2 August 2004 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MAManuel A Andrade
Manuel A Andrade
AMA.R. Messina
A.R. Messina
CRC.A. Rivera
C.A. Rivera
DOD. Olguin
D. Olguin
A systematic analytical procedure based on the concept of the analytic signal (AS) of Gabor is used to determine the time-varying attributes of torsional oscillations, namely the instantaneous amplitude and the instantaneous frequency. Methods for implementing the AS using the numeric Hilbert transform are given and criteria for characterizing nonlinear effects are discussed. The proposed methodology is demonstrated on the IEEE First Benchmark Model (FBM) for subsynchronous resonance studies. The AS analysis is performed on output data files generated by nonlinear simulations using the EMTP, but the method is general and is applicable to any nonlinear, nonstationary signal. Numerical results include the determination of the instantaneous frequency of torsional oscillation signals following large perturbations. Comparison of numerical results obtained by the proposed method with linear analysis techniques is provided.

1 January 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HEHector Esponda
Hector Esponda
Ernesto Vázquez-MartínezErnesto Vázquez-Martínez
Ernesto Vázquez-Martínez
MAManuel A Andrade
Manuel A Andrade
BJBrian Johnson
Brian Johnson
HEHector Esponda
Hector Esponda
This paper describes a differential algorithm for the protection of a three-phase transformer to differentiate transient phenomena, such as inrush currents and external faults from solid and turn-to-turn faults. This algorithm is based on the behavior of the second central moment (SCM) to identify the kind of event. Instantaneous differential currents are used as input signals to the algorithm once they are filtered and normalized. The algorithm compares the magnitude of the SCM with an established threshold based on the binomial distribution to achieve a successful identification of the event. If the magnitude of the SCM is above the limit, the algorithm identifies the event as a fault condition. Otherwise, the event is determined as a transient event or a steady-state condition. The threshold is setting-free if the transformer parameters are changed or if the harmonic content of the differential current varies. Also, the threshold does not have to be recalculated if the power system is modified. The D index was introduced to improve the fault-detection time when the current transformers experience saturation. This index uses the magnitude of the SCM as a basis and is compared with an established limit to detect the fault current. Both indices run in parallel, and if any of them does cross its respective threshold, a fault condition is determined. The algorithm is tested in a real-time digital simulator and is implemented in MATLAB. The algorithm was compared against the conventional differential protection with harmonic restraint to evaluate the performance of both indices in critical conditions. The results validate the performance of the algorithm and indicate that it can be the basis of a new algorithm to protect power transformers.

1 May 2022 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
FSFelix Rafael Segundo Sevilla
Felix Rafael Segundo Sevilla
YLYanli Liu
Yanli Liu
EBEmilio Barocio
Emilio Barocio
PKPetr Korba
Petr Korba
MAManuel A Andrade
Manuel A Andrade
JZJunbo Zhao
Junbo Zhao

25 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
MAMartha Acosta
Martha Acosta
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
Danijel TopićDanijel Topić
Danijel Topić
MAManuel A Andrade
Manuel A Andrade
The replacement of conventional generation sources by DER creates the need to carefully manage the reactive power maintaining the power system safe operation. The principal trend is to increase the DER volume connected to the distribution network in the coming years. Therefore, the microgrid represents an alternative to offer reactive power management due to excellent controllability features embedded in the DER, which enable effective interaction between the microgrid and the distribution network. This paper proposes a microgrid–iterative reactive power management approach of power-electronic converter based renewable technologies for day-ahead operation. It is designed to be a centralised control based on local measurements, which provides the optimal reactive power dispatch and minimise the total energy losses inside the microgrid and maintain the voltage profile within operational limits. The proposed optimal-centralised control is contrasted against seven local reactive power controls using a techno-economic approach considering the steady–state voltage profile, the energy losses, and the reactive power costs as performance metrics. Three different reactive power pricing are proposed. The numerical results demonstrate the optimal microgrid–interactive reactive power management is the most suitable techno-economic reactive power control for the day–ahead operation.

15 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
MAMartha Acosta
Martha Acosta
CAChoidorj Adiyabazar
Choidorj Adiyabazar
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
MAManuel A Andrade
Manuel A Andrade
Jose Luis Rueda TorresJose Luis Rueda Torres
Jose Luis Rueda Torres
JSJesús Manuel Riquelme Santos
Jesús Manuel Riquelme Santos
The Altai-Uliastai regional power system (AURPS) is a regional power system radially interconnected to the power system of Mongolia. The 110 kV interconnection is exceptionally long and susceptible to frequent trips because of weather conditions. The load-rich and low-inertia AURPS must be islanded during interconnection outages, and the under-frequency load shedding (UFLS) scheme must act to ensure secure operation. Traditional UFLS over-sheds local demand, negatively affecting the local population, especially during the cold Mongolian winter season. This research paper proposes a novel methodology to optimally calculate the settings of the UFLS scheme, where each parameter of the scheme is individually adjusted to minimise the total amount of disconnected load. This paper presents a computationally efficient methodology that is illustrated in a specially created co-simulation environment (DIgSILENT® PowerFactoryTM + Python). The results demonstrate an outstanding performance of the proposed approach when compared with the traditional one.

1 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
MAMartha Acosta
Martha Acosta
DPDaniel Pettersen
Daniel Pettersen
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
JPJaime Peredo
Jaime Peredo
MAManuel A Andrade
Manuel A Andrade
The integration of renewable resources is quickly growing in the Nordic power system (NPS), and it has led to increasing challenges for the operation and control of the NPS. Nordic countries require that the first-generation power plants have a more flexible operation regime to overcomes power imbalances coming from fluctuations of the demand and supply. This paper assesses optimal frequency support of variable-speed hydropower plants installed in Telemark and Vestfold, Norway, considering future scenarios of NPS. The total kinetic energy of the NPS is expected to be significantly reduced in the future. This paper looks into the implementation of hydropower units with a variable-speed operation regime and battery energy storage systems (BESS), equipped with fast-active power controller (FAPC) technology, to provide fast frequency response after a system frequency disturbance. The frequency support was formulated as an optimization process; therefore, the parameter of the FAPC was optimally calculated for future scenarios of low inertia in NPS. Three main futures scenarios were developed for technology penetration in the Vestfold and Telemark area in Norway. The simulation results showed that the integration variable-speed hydropower units and BESS technologies improved the frequency response even in low-kinetic energy scenarios.