Kraingkrai Ponhong

Dr. Kraingkrai Ponhong

Mahasarakham University, Maha Sarakham, Thailand
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

27 October 2023 in Food Chemistry
Verified
Journal Article
Closed access
TNTammanoon Nilnit
Tammanoon Nilnit
JJJanjira Jeenno
Janjira Jeenno
SSSam-ang Supharoek
Sam-ang Supharoek
JVJitlada Vichapong
Jitlada Vichapong
WSWatsaka Siriangkhawut
Watsaka Siriangkhawut
KPKraingkrai Ponhong
Kraingkrai Ponhong

1 December 2015 in Journal of Food and Drug Analysis
Verified
Journal Article
Open access
KPKraingkrai Ponhong
Kraingkrai Ponhong
SSSam-Ang Supharoek
Sam-Ang Supharoek
WSWatsaka Siriangkhawut
Watsaka Siriangkhawut
KGKate Grudpan
Kate Grudpan
A simple, rapid, and sensitive spectrophotometric method for the determination of benzoyl peroxide (BPO) in wheat flour samples was developed. The detection principle is based on BPO reacted with 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) to obtain a blue-green colored product that was detected at 415 nm by spectrophotometry. The effect of factors influencing the color reaction was investigated. Under the selected conditions, the linear range for quantification of BPO was observed between 0.2-1.0 mg L-1 with r2 = 0.998. The limit of detection (LOD) was 0.025 mg L-1. The developed method obtained superior precision (relative standard deviation < 2%) using 11 repeatability at 0.2 mg L-1, 0.6 mg L-1, and 0.8 mg L-1. The proposed methodology was successfully applied to determine BPO in wheat flour samples.

1 April 2018 in Journal of Food and Drug Analysis
Verified
Journal Article
Open access
SSSam-Ang Supharoek
Sam-Ang Supharoek
KPKraingkrai Ponhong
Kraingkrai Ponhong
WSWatsaka Siriangkhawut
Watsaka Siriangkhawut
KGKate Grudpan
Kate Grudpan
A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid-base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base and indicator, respectively. Mixing lime and turmeric produced an orange to reddish-brown color solution which absorbed the maximum wavelength at 455 nm, with absorbance decreasing with increasing acetic acid concentration. Influential parameters including lime and turmeric concentrations, reagent and sample aspirated volumes, mixing coil length and dispensing flow rate were investigated and optimized. A standard calibration graph was plotted for 0-5.0 mmol/L acetic acid with r2 = 0.9925. Relative standard deviations (RSD) at 2.0 and 4.0 mmol/L acetic acid were less than 3% (n = 7), with limit of detection (LOD) and limit of quantification (LOQ) at 0.12 and 0.24 mmol/L, respectively. The method was successfully applied to assay acetic acid concentration in cooking vinegar samples. Results achieved were not significantly different from those obtained following a batchwise standard AOAC titration method.

10 November 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
PDPirom Didpinrum
Pirom Didpinrum
WSWatsaka Siriangkhawut
Watsaka Siriangkhawut
KPKraingkrai Ponhong
Kraingkrai Ponhong
PCPiyanete Chantiratikul
Piyanete Chantiratikul
Kate GrudpanKate Grudpan
Kate Grudpan
A low-cost and reliable analytical method based on the combination of a newly designed sticker-plastic sheet platform, digital image-based colorimetry and down scaled Kjeldahl digestion is proposed for the determination of protein content in food samples. The yellowish-brown colloidal products, obtained from the reaction between the ammonium–nitrogen after digestion and the working Nessler's reagent on the miniaturized sticker-plastic sheet platform, were captured for imaging with a smartphone camera. The operational parameters and reaction conditions were optimized. A down scaled Kjeldahl digestion procedure was performed using the newly designed digestion block. The parameters influencing the digestion efficiency, including the mass of the sample, volume of acid, mass of the catalyst and digestion time, were evaluated. Under the selected conditions, a linear calibration in the range of 5–60 mg L−1 ammonium–nitrogen was obtained with limits of detection and quantification of 2.8 and 7.6 mg L−1, respectively. The repeatability and reproducibility were 6.7% and 8.8%, respectively. The accuracy of the proposed method was evaluated by applying the developed procedure for milk powder and feeding stuff reference materials and comparing it with the conventional Kjeldahl method. The proposed method was successfully applied for the determination of protein contents in soy foods and protein-based foods. The results agreed well with those obtained from the conventional Kjeldahl method.

1 January 2019 in Microchemical Journal
Verified
Journal Article
Closed access
SSSam-Ang Supharoek
Sam-Ang Supharoek
KPKraingkrai Ponhong
Kraingkrai Ponhong
WSWatsaka Siriangkhawut
Watsaka Siriangkhawut
KGKate Grudpan
Kate Grudpan