Chenyang Liu

Prof. Chenyang Liu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2021 in IEEE Access
Verified
Journal Article
Open access
XCXu-Feng Cheng
Xu-Feng Cheng
Chenyang LiuChenyang Liu
Chenyang Liu
DWDianlong Wang
Dianlong Wang
YZYong Zhang
Yong Zhang
The soft-switching technology is widely used in DC-DC converters, DC-AC inverters, and AC-DC rectifiers. Soft-switching non-isolated DC/DC converters (Buck, Boost, and Buck-Boost) are the most active research area of the soft-switching technology, and fruitful results are achieved. However, there is currently no comprehensive review for the soft-switching technology of non-isolated DC/DC converters. This paper introduces soft-switching topologies for non-isolated DC/DC converters, and presents classification and characteristic of all kinds of soft-switching technologies. Some soft-switching technologies of derivative converters (non-inverting Buck-Boost converters and multiphase converters) are also presented. Finally future trends and generalized constitution methods of the soft-switching topology for non-isolated DC/DC converters are concluded. The soft-switching theory and constitution methods summarized in this article are expected to be able to guide the proposing of new soft-switching technologies for DC-DC converters.

18 August 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Chenyang LiuChenyang Liu
Chenyang Liu
KLKangning Li
Kangning Li
XZXiaoquan Zheng
Xiaoquan Zheng
MYMo Yin
Mo Yin
High-energy electrons in space can penetrate into dielectric materials on spacecraft and cause deep dielectric charging which is often harmful. The level of charging is determined not only by the incoming flux but also by the rates of electron accumulation and electron leaking. It is desirable to enable faster leaking of the accumulated charge. This paper discusses the nonlinear conductivities with space charge behavior of two samples of modified epoxy. They were obtained respectively by adding zinc oxide (ZnO) particles of two different sizes (2 μm, 10 μm) to pure epoxy (EP). We studied the conductivities of the samples and the space charge effects in strong electrical fields. Our results showed that the nonlinear conductivity threshold of 2 μm modified EP (ME2) was 1.7 × 107 V/m whereas that of 10 μm modified EP (ME10) was 1.4×107 V/m. These values are 50% and 40% higher than that of EP respectively. These results suggest that the modified epoxy materials (ME2 and ME10), if used on spacecraft, are better than pure EP for leaking away the accumulated charge, thus reducing the dielectric charging level. Meanwhile, space charge distribution tests indicated that 10 μm modified EP (ME10) had a nice charge dissipation performance, while 2 μm modified EP (ME2) did not have space charge accumulation. Finally we make the conclusion that nonlinear conductivity performance can affect space charge distribution for dielectric to a certain degree.

13 March 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
XCXu-Feng Cheng
Xu-Feng Cheng
Chenyang LiuChenyang Liu
Chenyang Liu
DWDianlong Wang
Dianlong Wang
YZYong Zhang
Yong Zhang
This brief presented a new soft-switching auxiliary circuit for the three-level buck converter with synchronous rectification (TLBC-SR). The new zero voltage switching (ZVS) auxiliary circuit only employs one inductor and one capacitor, and has the features as full soft-switching conditions, high efficiency, low output current ripples, and simple modulation control method. The detailed operation principle and soft-switching design method are also given. Finally, an experimental prototype is built to verify the proposed ZVS TLBC-SR. The experimental results show that all switches operate under zero voltage switching (ZVS) conditions, and the peak efficiency of the prototype is up to 96.85%@100kHz.

27 March 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
Chenyang LiuChenyang Liu
Chenyang Liu
XCXu-Feng Cheng
Xu-Feng Cheng
XZXiaoquan Zheng
Xiaoquan Zheng
High energy electrons would easily penetrate into spacecraft dielectrics (Epoxy) and accumulate inside, finally causing charge–discharge danger for spacecraft. Nonlinear conductivity modification of epoxy resin (EP) can automatically leak the accumulated charges and prevent charge–discharge from occurring. Inorganic fillers have a significant effect on the nonlinear conductivity characteristics of spacecraft dielectrics (Epoxy). This work reported the nonlinear conductivity modification influence on the space charge behavior of modified EP composite materials. The samples of modified ZnO/EP (MZ) and modified SiC/EP (MS) composite materials were prepared. The nonlinear conductivity experiment was carried out, and the results showed that: 1) the nonlinear electric-field thresholds of MZ and MS were 1.70 $\times$ 10 $^{7}$ and 1.54 $\times$ 10 $^{7}$ V/m, respectively; and 2) as the applied electric field rose from low level to high level, the average conductivity value of MZ increased from 3.24 $\times$ 10 $^{-13}$ to 6.27 $\times$ 10 $^{-12}$ S/m, and that of MS increased from 4.97 $\times$ 10 $^{-13}$ to 2.77 $\times$ 10 $^{-11}$ S/m. The space charge test results showed that: 1) the space charges inside MZ were positive, whereas they were negative inside MS and 2) as the applied electric field increased from 10 to 20 kV/mm, the peak value of space charge density of MZ decreased from 0.17 to 0.01 C/m $^{3}$ . The space charges inside MS could decrease closer to 0 rapidly under high electric field (20 kV/mm). Finally, the mechanism of inorganic fillers affecting the space charge distribution of modified EP was investigated, because the bandgap of SiC is narrower than that of ZnO, electrons can have a high-drift speed during transporting process; the transportation speed of electrons inside MZ was higher than that of holes, and ZnO addition led to the mass production of high trap densities and high energy levels inside MZ, so the space charge distribution of MZ was different with that of MS. The findings of this study confirmed that the modified EP composite materials (MZ and MS) both showed obvious nonlinear conductivity characteristics, and they were excellent potential materials for spacecraft to effectively leak away the accumulated space charges of dielectrics in space.

29 July 2021
Verified
Conference Paper
Closed access
BJBing Ji
Bing Ji
Xiaolei YangXiaolei Yang
Xiaolei Yang
Chenyang LiuChenyang Liu
Chenyang Liu
HXHaihang Xu
Haihang Xu
YJYuyang Ji
Yuyang Ji
STShuyi Tao
Shuyi Tao
The damage of the regulator winding is due to the carbon brush of the autotransformer which is unable to withstand too large current. The adjacent coil turns under the carbon brush contact will also cause short circuit due to long heating, which cannot guarantee the normal conduct of the test. According to the shortcomings of the above technology, a test device simulating live verification relay protection is designed. The device adopts a special microprocessing controller to control and calculate the collected data and information, and connect the Ethernet communication interface at the communication interface to improve the information management ability. The method can improve the verification function of simulated load measurement performance, and also meet the test requirements of the three - phase current conversion device directly on the bus current and the three phase voltage conversion device. Through a large number of field tests, the method has low error and high efficiency.

17 August 2023
Verified
Conference Paper
Closed access
XSXiaoyu Sun
Xiaoyu Sun
XLXun Li
Xun Li
KLKunpeng Liu
Kunpeng Liu
Chenyang LiuChenyang Liu
Chenyang Liu
A transmitting array design scheme for ground microwave wireless power transmission system is presented. To reduce the cost and simultaneously ensure a high transmission efficiency, a microstrip array based on subarrays technique is proposed. And the stepped amplitude distribution is adopted. The feeding network with the substrate integrated coaxial line technique is designed. With this structure, good isolation can be guaranteed. For the ground demonstration system associated the space solar power satellite, diameters of the transmitting and rectenna arrays are 1.6m and 7m, respectively. And they are separated by 100m. A high beam collection efficiency of 92.25% is achieved.