Luis Carlos Estrada Petrocelli

Dr. Luis Carlos Estrada Petrocelli

Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology (BIST), Barcelona, Spain. Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Spain. Universidad Latina de Panamá, Facultad de Ingeniería, Panama, Panama
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Journal of Thoracic Disease
Verified
Journal Article
Open access
PDF file
JHJocelin Isabel Hall
Jocelin Isabel Hall
MLManuel Lozano
Manuel Lozano
Luis Carlos Estrada PetrocelliLuis Carlos Estrada Petrocelli
Luis Carlos Estrada Petrocelli
SBSurinder Birring
Surinder Birring
RTRichard Turner
Richard Turner
The widespread use of cough counting tools has, to date, been limited by a reliance on human input to determine cough frequency. However, over the last two decades advances in digital technology and audio capture have reduced this dependence. As a result, cough frequency is increasingly recognised as a measurable parameter of respiratory disease. Cough frequency is now the gold standard primary endpoint for trials of new treatments for chronic cough, has been investigated as a marker of infectiousness in tuberculosis (TB), and used to demonstrate recovery in exacerbations of chronic obstructive pulmonary disease (COPD). This review discusses the principles of automatic cough detection and summarises key currently and recently used cough counting technology in clinical research. It additionally makes some predictions on future directions in the field based on recent developments. It seems likely that newer approaches to signal processing, the adoption of techniques from automatic speech recognition, and the widespread ownership of mobile devices will help drive forward the development of real-time fully automated ambulatory cough frequency monitoring over the coming years. These changes should allow cough counting systems to transition from their current status as a niche research tool in chronic cough to a much more widely applicable method for assessing, investigating and understanding respiratory disease.

2 February 2015 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
Luis Carlos Estrada PetrocelliLuis Carlos Estrada Petrocelli
Luis Carlos Estrada Petrocelli
ATAbel Torres
Abel Torres
LULeonardo Uranga
Leonardo Uranga
Raimon JanéRaimon Jané
Raimon Jané
Diaphragm electromyography is a valuable technique for the recording of electrical activity of the diaphragm. The analysis of diaphragm electromyographic (EMGdi) signal amplitude is an alternative approach for the quantification of the neural respiratory drive (NRD). The EMGdi signal is, however, corrupted by electrocardiographic (ECG) activity, and this presence of cardiac activity can make the EMGdi interpretation more difficult. Traditionally, the EMGdi amplitude has been estimated using the average rectified value (ARV) and the root mean square (RMS). In this study, surface EMGdi signals were analyzed using the fixed sample entropy (fSampEn) algorithm, and compared to the traditional ARV and RMS methods. The fSampEn is calculated using a tolerance value fixed and independent of the standard deviation of the analysis window. Thus, this method quantifies the amplitude of the complex components of stochastic signals (such as EMGdi), and being less affected by changes in amplitude due to less complex components (such as ECG). The proposed method was tested in synthetic and recorded EMGdi signals. fSampEn was less sensitive to the effect of cardiac activity on EMGdi signals with different levels of NRD than ARV and RMS amplitude parameters. The mean and standard deviation of the Pearson's correlation values between inspiratory mouth pressure (an indirect measure of the respiratory muscle activity) and fSampEn, ARV, and RMS parameters, estimated in the recorded EMGdi signal at tidal volume (without inspiratory load), were 0.38 ± 0.12, 0.27 ± 0.11, and 0.11 ± 0.13, respectively. Whereas at 33 cmH 2 O (maximum inspiratory load) were 0.83 ± 0.02, 0.76 ± 0.07, and 0.61 ± 0.19, respectively. Our findings suggest that the proposed method may improve the evaluation of NRD.

1 September 2017 in Entropy
Verified
Journal Article
Open access
PDF file
Luis Carlos Estrada PetrocelliLuis Carlos Estrada Petrocelli
Luis Carlos Estrada Petrocelli
ATAbel Torres
Abel Torres
LULeonardo Uranga
Leonardo Uranga
Raimon JanéRaimon Jané
Raimon Jané
Fixed sample entropy (fSampEn) is a robust technique that allows the evaluation of inspiratory effort in diaphragm electromyography (EMGdi) signals, and has potential utility in sleep studies. To appropriately estimate respiratory effort, fSampEn requires the adjustment of several parameters. The aims of the present study were to evaluate the influence of the embedding dimension m, the tolerance value r, the size of the moving window, and the sampling frequency, and to establish recommendations for estimating the respiratory activity when using the fSampEn on surface EMGdi recorded for different inspiratory efforts. Values of m equal to 1 and r ranging from 0.1 to 0.64, and m equal to 2 and r ranging from 0.13 to 0.45, were found to be suitable for evaluating respiratory activity. fSampEn was less affected by window size than classical amplitude parameters. Finally, variations in sampling frequency could influence fSampEn results. In conclusion, the findings suggest the potential utility of fSampEn for estimating muscle respiratory effort in further sleep studies.

27 May 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DBDolores Blanco-Almazan
Dolores Blanco-Almazan
WGWillemijn Groenendaal
Willemijn Groenendaal
MLManuel Lozano-García
Manuel Lozano-García
Luis Carlos Estrada PetrocelliLuis Carlos Estrada Petrocelli
Luis Carlos Estrada Petrocelli
LLLien Lijnen
Lien Lijnen
Raimon JanéRaimon Jané
Raimon Jané
Chronic Obstructive Pulmonary Disease (COPD) is one of the most common chronic conditions. The current assessment of COPD requires a maximal maneuver during a spirometry test to quantify airflow limitations of patients. Other less invasive measurements such as thoracic bioimpedance and myographic signals have been studied as an alternative to classical methods as they provide information about respiration. Particularly, strong correlations have been shown between thoracic bioimpedance and respiratory volume. The main objective of this study is to investigate bioimpedance and its combination with myographic parameters in COPD patients to assess the applicability in respiratory disease monitoring. We measured bioimpedance, surface electromyography and surface mechanomyography in forty-three COPD patients during an incremental inspiratory threshold loading protocol. We introduced two novel features that can be used to assess COPD condition derived from the variation of bioimpedance and the electrical and mechanical activity during each respiratory cycle. These features demonstrate significant differences between mild and severe patients, indicating a lower inspiratory contribution of the inspiratory muscles to global respiratory ventilation in the severest COPD patients. In conclusion, the combination of bioimpedance and myographic signals provides useful indices to noninvasively assess the breathing of COPD patients.

22 February 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Luis Carlos Estrada PetrocelliLuis Carlos Estrada Petrocelli
Luis Carlos Estrada Petrocelli
ATAbel Torres
Abel Torres
LULeonardo Uranga
Leonardo Uranga
Raimon JanéRaimon Jané
Raimon Jané
This study evaluates the onset and offset of neural inspiratory time estimated from surface diaphragm electromyographic (EMGdi) recordings. EMGdi and airflow signals were recorded in ten healthy subjects according to two respiratory protocols based on respiratory rate (RR) increments, from 15 to 40 breaths per minute (bpm), and fractional inspiratory time (Ti/Ttot) decrements, from 0.54 to 0.18. The analysis of EMGdi signal amplitude is an alternative approach for the quantification of neural respiratory drive. The EMGdi amplitude was estimated using the fixed sample entropy computed over a 250 ms moving window of the EMGdi signal (EMGdifse). The neural onset was detected through a dynamic threshold over the EMGdifse using the kernel density estimation method, while neural offset was detected by finding when the EMGdifse had decreased to 70% of the peak value reached during inspiration. The Bland-Altman analysis between airflow and neural onsets showed a global bias of 46 ms in the RR protocol and 22 ms in the Ti /Ttot protocol. The Bland-Altman analysis between airflow and neural offsets reveals a global bias of 11 ms in the RR protocol and -2 ms in the Ti/T tot protocol. The relationship between pairs of RR values (Pearson's correlation coefficient of 0.99, Bland-=Altman limits of -2.39 to 2.41 bpm, and mean bias of 0.01 bpm) and between pairs of Ti/Ttot values (Pearson's correlation coefficient of 0.86, Bland-Altman limits of -0.11 to 0.10, and mean bias of -0.01) showed a good agreement. In conclusion, we propose a method for determining neural onset and neural offset based on noninvasive recordings of the electrical activity of the diaphragm that requires no filtering of cardiac muscle interference.

1 August 2015
Verified
Conference Paper
Closed access
Luis Carlos Estrada PetrocelliLuis Carlos Estrada Petrocelli
Luis Carlos Estrada Petrocelli
ATAbel Torres
Abel Torres
LULeonardo Uranga
Leonardo Uranga
Raimon JanéRaimon Jané
Raimon Jané
The scope of our work focuses on investigating the potential use of the built-in accelerometer of the smartphones for the recording of the respiratory activity and deriving the respiratory rate. Five healthy subjects performed an inspiratory load protocol. The excursion of the right chest was recorded using the built-in triaxial accelerometer of a smartphone along the x, y and z axes and with an external uniaxial accelerometer. Simultaneously, the respiratory airflow and the inspiratory mouth pressure were recorded, as reference respiratory signals. The chest acceleration signal recorded in the z axis with the smartphone was denoised using a scheme based on the ensemble empirical mode decomposition, a noise data assisted method which decomposes nonstationary and nonlinear signals into intrinsic mode functions. To distinguish noisy oscillatory modes from the relevant modes we use the detrended fluctuation analysis. We reported a very strong correlation between the acceleration of the z axis of the smartphone and the reference accelerometer across the inspiratory load protocol (from 0.80 to 0.97). Furthermore, the evaluation of the respiratory rate showed a very strong correlation (0.98). A good agreement was observed between the respiratory rate estimated with the chest acceleration signal from the z axis of the smartphone and with the respiratory airflow signal: Bland-Altman limits of agreement between -1.44 and 1.46 breaths per minute with a mean bias of -0.01 breaths per minute. This preliminary study provides a valuable insight into the use of the smartphone and its built-in accelerometer for respiratory monitoring.