasing trend with the increasing cycle time. No correlation was found between the RMS error and the amplitude of surrogate motion. T95 could be a good estimator of modeling accuracy for CyberKnife rather than Radixact. The correlation error defined in Radixact were largely affected by the number of fiducial markers and the setup error. In general, the modeling accuracy of the Radixact Synchrony system is better than that of the CyberKnife Synchrony system under unfavorable conditions.

18 July 2022 in Cancers
Verified
Journal Article
Open access
PDF file
DPDarren M. C. Poon
Darren M. C. Poon
JYJing Yuan
Jing Yuan
Bin YangBin Yang
Bin Yang
OWOi Lei Wong
Oi Lei Wong
SCSin-Ting Chiu
Sin-Ting Chiu
RYRaymond W. H. Yung
Raymond W. H. Yung
Background: Conventionally fractionated whole-pelvic nodal radiotherapy (WPRT) improves clinical outcome compared to prostate-only RT in high-risk prostate cancer (HR-PC). MR-guided stereotactic body radiotherapy (MRgSBRT) with concomitant WPRT represents a novel radiotherapy (RT) paradigm for HR-PC, potentially improving online image guidance and clinical outcomes. This study aims to report the preliminary clinical experiences and treatment outcome of 1.5 Tesla adaptive MRgSBRT with concomitant WPRT in HR-PC patients. Materials and methods: Forty-two consecutive HR-PC patients (72.5 ± 6.8 years) were prospectively enrolled, treated by online adaptive MRgSBRT (8 Gy(prostate)/5 Gy(WPRT) × 5 fractions) combined with androgen deprivation therapy (ADT) and followed up (median: 251 days, range: 20–609 days). Clinical outcomes were measured by gastrointestinal (GI) and genitourinary (GU) toxicities according to the Common Terminology Criteria for Adverse Events (CTCAE) Scale v. 5.0, patient-reported quality of life (QoL) with EPIC (Expanded Prostate Cancer Index Composite) questionnaire, and prostate-specific antigen (PSA) responses. Results: All MRgSBRT fractions achieved planning objectives and dose specifications of the targets and organs at risk, and they were successfully delivered. The maximum cumulative acute GI/GU grade 1 and 2 toxicity rates were 19.0%/81.0% and 2.4%/7.1%, respectively. The subacute (>30 days) GI/GU grade 1 and 2 toxicity rates were 21.4%/64.3% and 2.4%/2.4%, respectively. No grade 3 toxicities were reported. QoL showed insignificant changes in urinary, bowel, sexual, and hormonal domain scores during the follow-up period. All patients had early post-MRgSBRT biochemical responses, while biochemical recurrence (PSA nadir + 2 ng/mL) occurred in one patient at month 18. Conclusions: To our knowledge, this is the first prospective study that showed the clinical outcomes of MRgSBRT with concomitant WPRT in HR-PC patients. The early results suggested favorable treatment-related toxicities and encouraging patient-reported QoLs, but long-term follow-up is needed to confirm our early results.

30 April 2021 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
Bin YangBin Yang
Bin Yang
YWYeung Sum Wong
Yeung Sum Wong
WLWai Wang Lam
Wai Wang Lam
HGHui Geng
Hui Geng
CHChen Yu Huang
Chen Yu Huang
SYSiu Ki Yu
Siu Ki Yu
Purpose . This study aims to evaluate the performance of a commercial 1.5 T MR-Linac by analyzing its patient-specific quality assurance (QA) data collected during one full year of clinical operation. Methods and Materials . The patient-specific QA system consisted of offline delivery QA (DQA) and online calculation-based QA. Offline DQA was based on ArcCHECK-MR combined with an ionization chamber. Online QA was performed using RadCalc that calculated and compared the point dose calculation with the treatment planning system (TPS). A total of 24 patients with 189 treatment fractions were enrolled in this study. Gamma analysis was performed and the threshold that encompassed 95% of QA results (T95) was reported. The plan complexity metric was calculated for each plan and compared with the dose measurements to determine whether any correlation existed. Results . All point dose measurements were within 5% deviation. The mean gamma passing rates of the group data were found to be 96.8 ± 4.0% and 99.6 ± 0.7% with criteria of 2%/2mm and 3%/3mm, respectively. T95 of 87.4% and 98.2% was reported for the overall group with the two passing criteria, respectively. No statistically significant difference was found between adaptive treatments with adapt-to-position (ATP) and adapt-to-shape (ATS), whilst the category of pelvis data showed a better passing rate than other sites. Online QA gave a mean deviation of 0.2 ± 2.2%. The plan complexity metric was positively correlated with the mean dose difference whilst the complexity of the ATS cohort had larger variations than the ATP cohort. Conclusions . A patient-specific QA system based on ArcCHECK-MR, solid phantom and ionization chamber has been well established and implemented for validation of treatment delivery of a 1.5 T MR-Linac. Our QA data obtained over one year confirms that good agreement between TPS calculation and treatment delivery was achieved.

1 January 2022 in Practical Radiation Oncology
Verified
Journal Article
Closed access
Bin YangBin Yang
Bin Yang
JYJing Yuan
Jing Yuan
KCKin Yin Cheung
Kin Yin Cheung
CHChen-Yu Huang
Chen-Yu Huang
DPDarren M.C. Poon
Darren M.C. Poon
SYSiu Ki Yu
Siu Ki Yu

1 January 2019 in Medical Dosimetry
Verified
Journal Article
Closed access
Bin YangBin Yang
Bin Yang
HGHui Geng
Hui Geng
YDYing Ding
Ying Ding
CKChi Wah Kong
Chi Wah Kong
CCChi Wai Cheung
Chi Wai Cheung
SYSiu Ki Yu
Siu Ki Yu