Laura Joyce

Dr. Laura Joyce

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2006 in American Journal of Medical Genetics Part B: Neuropsychiatric Genetics
Verified
Journal Article
Closed access
PDF file
KLKatrina J. Light
Katrina J. Light
PJPeter R. Joyce
Peter R. Joyce
SLSuzanne E. Luty
Suzanne E. Luty
RMRoger T. Mulder
Roger T. Mulder
CFChristropher M.A. Frampton
Christropher M.A. Frampton
MKMartin Alexander Kennedy
Martin Alexander Kennedy

20 October 2020 in Emergency Medicine Australasia
Verified
Journal Article
Open access
PDF file
LJLaura Joyce
Laura Joyce
SRSandra K Richardson
Sandra K Richardson
AMAndrew McCombie
Andrew McCombie
GHGreg J Hamilton
Greg J Hamilton
MAMichael W Ardagh
Michael W Ardagh
Objective: To describe mental health presentations to a tertiary ED in New Zealand during a national COVID‐19 lockdown.Methods: A retrospective, comparative cohort study in Christchurch Hospital, New Zealand.Results: There was a 3510 (37%)‐patient decrease in all presentations to Christchurch Hospital ED during the 5‐week COVID‐19 lockdown period from 26 March 2020 to 28 April 2020, compared to a 111 (1.2%)‐patient decrease in the same time period in the previous year (P < 0.00001). There is usually a seasonal reduction in mental health attendances at this time of year compared to the weeks before. In 2019, there was a 49 (9.8%)‐patient reduction in mental health presentations, whereas in 2020 there was a 193 (34%)‐patient reduction (P < 0.001). In 2020, the proportion of mental health attendances compared to all ED attendances during the 5‐week lockdown period was similar to the 5‐week pre‐lockdown period (564/9460 vs 371/5950, P = 0.48). The proportion of mental health patients presenting due to overdose increased by 6.5% (158/564 vs 128/371, P = 0.035); those due to self‐harm increased by 3.5% (35/564 vs 36/371, P = 0.049). The proportion of mental health presentations due to anxiety, depression and other non‐self‐harm/overdose complaints decreased by 10% (371/564 vs 207/371, P = 0.002). The proportion of overdoses of paracetamol and ibuprofen increased by 13.4% during lockdown (22/158 vs 35/128, P = 0.005).Conclusions: During the COVID‐19 lockdown, both overall ED presentations as well as mental health‐related presentations decreased. There was a relative increase in overdoses and self‐harm, particularly involving paracetamol and ibuprofen.

9 August 2021 in JACEP Open
Verified
Journal Article
Open access
PDF file
KSKim Schwab
Kim Schwab
DNDacloc Nguyen
Dacloc Nguyen
GUGilAnthony Ungab
GilAnthony Ungab
GFGregory Feld
Gregory Feld
AMAlan S. Maisel
Alan S. Maisel
WPW. Frank Peacock
W. Frank Peacock
Objective Advanced machine learning technology provides an opportunity to improve clinical electrocardiogram (ECG) interpretation, allowing non-cardiology clinicians to initiate care for atrial fibrillation (AF). The Lucia Atrial Fibrillation Application (Lucia App) photographs the ECG to determine rhythm detection, calculates CHA2DS2-VASc and HAS-BLED scores, and then provides guideline-recommended anticoagulation. Our purpose was to determine the rate of accurate AF identification and appropriate anticoagulation recommendations in emergency department (ED) patients ultimately diagnosed with AF. Methods We performed a single-center, observational retrospective chart review in an urban California ED, with an annual census of 70,000 patients. A convenience sample of hospitalized patients with AF as a primary or secondary discharge diagnosis were evaluated for accurate ED AF diagnosis and ED anticoagulation rates. This was done by comparing the Lucia App against a gold standard board-certified cardiologist diagnosis and using the American College of Emergency Physicians AF anticoagulation guidelines. Results Two hundred and ninety seven patients were enrolled from January 2016 until December 2019. The median age was 79 years and 44.1% were female. Compared to the gold standard diagnosis, the Lucia App detected AF in 98.3% of the cases. Physicians recommended guideline-consistent anticoagulation therapy in 78.5% versus 98.3% for the Lucia App. Of the patients with indications for anticoagulation and discharged from the ED, only 25.0% were started at discharge. Conclusion Use of a cloud-based ECG identification tool can allow non-cardiologists to achieve similar rates of AF identification as board-certified cardiologists and achieve higher rates of guideline-recommended anticoagulation therapy in the ED.

15 January 2021 in Journal of Paediatrics and Child Health
Verified
Journal Article
Closed access
PDF file
RBRoshit K Bothara
Roshit K Bothara
ARAditya Raina
Aditya Raina
BCBrennan Carne
Brennan Carne
TWTony Walls
Tony Walls
AMAndrew McCombie
Andrew McCombie
LJLaura Joyce
Laura Joyce

7 May 2024 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
JPJohn W Pickering
John W Pickering
PKPeter Kavsak
Peter Kavsak
RCRobert H. Christenson
Robert H. Christenson
RTRichard W Troughton
Richard W Troughton
CPChristopher J Pemberton
Christopher J Pemberton
MTMartin P Than
Martin P Than
Background: Clinical decision-making for risk stratification for possible myocardial infarction (MI) uses high-sensitivity cardiac troponin (hs-cTn) thresholds that range from the limit of detection to several-fold higher than the upper reference limit (URL). To establish a minimum analytical variation standard, we can quantify the effect of variation on the population clinical measures of safety (sensitivity) and effectiveness [proportion below threshold, or positive predictive value (PPV)]. Methods: From large datasets of patients investigated for possible MI with the Abbott hs-cTnI and Roche hs-cTnT assays, we synthesized datasets of 1 000 000 simulated patients. Troponin concentrations were randomly varied several times based on absolute deviations of 0.5 to 3 ng/L and relative changes of 2% to 20% around the low-risk threshold (5 ng/L) and URLs, respectively. Results: For both assays at the low-risk thresholds, there were negligible differences in sensitivity (<0.3%) with increasing analytical variation. The proportion of patients characterized as low risk reduced by 30% to 29% (Roche) and 53% to 44% (Abbott). At the URL, increasing analytical variation also did not change sensitivity; the PPV fell by less than 3%. For risk stratification, increased delta thresholds (change between serial troponin concentrations) increased sensitivity at the cost of a decreased percentage of patients below the delta threshold, with the largest changes at the greatest analytical variation. Conclusions: At the low-risk threshold, analytical variation up to 3 ng/L minimally impacted the safety metric (sensitivity) but marginally reduced effectiveness. Similarly, at the URL even relative variation up to 25% minimally impacted safety metrics and effectiveness. Analytical variation for delta thresholds did not negatively impact sensitivity but decreased effectiveness.

13 June 2024 in BMJ Open
Verified
Journal Article
Open access
PDF file
JPJohn W Pickering
John W Pickering
GDGerard Devlin
Gerard Devlin
RBRichard Body
Richard Body
SASally Aldous
Sally Aldous
AJAllan S Jaffe
Allan S Jaffe
MTMartin Than
Martin Than
Introduction Clinical assessment in emergency departments (EDs) for possible acute myocardial infarction (AMI) requires at least one cardiac troponin (cTn) blood test. The turn-around time from blood draw to posting results in the clinical portal for central laboratory analysers is ~1–2 hours. New generation, high-sensitivity, point-of-care cardiac troponin I (POC-cTnI) assays use whole blood on a bedside (or near bedside) analyser that provides a rapid (8 min) result. This may expedite clinical decision-making and reduce length of stay. Our purpose is to determine if utilisation of a POC-cTnI testing reduces ED length of stay. We also aim to establish an optimised implementation process for the amended clinical pathway. Methods and analysis This quality improvement initiative has a pragmatic multihospital stepped-wedge cross-sectional cluster randomised design. Consecutive patients presenting to the ED with symptoms suggestive of possible AMI and having a cTn test will be included. Clusters (comprising one or two hospitals each) will change from their usual-care pathway to an amended pathway using POC-cTnI—the ‘intervention’. The dates of change will be randomised. Changes occur at 1 month intervals, with a minimum 2 month ‘run-in’ period. The intervention pathway will use a POC-cTnI measurement as an alternate to the laboratory-based cTn measurement. Clinical decision-making steps and logic will otherwise remain unchanged. The POC-cTnI is the Siemens (Erlangen Germany) Atellica VTLi high-sensitivity cTnI assay. The primary outcome is ED length of stay. The safety outcome is cardiac death or AMI within 30 days for patients discharged directly from the ED. Ethics and dissemination Ethics approval has been granted by the New Zealand Southern Health and Disability Ethics Committee, reference 21/STH/9. Results will be published in a peer-reviewed journal. Lay and academic presentations will be made. Māori-specific results will be disseminated to Māori stakeholders. Trial registration number ACTRN12619001189112.