Malik Ismail Alamayreh

Dr. Malik Ismail Alamayreh

Assistant Professor
orcid
Assosiate Professor in Thermal-Fluids

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ali AlahmerAli Alahmer
Ali Alahmer
Malik Ismail AlamayrehMalik Ismail Alamayreh
Malik Ismail Alamayreh
Ahmad MostafaAhmad Mostafa
Ahmad Mostafa
MAMohammad Al-Dabbas
Mohammad Al-Dabbas
Hegazy RezkHegazy Rezk
Hegazy Rezk
Magnetic refrigeration is a fascinating superior choice technology as compared with traditional refrigeration that relies on a unique property of particular materials, known as the magnetocaloric effect (MCE). This paper provides a thorough understanding of different magnetic refrigeration technologies using a variety of models to evaluate the coefficient of performance (COP) and specific cooling capacity outputs. Accordingly, magnetic refrigeration models are divided into four categories: rotating, reciprocating, C-shaped magnetic refrigeration, and active magnetic regenerator. The working principles of these models were described, and their outputs were extracted and compared. Furthermore, the influence of the magnetocaloric effect, the magnetization area, and the thermodynamic processes and cycles on the efficiency of magnetic refrigeration was investigated and discussed to achieve a maximum cooling capacity. The classes of magnetocaloric magnetic materials were summarized from previous studies and their potential magnetic characteristics are emphasized. The essential characteristics of magnetic refrigeration systems are highlighted to determine the significant advantages, difficulties, drawbacks, and feasibility analyses of these systems. Moreover, a cost analysis was provided in order to judge the feasibility of these systems for commercial use.

23 February 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
HAHussein Alahmer
Hussein Alahmer
Ali AlahmerAli Alahmer
Ali Alahmer
Malik Ismail AlamayrehMalik Ismail Alamayreh
Malik Ismail Alamayreh
Mohammad AlrbaiMohammad Alrbai
Mohammad Alrbai
Raed Al-RbaihatRaed Al-Rbaihat
Raed Al-Rbaihat
RARazan J Ahmad Alkhazaleh
Razan J Ahmad Alkhazaleh
Water-in-diesel (W/D) emulsion fuel is a potentially viable diesel fuel that can simultaneously enhance engine performance and reduce exhaust emissions in a current diesel engine without requiring engine modifications or incurring additional costs. In a consistent manner, the current study examines the impact of adding water, in the range of 5–30% wt. (5% increment) and 2% surfactant of polysorbate 20, on the performance in terms of brake torque (BT) and exhaust emissions of a four-cylinder four-stroke diesel engine. The relationship between independent factors, including water addition and engine speed, and dependent factors, including different exhaust released emissions and BT, was initially generated using machine learning support vector regression (SVR). Subsequently, a robust and modern optimization of the sea-horse optimizer (SHO) was run through the SVR model to find the optimal water addition and engine speed for improving the BT and lowering exhaust emissions. Furthermore, the SVR model was compared to the artificial neural network (ANN) model in terms of R-squared and mean square error (MSE). According to the experimental results, the BT was boosted by 3.34% compared to pure diesel at 5% water addition. The highest reduction in carbon monoxide (CO) and unburned hydrocarbon (UHC) was 9.57% and 15.63%, respectively, at 15% of water addition compared to diesel fuel. The nitrogen oxides (NOx) emissions from emulsified fuel were significantly lower than those from pure diesel, with a maximum decrease of 67.14% at 30% water addition. The suggested SVR-SHO model demonstrated superior prediction reliability, with a significant R-Squared of more than 0.98 and a low MSE of less than 0.003. The SHO revealed that adding 15% water to the W/D emulsion fuel at an engine speed of 1848 rpm yielded the optimum BT, CO, UHC, and NOx values of 49.5 N.m, 0.5%, 57 ppm, and 369 ppm, respectively. Finally, these outcomes have important implications for the potential of the SVR-SHO approach to minimize engine exhaust emissions while maximizing engine performance.

31 January 2023 in Fuels
Verified
Journal Article
Open access
PDF file
HAHussein Alahmer
Hussein Alahmer
Ali AlahmerAli Alahmer
Ali Alahmer
RARazan J Ahmad Alkhazaleh
Razan J Ahmad Alkhazaleh
Mohammad AlrbaiMohammad Alrbai
Mohammad Alrbai
Malik Ismail AlamayrehMalik Ismail Alamayreh
Malik Ismail Alamayreh
Water-in-diesel (W/D) emulsion fuel is a potential alternative fuel that can simultaneously lower NOx exhaust emissions and improves combustion efficiency. Additionally, there are no additional costs or engine modifications required when using W/D emulsion fuel. The proportion of water added and engine speed is crucial factors influencing engine behavior. This study aims to examine the impact of the W/D emulsion diesel fuel on engine performance and NOx pollutant emissions using a compression ignition (CI) engine. The emulsion fuel had water content ranging from 0 to 30% with a 5% increment, and 2% surfactant was employed. The tests were performed at speeds ranging from 1000 to 3000 rpm. All W/D emulsion fuel was compared to a standard of pure diesel in all tests. A four-cylinder, four-stroke, water-cooled, direct-injection diesel engine test bed was used for the experiments. The performance and exhaust emissions of the diesel engine were measured at full load and various engine speeds using a dynamometer and an exhaust gas analyzer, respectively. The second purpose of this study is to illustrate the application of two optimizers, grey wolf optimizer (GWO) and intelligent grey wolf optimizer (IGOW), along with using multivariate polynomial regression (MPR) to identify the optimum (W/D) emulsion blend percentage and engine speed to enhance the performance, reduce fuel consumption, and reduce NOX exhaust emissions of a diesel engine operating. The engine speed and proportion of water in the fuel mixture were the independent variables (inputs), while brake power (BP), brake thermal efficiency (BTE), brake-specific fuel consumption (BSFC), and NOx were the dependent variables (outcomes). It was experimentally observed that utilizing emulsified gasoline generally enhances engine performance and decreases emissions in general. Experimentally, at 5% water content and 2000 rpm, the BSFC has a minimal value of 0.258 kJ/kW·h. Under the same conditions, the maximum BP of 11.6 kW and BTE of 32.8% were achieved. According to the IGWO process findings, adding 9% water to diesel fuel and running the engine at a speed of 1998 rpm produced the highest BP (11.2 kW) and BTE (33.3%) and the lowest BSFC (0.259 kg/kW·h) and reduced NOx by 14.3% compared with the CI engine powered by pure diesel. The accuracy of the model is high, as indicated by a correlation coefficient R2 exceeding 0.97 and a mean absolute error (MAE) less than 0.04. In terms of the optimizer, the IGWO performs better than GWO in determining the optimal water addition and engine speed. This is attributed to the IGWO has excellent exploratory capability in the early stages of searching.


18 June 2012 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
Malik Ismail AlamayrehMalik Ismail Alamayreh
Malik Ismail Alamayreh
HHHarald Hofmann
Harald Hofmann
ONOve Nilsson
Ove Nilsson
CWChristian Weindl
Christian Weindl
ADAntonio R. Delgado
Antonio R. Delgado
This paper aims at understanding the design concept and behavior of the ionized gases inside a new electrical contactor. The switching device is designed for ac and dc operations up to 3.5 kV and nominal currents up to 800 A. The contactor consists of five electrodes: two anodes, two cathodes, and a moving electrode or bridge which works as an anode and a cathode simultaneously. In order to increase the safety, the electrical contactor includes two contact points. The line current can be diverted into an arc between the electrode and the bridge and an arc between the runner electrodes. The movement of the ionized gases is controlled by two permanent magnets and two coils installed near the electrodes. The arc plasma itself feeds the coils with current. The arc plasma velocity increases if more current is allocated in the arc plasma. The dynamics of ionized gases in the contactor is analyzed using two optical methods, viz., optical imaging method and high-speed camera (HSC). The optical imaging software has been developed to generate dynamic images of the high-speed ionized gases at a rate of 50 000 frames/s. The results of this method have been compared with those obtained using an HSC. A transient numerical model has been developed to simulate the arc plasma inside the main runner for the case of dc current. The properties of the air plasma are considered variable with temperature and pressure. The calculation shows the position and temperature of the arc plasma as a function of time.

3 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
Malik Ismail AlamayrehMalik Ismail Alamayreh
Malik Ismail Alamayreh
Ali AlahmerAli Alahmer
Ali Alahmer
MYmai bani younes
mai bani younes
SBSubhi Bazlamit
Subhi Bazlamit
Several techniques for cooling mass concrete structures were developed in order to increase structural integrity and reduce the influence of cement hydration, which sometimes causes cracking in concrete structures, negatively affecting their durability. This research focuses on cooling system design, initial investment, and the influence of different refrigerants on cooling system performance aims in producing higher quality massive concrete. Cooling aggregates in massive concrete structures such as desert dams can be performed by employing cooled air from an air conditioning duct system or chilled water. The experimental study illustrates the relationship between the coefficient of performance COP, the evaporator temperature, cooling capacity, and refrigerant mass flow rate as a function of the evaporator temperature, cooling capacity, and refrigerant mass flow rate. The findings of the experiments were utilized to verify a numerical model developed utilizing engineering equation solver (EES) software. The performance of the vapor compression of the cooling systems was compared using alternative refrigerants, including R22, R32, and R410a at different operating conditions. This study revealed that R22 refrigerant has a higher coefficient of performance than R32 and R410A, while R32 has the highest cooling capacity among other refrigerants.