Objectives: To investigate the influence of kernels and iterative reconstructions on pericoronary adipose tissue (PCAT) attenuation in coronary CT angiography (CCTA). Materials and methods: Twenty otherwise healthy subjects (16 females; median age 52 years) with atypical chest pain, low risk of coronary artery disease (CAD), and without CAD in photon-counting detector CCTA were included. Images were reconstructed with a quantitative smooth (Qr36) and three vascular kernels of increasing sharpness levels (Bv36, Bv44, Bv56). Quantum iterative reconstruction (QIR) was either switched-off (QIRoff) or was used with strength levels 2 and 4. The fat-attenuation-index (FAI) of the PCAT surrounding the right coronary artery was calculated in each dataset. Histograms of FAI measurements were created. Intra- and inter-reader agreements were determined. A CT edge phantom was used to determine the edge spread function (ESF) for the same datasets. Results: Intra- and inter-reader agreement of FAI was excellent (intra-class correlation coefficient = 0.99 and 0.98, respectively). Significant differences in FAI were observed depending on the kernel and iterative reconstruction strength level (each, p < 0.001), with considerable inter-individual variation up to 34 HU and intra-individual variation up to 33 HU, depending on kernels and iterative reconstruction levels. The ESFs showed a reduced range of edge-smoothing with increasing kernel sharpness, causing an FAI decrease. Histogram analyses revealed a narrower peak of PCAT values with increasing iterative reconstruction levels, causing a FAI increase. Conclusions: PCAT attenuation determined with CCTA heavily depends on kernels and iterative reconstruction levels both within and across subjects. Standardization of CT reconstruction parameters is mandatory for FAI studies to enable meaningful interpretations. Key Points: QuestionDo kernels and iterative reconstructions influence pericoronary adipose tissue (PCAT) attenuation in coronary CT angiography (CCTA)?FindingsSignificant differences in fat-attenuation-index (FAI) were observed depending on the kernel and iterative reconstruction strength level with considerable inter- and intra-individual variation.Clinical relevancePCAT attenuation heavily depends on kernels and iterative reconstructions requiring CT reconstruction parameter standardization to enable meaningful interpretations of fat-attenuation differences across subjects.
6 September 2024 in The International Journal of Cardiovascular Imaging
Non-invasive imaging with characterization and quantification of the myocardium with computed tomography (CT) became feasible owing to recent technical developments in CT technology. Cardiac CT can serve as an alternative modality when cardiac magnetic resonance imaging and/or echocardiography are contraindicated, not feasible, inconclusive, or non-diagnostic. This review summarizes the current and potential future role of cardiac CT for myocardial characterization including a summary of late enhancement techniques, extracellular volume quantification, and strain analysis. In addition, this review highlights potential fields for research about myocardial characterization with CT to possibly include it in clinical routine in the future. Graphical Abstract Cardiac computed tomography as an increasingly important alternative for myocardial tissue characterization and functional assessment.
1 November 2024 in American Journal of Roentgenology
Background: Pericoronary adipose tissue (PCAT) attenuation and fat attenuation index (FAI) may serve as markers of inflammation and risk of adverse cardiac events. However, standardization of relevant CT acquisition and reconstruction parameters is lacking. Objective: To investigate the influence of vessel attenuation, virtual monoenergetic image (VMI) level, and reconstruction kernel on PCAT attenuation and FAI using energy-integrating detector (EID) and photon-counting detector (PCD) CT systems in an ex-vivo porcine heart model. Methods: A porcine heart's right coronary artery (RCA) was injected with saline or varying contrast media dilutions to achieve vessel attenuations ranging from 0 to 1000 HU. After each injection, the heart was scanned with EID CT at 120 kVp and PCD CT at 140 kVp, at constant CTDIvol (10 mGy). For EID CT, polychromatic images were reconstructed with Qr40 kernel. For PCD CT, VMI (40-80 keV at 10-keV increments) were reconstructed with Qr40, Bv40, and Bv56 kernels. ROIs were placed to measure RCA and PCAT attenuation. FAI was determined using software; histogram analysis was performed of voxel attenuations in the volumes of interest for FAI calculation. Results: Correlations were observed between attenuation in the RCA and adjacent PCAT (r=0.3-1.0), and between vessel attenuation and FAI (r=-0.9-1.0). For PCAT attenuation and FAI, these associations became progressively weaker for progressively sharper kernels. For increasing vessel attenuation for EID CT and for increasing VMI level for PCD CT, FAI histograms showed right shifts of the peak attenuation; the percentage of histogram voxels meeting the threshold range for inclusion in FAI calculation for EID CT was 8-29% and for PCD CT at VMI levels of 70-80 keV was 5-42%. For PCD CT, sharper kernels were associated with left shifts in peak attenuations and greater percentages of voxels within the threshold range for inclusion in FAI calculations. Conclusion: PCAT attenuation and FAI are influenced by vessel lumen attenuation, VMI level, and reconstruction kernel. A minority of pericoronary voxels contribute to FAI measurements for polychromatic EID CT and for PCD CT at high VMI levels. Clinical Impact: These findings may help standardize acquisition and reconstruction parameters for PCAT attenuation and FAI measurements.
Epicardial adipose tissue (EAT) and pericardial adipose tissue (PAT) are increasingly recognized as distinct fat depots with implications for cardiovascular disease. This review discusses their anatomical and physiological characteristics, as well as their pathophysiological roles. EAT, in direct contact with the myocardium, exerts local inflammatory and metabolic effects on the heart, while PAT influences cardiovascular health rather systemically. We sought to discuss the currently used imaging modalities to assess these fat compartments—CT, MRI, and echocardiography—emphasizing their advantages, limitations, and the urgent need for standardization for both scanning and image reconstruction. Advances in image segmentation, particularly deep learning-based approaches, have improved the accuracy and reproducibility of EAT and PAT quantification. This review also explores the role of EAT and PAT as risk factors for cardiovascular outcomes, summarizing conflicting evidence across studies. Finally, we summarize the effects of medical therapy and lifestyle interventions on reducing EAT volume. Understanding and accurately quantifying EAT and PAT is essential for cardiovascular risk stratification and may open new pathways for therapeutic interventions.
Objectives: Severe coronary artery calcification leads to blooming artifacts in conventional coronary CT angiography (CCTA), which may reduce diagnostic accuracy. Ultra-high resolution (UHR) photon-counting detector CT (PCD-CT) reduces calcium blooming. This study aimed to evaluate the diagnostic performance of UHR CCTA with PCD-CT for detecting coronary stenoses in patients with a high coronary calcium burden compared to invasive coronary angiography (ICA). Materials and methods: In this IRB-approved single-center study, patients with Agatston scores > 600 were included, who underwent ICA and coronary UHR PCD-CT angiography within 2 months. 94% of patients underwent CT prior to transcatheter aortic valve replacement. Coronary arteries were graded for diameter stenosis severity (> 50, > 70%) by two blinded, independent readers. Accuracy, sensitivity, and specificity of CCTA were calculated using ICA as the reference standard. Subgroup analyses were performed across Agatston score groups (600–999, 1000–1999, 2000–2999, and > 3000). Results: 62 patients (mean age, 76 ± 9 years, 16 women) were included. The median Agatston score was 2423 (IQR: 1085–3340). Across all Agatston categories, CCTA demonstrated high diagnostic accuracy and strong agreement with ICA (Cohen’s kappa 0.71–1.00). In patients with Agatston scores > 3000 ( n = 18), the diagnostic performance of coronary UHR PCD-CT angiography for detecting > 50% (sensitivity 92–100%, specificity 83–100%) and > 70% diameter stenosis (sensitivity 88–100%, specificity 89–100%) remained high for both readers. There was no correlation between the Agatston score and diagnostic error ( p > 0.05). Conclusion: UHR CCTA with PCD-CT provides high diagnostic performance even in patients with extensive coronary calcifications. Key Points: QuestionIn patients with severe coronary calcification, conventional coronary CT angiography often suffers from blooming artifacts, reducing accuracy and causing unnecessary invasive procedures.FindingsUltra-high resolution coronary angiography with photon-counting detector CT showed high sensitivity and specificity for detecting stenoses, even at Agatston scores > 3000.Clinical relevanceUltra-high resolution coronary CT angiography enables accurate noninvasive detection of stenoses in heavily calcified vessels, potentially reducing invasive coronary angiography. Graphical
Objectives: This study aimed to assess the feasibility of left ventricular myocardial characterization in patients with ventricular arrhythmias using late enhancement (LE) photon-counting detector computed tomography (PCD-CT) scans, in comparison with invasive endocardial electroanatomical mapping (EAM). Materials and methods: This single-center retrospective observational study included 20 patients (mean age 64 ± 8 years, 4 female) who underwent PCD-CT prior to 3D endocardial uni- and bipolar EAM and radiofrequency catheter ablation (RFCA) between May 2022 and February 2024. Sixteen patients (80%) had cardiac implantable electronic devices. Twelve (60%) had ischemic and 8 (40%) had non-ischemic cardiomyopathy. Pathologic myocardial segments were defined by low-voltage electrograms < 5 mV in unipolar and < 0.5 mV in bipolar maps. Cardiac scans included LE acquisitions 5 min after contrast injection in the ECG-triggered sequential mode. Myocardial extracellular volume was computed from cardiac LE scans and visualized as polar and atlas maps (the latter depicting wall thickness) to identify pathologic segments with fibrosis and/or scar. LE scans were compared with EAM. Results: In patients with ischemic cardiomyopathy, agreement of pathologic segments on CT was good with unipolar EAM (κ = 0.655 ± 0.249), and moderate with bipolar EAM (κ = 0.547 ± 0.267). In patients with non-ischemic cardiomyopathy, agreement of pathologic segments on CT was moderate compared with unipolar (κ = 0.455 ± 0.356) and fair with bipolar EAM (κ = 0.255 ± 0.260). Conclusions: Preliminary evidence suggests that characterization of pathologic myocardial segments using LE PCD-CT scans is feasible and yields good agreement with endocardial EAM, particularly when compared with unipolar EAM and in patients with ischemic cardiomyopathy. Critical relevance statement: Characterization of pathologic left ventricular segments using myocardial extracellular volume and thickness representations from spectral late enhancement photon-counting detector CT scans indicates good agreement with unipolar endocardial electroanatomical mapping, particularly in patients with ischemic cardiomyopathy. Key Points: Cardiac late enhancement imaging with photon-counting detector CT may enable characterization of pathologic myocardial segments in ventricular arrhythmia. Myocardial extracellular volume and thickness representations yield good agreement with unipolar endocardial electroanatomical mapping, particularly in patients with ischemic cardiomyopathy. Left ventricular myocardial characterization is feasible with late enhancement photon-counting detector CT and may complement invasive radiofrequency catheter ablations. Graphical