Luis Gabriel Gesteira

Prof. Luis Gabriel Gesteira

Department of Mechanical Engineering, Universidad de Zaragoza, Zaragoza, Aragon, Spain
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Luis Gabriel GesteiraLuis Gabriel Gesteira
Luis Gabriel Gesteira
JUJavier Uche
Javier Uche
Francesco Liberato CappielloFrancesco Liberato Cappiello
Francesco Liberato Cappiello
Luca CimminoLuca Cimmino
Luca Cimmino
This paper presents a thermoeconomic analysis of a polygeneration system based on solar-assisted desiccant cooling. The overall plant layout supplies electricity, space heating and cooling, domestic hot water, and freshwater for a residential building. The system combines photovoltaic/thermal collectors, photovoltaic panels, and a biomass boiler coupled with reverse osmosis and desiccant air conditioning. The plant was modeled in TRNSYS and simulated for 1 year. A parametric study defined the system’s setup. A thermoeconomic optimization determined the set of parameters that minimize the simple payback period. The optimal structure showed a total energy efficiency of 0.49 for the solar collectors and 0.16 for the solar panels. The coefficient of performance of the desiccant air conditioning was 0.37. Finally, a sensitivity analysis analyzed the influence of purchase electricity and natural gas costs and the electricity sell-back price on the system. The optimum simple payback was 20.68 years; however, the increase in the energy cost can reduce it by up to 85%.

15 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Luis Gabriel GesteiraLuis Gabriel Gesteira
Luis Gabriel Gesteira
JUJavier Uche
Javier Uche
This work aims to design and dynamically simulate a polygeneration system that integrates a solar-assisted desiccant cooling system for residential applications as an alternative to vapor compression systems. The overall plant layout supplies electricity, space heating and cooling, domestic hot water, and freshwater for a single-family townhouse located in the city of Almería in Spain. The leading technologies used in the system are photovoltaic/thermal collectors, reverse osmosis, and desiccant air conditioning. The system model was developed and accurately simulated in the TRNSYS environment for a 1-year simulation with a 5-min time step. Design optimization was carried out to investigate the system’s best configuration. The optimal structure showed a satisfactory total annual energy efficiency in solar collectors of about 0.35 and about 0.47 for desiccant air conditioning. Coverage of electricity, space heating and cooling, domestic hot water, and freshwater was 104.1%, 87.01%, 97.98%, 96.05 %, and 100 %, respectively. Furthermore, significant ratios for primary energy saving, 98.62%, and CO2 saving, 97.17%, were achieved. The users’ thermal comfort level was satisfactory over the entire year. Finally, a comparison with an alternative coastal site was performed to extend the polygeneration system’s applicability.

18 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JUJavier Uche
Javier Uche
Ignacio ZabalzaIgnacio Zabalza
Ignacio Zabalza
Luis Gabriel GesteiraLuis Gabriel Gesteira
Luis Gabriel Gesteira
AMAmaya Martínez-Gracia
Amaya Martínez-Gracia
SUSergio Uson
Sergio Uson
In line with the decarbonization of the domestic sector to meet the 2050 climate neutrality targets, this paper describes the energy, economic, and environmental analysis of a set of different novel configurations of polygeneration installations to provide electricity, air conditioning, domestic hot water, and desalinated water for a building of 80 dwellings. All arrangements were designed to cover 100% of the five demands required in the building with renewable energy only, from photovoltaic (PV) and photovoltaic-thermal (PVT) panels and biomass backup boilers (BB). Electricity can be sold to or purchased from the grid without electrical storage with batteries. Additional electricity generation with thermoelectric generators (TEG) coupled to the PVTs, and the BB was explicitly analyzed. The choice of electrically or thermally activated technologies (heat pump, HP/single-effect absorption chiller, SEAC for cooling and multi-effect distillation, MED/reverse osmosis, RO for desalination) created four configurations from the basic structure based on solar and biomass sources. Thus, the paper has studied four designs in detail and applied them to three case studies corresponding to different locations in Spain. They were modeled with TRNSYS and included specific models for desalination technologies. Both structures provide important energy and CO2 savings concerning the conventional supply of the building demands. The novel life-cycle analysis approach further increases the lifetime CO2 savings for all configurations as well. The electric option (the combination of HP and RO for cooling and desalting) was, by far, the most attractive solution in terms of liability and lower investment required in the three case studies.

1 June 2021 in Journal of Sustainable Development of Energy, Water and Environment Systems
Verified
Journal Article
Open access
PDF file
Luis Gabriel GesteiraLuis Gabriel Gesteira
Luis Gabriel Gesteira
JUJavier Uche
Javier Uche
LRLuanda K. de Oliveira Rodrigues
Luanda K. de Oliveira Rodrigues

27 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Luis Gabriel GesteiraLuis Gabriel Gesteira
Luis Gabriel Gesteira
JUJavier Uche
Javier Uche
NDNatalia Dejo-Oricain
Natalia Dejo-Oricain
This study presents an extension of a previous paper recently published by the authors. In particular, the current paper focuses on adding electrical storage to a polygeneration system developed for residential applications. Different from the previous work, it aims to design an off-grid facility. The polygeneration plant provides electricity, space heating and cooling, domestic hot water, and freshwater for a single-family dwelling in Almería, Spain. The main system technologies are photovoltaic/thermal collectors, reverse osmosis, and desiccant air conditioning. Lead-acid battery storage was added as a backup for the electrical system. The system was performed in the TRNSYS simulation environment for one year with a 5-min time step. A parametric study was carried out to investigate the grid dependence according to the number of batteries installed. Design optimization was also performed to provide the optimal system configuration for the off-grid case. A solar collector efficiency of 0.55 and a desiccant air-conditioning coefficient of performance of 0.42 were obtained. All demands were fully supplied, and the primary energy saving and CO2 saving achieved 100%. A minimum battery state of charge of 30% was reached for a few hours all year long.

1 May 2021 in International Journal of Smart Grid and Sustainable Energy Technologies
Verified
Journal Article
Open access
PDF file
RSRoberta P. S. Souza
Roberta P. S. Souza
Luis Gabriel GesteiraLuis Gabriel Gesteira
Luis Gabriel Gesteira
AAAntonio G. S. Almeida
Antonio G. S. Almeida
This paper presents a case study involving the design and energy saving analysis of an off-grid solar photovoltaic driven drinking fountain with battery storage. A dynamic simulation in TRNSYS software is performed to model and evaluate the transient processes occurring in this renewable system. A sensitivity analysis of the main design parameters, power generation capacity and electric storage capacity, was performed in order to optimize the scheme. The case study was carried out at Federal Institute of Education, Science and Technology of Bahia in Salvador, in the northeast of Brazil. The temperature profiles and electrical energy flows of the optimized system are investigated by means of a daily, weekly and yearly analysis. The outcomes achieved show that the optimized system showed a 33.3% increase in thermal efficiency and 15.1 % increase in the global efficiency in relation to the base case. This system was able to produce 5932.7 L of chilled water per year and a 65626.8 Wh reduction of primary energy consumption per year. This study can be applied to universities, schools or places with large flow of people.