Hanxu MA

Dr. Hanxu MA

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2026 in Photonics Research
Verified
Journal Article
Closed access
HMHanxu MA
Hanxu MA
SQShunda Qiao
Shunda Qiao
YHYing He
Ying He
CZChu Zhang
Chu Zhang
Yufei MaYufei Ma
Yufei Ma
In this paper, a novel light-induced thermoelastic spectroscopy (LITES) sensor based on overtone acoustic feedback enhancement (OAFE) is proposed for the first time to improve the sensing performance. A self-designed low-frequency quartz tuning fork (QTF) is employed as the sensing element. Using dual-frequency modulation, the QTF’s first overtone signal is amplified to drive an electroacoustic transducer (EAT), generating a fundamental acoustic signal. This creates an acoustic feedback loop that significantly enhances the QTF’s fundamental vibration. Methane ( CH 4 ), a highly flammable and explosive gas, is selected as the target gas in this study. Experimental results show that compared to the traditional LITES sensor, the signal-to-noise ratio (SNR) of the OAFE-based LITES sensor is improved by a factor of 6.19. The reported OAFE-based LITES sensor exhibits an excellent linear response characteristic to CH 4 concentration, with a minimum detection limit (MDL) of 1.08 ppm. Additionally, through Allan deviation analysis, when the integration time reaches 70 s, the MDL of the OAFE-based LITES sensor can be optimized to 0.29 ppm.

22 May 2026 in Optics Letters
Verified
Journal Article
Closed access
SQShunda Qiao
Shunda Qiao
ZLZiheng Lv
Ziheng Lv
HMHanxu MA
Hanxu MA
BLBangyu Liu
Bangyu Liu
CSChenzhao Sang
Chenzhao Sang
Yufei MaYufei Ma
Yufei Ma
In this work, a novel “1”-shaped acoustic cascaded resonator enhanced light-induced thermoelastic spectroscopy (LITES) gas sensing system is proposed for the first time, to the best of our knowledge. The designed resonator consists of three one-dimensional acoustic tubes, enabling cascaded amplification and efficient accumulation of acoustic energy in the LITES system. Finite element analysis (FEA) was employed to investigate the acoustic field distribution and optimize the key geometric parameters. Acetylene (C 2 H 2 ) was selected as the target gas for validation. Compared with a conventional bare quartz tuning fork (QTF)-based LITES system, the proposed configuration achieved a 14.05-fold enhancement in the signal amplitude, and a minimum detection limit (MDL) of 3.1 ppm was obtained. Furthermore, the MDL was improved to 405 ppb at an average time of 200 s using Allan deviation analysis. The results demonstrate that the proposed multi-stage acoustic resonance strategy significantly enhances LITES performance and shows great potential for trace gas detection.

24 February 2025 in Optics Express
Verified
Journal Article
Closed access
HMHanxu MA
Hanxu MA
SQShunda Qiao
Shunda Qiao
YHYing He
Ying He
CZChu Zhang
Chu Zhang
Yufei MaYufei Ma
Yufei Ma
What we believe to be a novel load capacitance matching method is proposed for adjusting the resonant frequency of a quartz tuning fork (QTF) in a multi-QTF-based laser spectroscopy gas sensor for the first time. A sensing system integrating quartz-enhanced photoacoustic spectroscopy (QEPAS) and light-induced thermoelastic spectroscopy (LITES) was constructed to validate the proposed method. In this system, the QEPAS module consists of QTF1, while the LITES module is based on QTF2. Methane was chosen as the target gas to evaluate both the reliability of the method and the sensor's performance. Without frequency matching, the difference in resonant frequencies between QTF1 and QTF2 was 6.67 Hz, resulting in a superposition efficiency of only 33.7% for the QEPAS-LITES sensor. When the load capacitance matching method was applied, the load capacitance of QTF2 was adjusted to bring its resonant frequency closer to that of QTF1. This successfully matched the resonant frequencies of both QTFs, improving the superposition efficiency to 98.7%. The QEPAS-LITES sensor utilizing the load capacitance matching method demonstrated a strong linear concentration response. Additionally, long-term stability was evaluated through Allan deviation analysis. With an average time of 100 s, the minimum detection limit of the QEPAS-LITES sensor system was improved to 5.91 ppm.

1 June 2026 in Reports on Progress in Physics
Verified
Journal Article
Closed access
HMHanxu MA
Hanxu MA
Shunda QiaoShunda Qiao
Shunda Qiao
YHYing He
Ying He
HSHaiyue Sun
Haiyue Sun
Yufei MaYufei Ma
Yufei Ma
This paper proposed an optical detection mechanism that utilized orthogonal phase modulation (OPM) and Lissajous mode decoupling within a light-induced thermoelastic spectroscopy (LITES) sensor for the first time, enabling real-time multi-component gas sensing. By establishing a two-dimensional forced vibration model of a quartz tuning fork (QTF) under dual-path OPM, it revealed the vibration mode coupling mechanism induced by non-ideal phase and amplitude conditions, thereby providing a theoretical basis and optimization pathway for suppressing channel crosstalk. In the OPM-LITES sensor, two continuous-wave distributed feedback lasers were modulated by sinusoidal waves with the same frequency ( f 0 /2, where f 0 is the resonant frequency of the QTF) but a phase difference of 45°. The combined beam, after wavelength division multiplexing, co-excited the self-designed low-frequency QTF. The piezoelectric signal generated by the QTF underwent orthogonal demodulation via a lock-in amplifier (LIA). The concentration information for the two gases was independently retrieved from the decoupled X -component and Y -component of the LIA. Experimental results demonstrated that the OPM-LITES sensor exhibited excellent linear responses to both methane (CH 4 ) and acetylene (C 2 H 2 ), with average relative systematic errors of 0.54% and 0.79%, and maximum relative errors of 1.72% and 1.38%, respectively. Allan deviation analysis indicated that the minimum detection limits (MDLs) for CH 4 and C 2 H 2 reached 0.32 ppm and 0.29 ppm, with normalized noise-equivalent absorption coefficients of 5.09 × 10 −9 cm −1 ·W·Hz −1/2 and 6.18 × 10 −9 cm −1 ·W·Hz −1/2 , respectively. This study not only provided a simple and efficient solution for real-time multi-component gas detection but also established a novel theoretical framework for mode decoupling and signal processing in spectroscopic sensing.

18 December 2025 in Laser & Photonics Reviews
Verified
Journal Article
Closed access
HMHanxu MA
Hanxu MA
CLChuanning Li
Chuanning Li
YHYing He
Ying He
SQShunda Qiao
Shunda Qiao
CZChu Zhang
Chu Zhang
Yufei MaYufei Ma
Yufei Ma

6 April 2026 in Laser & Photonics Reviews
Verified
Journal Article
Closed access
HMHanxu MA
Hanxu MA
BLBotao Liu
Botao Liu
SQShunda Qiao
Shunda Qiao
YHYing He
Ying He
HSHaiyue Sun
Haiyue Sun
Yufei MaYufei Ma
Yufei Ma