Mahdi Saadatmand

Dr. Mahdi Saadatmand

Power System Secure Operation Research Center, Amirkabir University of Technology, Tehran, Tehrān, Iran
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2021 in IEEE Access
Verified
Journal Article
Open access
Mahdi SaadatmandMahdi Saadatmand
Mahdi Saadatmand
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
Ali MoghassemiAli Moghassemi
Ali Moghassemi
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
PSPierluigi Siano
Pierluigi Siano
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
Global warming and the desire to increase the use of clean energy have led to increasing the installation and operation of renewable energy power plants (REPPs), especially large-scale photovoltaic (PV) farms (LPFs). Given that the LPFs are added to power system or replace conventional power plants, they must be able to perform the basic tasks of synchronous generators (SGs). One of these tasks is the ability to mitigate the low-frequency oscillation (LFO) risk. Also, one of the LPFs problems is reducing the power system inertia and increasing the risk of LFOs. Therefore, these types of power plants must damp the LFOs through a power oscillation damping controller (PODC), similar to the performance of power system stabilizers (PSSs) in the SGs. This paper represents an overview of the different PODCs and control methods for LFOs damping by LPF. It seems that it can be a driver for future studies. Different studies show that the application of PODCs for LPFs can play an effective role to damp the LFOs and increase the power system stability.

2 July 2021 in IEEE Access
Verified
Journal Article
Open access
Mahdi SaadatmandMahdi Saadatmand
Mahdi Saadatmand
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
PSPierluigi Siano
Pierluigi Siano
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
Due to global warming problems and increasing environmental pollution, there is a strong tendency to install and apply renewable energy power plants (REPPs) around the world. On the other hand, with the increasing development of information and communication technology (ICT) infrastructures, power systems are using these infrastructures to act as smart grids. In fact, future modern power systems should be considered as smart grids with many small and large scale REPPs. One of the main problems and challenges of the REPPs is uncertainty and fluctuation of electrical power generation. Accordingly, a suitable solution can be combination of different types of REPPs. So, the penetration rate of large-scale wind-PV farms (LWPF) is expected to increase sharply in the coming years. Given that the LWPFs are added to the grid or will replace fossil fuel power plants, they should be able to play the important roles of synchronous generators such as power low-frequency oscillation (LFO) damping. In this paper, an LFO damping system is suggested for a LWPF, based on a phasor measurement unit (PMU)-based fractional-order proportional–integral–derivative (FOPID) controller with wide range of stability area and proper robustness to many power system uncertainties. Finally, the performance of the proposed method is evaluated under different operating conditions in a benchmark smart system.

21 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
Mahdi SaadatmandMahdi Saadatmand
Mahdi Saadatmand
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
Innocent KamwaInnocent Kamwa
Innocent Kamwa
PSPierluigi Siano
Pierluigi Siano
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
In recent decades, various types of control techniques have been proposed for use in power systems. Among them, the use of a proportional–integral–derivative (PID) controller is widely recognized as an effective technique. The generalized type of this controller is the fractional-order PID (FOPID) controller. This type of controller provides a wider range of stability area due to the fractional orders of integrals and derivatives. These types of controllers have been significantly considered as a new approach in power engineering that can enhance the operation and stability of power systems. This paper represents a comprehensive overview of the FOPID controller and its applications in modern power systems for enhancing low-frequency oscillation (LFO) damping. In addition, the performance of this type of controller has been evaluated in a benchmark test system. It can be a driver for the development of FOPID controller applications in modern power systems. Investigation of different pieces of research shows that FOPID controllers, as robust controllers, can play an efficient role in modern power systems.

10 January 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
Mahdi SaadatmandMahdi Saadatmand
Mahdi Saadatmand
BMBabak Mozafari
Babak Mozafari
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
SSSoodabeh Soleymani
Soodabeh Soleymani
In recent years, the installation of large‐scale photovoltaic (PV) farms (LPFs) is expanding around the world. Due to the addition of LPFs to the power system and increasing their penetration level, they should be able to undertake the most common tasks of conventional power plants in coordinated with other devices in the power system. Damping of low‐frequency oscillation (LFO) through the power system stabilizers (PSSs) is regarded as one of these common tasks. Therefore, the LPF must be able to damp the LFO in coordinated with the PSSs. This paper proposes a new method for LFO damping in power system which is based on optimal coordination of wide‐area measurement‐based fractional‐order proportional‐integral‐derivative (WMFOPID) controller as an auxiliary controller for LPF and PSSs of synchronous generators. The performance evaluation of the optimal coordinated WMFOPID controller is performed in a smart two‐area power system and is compared with other controllers in terms of LFO damping. The simulation results show the better performance of the optimal coordinated WMFOPID controller compared to the uncoordinated case and determine the effectiveness of the novel proposed method for LFO damping. The results also show the high robustness of the optimal WMFOPID controller compared to previous controllers, against some uncertainties in the power system.

1 June 2020 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
Mahdi SaadatmandMahdi Saadatmand
Mahdi Saadatmand
BMBabak Mozafari
Babak Mozafari
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
SSSoodabeh Soleymani
Soodabeh Soleymani
The penetration of large-scale photovoltaic farms (LPFs) is ever increasing. Given that LPFs are added to power systems or replaced by conventional power plants, they should undertake the most common tasks of synchronous generators. One of these tasks is the low-frequency oscillation (LFO) damping using power system stabilizer. This paper proposes a general method for LFO damping using LPFs by designing an optimal proportional-integral-derivative (PID) controller as a power oscillation damper in the nonlinear control loop of LPF. Considering the need for a valid LPF model, therefore the second generation generic model, developed and approved by western electricity coordinating council, is used. The PID controller is optimally tuned using the particle swarm optimization algorithm in order to produce an effective LFO damping. Finally, the performance of this controller is investigated in the modified two-area test system, showing the proper performance of the LPF for LFO damping using the proposed optimal PID controller in the various operating condition and different short circuit ratio values.

27 January 2020 in Turkish Journal of Electrical Engineering and Computer Sciences
Verified
Journal Article
Closed access
Mahdi SaadatmandMahdi Saadatmand
Mahdi Saadatmand
BMBabak Mozafari
Babak Mozafari
Gevork B. GharehpetianGevork B. Gharehpetian
Gevork B. Gharehpetian
SSSoodabeh Soleymani
Soodabeh Soleymani
The penetration of inverter-based power plants (IBPPs), such as large-scale photovoltaic (PV) power plants (LPPPs), is ever increasing considering the merits of renewable energy power plants (REPPs). Given that IBPPs are added to power systems or replaced by conventional power plants, they should undertake the most common tasks of synchronous generators. The low-frequency oscillation (LFO) damping through the power system stabilizers (PSSs) of synchronous generators is regarded as one of the common tasks in power plants. This paper proposes an optimal fractional-order proportional-integral-derivative (FOPID) controller implemented in the control loop of IBPPs for LFO damping in power systems. For this purpose, the last version of the generic dynamic model for renewable technologies (GDMRT) is used, which was released by the Western Electricity Coordinating Council (WECC) and Electric Power Research Institute (EPRI). In addition, an LPPP is studied as a case study. The FOPID controller is optimally tuned using the particle swarm optimization (PSO) algorithm in order to produce effective LFO damping. Finally, the performance of this controller is simulated and investigated in a two-area test system, showing the better performance of the LPPP for LFO damping by using the proposed optimal FOPID controller compared to the optimal lead-lag controller and optimal PID controller