Lydia Maigne

Dr. Lydia Maigne

University of Clermont Auvergne, Clermont-Ferrand, Auvergne-Rhône-Alpes, France
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2004 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SJS Jan
S Jan
GSGiovanni Santin
Giovanni Santin
DSD Strul
D Strul
SSS Staelens
S Staelens
KAK Assié
K Assié
CMC Morel
C Morel
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.

20 January 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SJS Jan
S Jan
DBD Benoit
D Benoit
EBE Becheva
E Becheva
TCT Carlier
T Carlier
FCF Cassol
F Cassol
IBIrene Buvat
Irene Buvat
GATE (Geant4 Application for Emission Tomography) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. Dedicated to the modelling of planar scintigraphy, single photon emission computed tomography (SPECT) and positron emission tomography (PET) acquisitions, this platform is widely used to assist PET and SPECT research. A recent extension of this platform, released by the OpenGATE collaboration as GATE V6, now also enables modelling of x-ray computed tomography and radiation therapy experiments. This paper presents an overview of the main additions and improvements implemented in GATE since the publication of the initial GATE paper (Jan et al 2004 Phys. Med. Biol. 49 4543-61). This includes new models available in GATE to simulate optical and hadronic processes, novelties in modelling tracer, organ or detector motion, new options for speeding up GATE simulations, examples illustrating the use of GATE V6 in radiotherapy applications and CT simulations, and preliminary results regarding the validation of GATE V6 for radiation therapy applications. Upon completion of extensive validation studies, GATE is expected to become a valuable tool for simulations involving both radiotherapy and imaging.

1 December 2015 in Physica Medica
Verified
Journal Article
Closed access
MBMario A Bernal
Mario A Bernal
MBM.C. Bordage
M.C. Bordage
JBJ.M.C. Brown
J.M.C. Brown
MDM. Davídková
M. Davídková
EDE. Delage
E. Delage
SISebastien Incerti
Sebastien Incerti

12 May 2014 in Medical Physics
Verified
Journal Article
Closed access
DSDavid Sarrut
David Sarrut
MBManuel Bardiès
Manuel Bardiès
NBNicolas Boussion
Nicolas Boussion
NFNicolas Freud
Nicolas Freud
SJSébastien Jan
Sébastien Jan
IBIrene Buvat
Irene Buvat

8 September 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DSDavid Sarrut
David Sarrut
NANicolas Arbor
Nicolas Arbor
TBThomas Baudier
Thomas Baudier
DBDamian Borys
Damian Borys
AEAne Etxebeste
Ane Etxebeste
LMLydia Maigne
Lydia Maigne
This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. Based on the shoulders of Geant4, the principal modules (geometry, physics, scorers) are described with brief descriptions of some key concepts (Volume, Actors, Digitizer). The main source code repositories are detailed together with the automated compilation and tests processes (Continuous Integration). We then described how the OpenGATE collaboration managed the collaborative development of about one hundred developers during almost 20 years. The impact of GATE on medical physics and cancer research is then summarized, and examples of a few key applications are given. Finally, future development perspectives are indicated.

5 January 2004 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DLD Lazaro
D Lazaro
IBIrene Buvat
Irene Buvat
GLG Loudos
G Loudos
DSD Strul
D Strul
GSGiovanni Santin
Giovanni Santin
VBV Breton
V Breton
Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.