The design of ground source heat pumps is a fundamental step to ensure the high energy efficiency of heat pump systems throughout their operating years. To enhance the diffusion of ground source heat pump systems, two different tools are developed in the H2020 research project named, “Cheap GSHPs”: A design tool and a decision support system. In both cases, the energy demand of the buildings may not be calculated by the user. The main input data, to evaluate the size of the borehole heat exchangers, is the building energy demand. This paper presents a methodology to correlate energy demand, building typologies, and climatic conditions for different types of residential buildings. Rather than envelope properties, three insulation levels have been considered in different climatic conditions to set up a database of energy profiles. Analyzing European climatic test reference years, 23 locations have been considered. For each location, the overall energy and the mean hourly monthly energy profiles for heating and cooling have been calculated. Pre-calculated profiles are needed to size generation systems and, in particular, ground source heat pumps. For this reason, correlations based on the degree days for heating and cooling demand have been found in order to generalize the results for different buildings. These correlations depend on the Köppen–Geiger climate scale.
Geothermal heat is an increasingly adopted source for satisfying all thermal purposes in buildings by reversible heat pumps (HP). However, for residential buildings located in moderate climates, geocooling, that implies the use of geothermal source for cooling buildings without the operation of HP, is an efficient alternative for space cooling not yet explored enough. Geocooling allows two main benefits: to cool the buildings by high energy efficiencies improving summer comfort; to recharge the ground if space heating is provided by HP exploiting the geothermal source (GSHP). In these cases, geocooling allows to avoid the decreasing of the performances of the GSHP for space heating over the years. To explore these issues, a method has been developed and tested on a real case: a new residential building in Lugano (southern Switzerland) coupled with 13 borehole heat exchangers. The system provides space heating in winter by a GSHP and space cooling in summer by geocooling. During a 40 months monitoring campaign, data such as temperatures, heat flows and electricity consumptions were recorded to calibrate the model and verify the benefits of such configuration. Focusing on summer operation, the efficiency of the system, after the improvements implemented, is above 30, confirming, at least in similar contexts, the feasibility of geocooling. Achieved results provides knowledge for future installations, underlining the replication potential and the possible limits.
The manuscript analyses the management of low and ultra-low-temperature district heating systems (DHS) coupled with centralised and decentralised heat pumps. Operative conditions are defined in order to satisfy the heating needs without overloading the electric grid. The results are achieved by dynamic simulations, based on a real DHS located in southern Switzerland. At the building level, the heating needs are estimated considering real data and simultaneous energy simulations. Two DHS configurations, alternatives to the existing one, are simulated and suitable parameters for the management of the DHS are selected. The global performance of the two DHS is evaluated by KPIs also including the flexibility and the impact on the electric peak due to heat pumps. The achieved results are discussed providing suggestions for the stakeholders involved in DHS management for an optimal matching of the electric grid and thermal networks towards a reduction of the peak power. The rule-based control strategies defined allow the expected electric peak shaving and load levelling, conversely, the yearly energy consumptions are lightly increased and have to be further investigated. The outcomes demonstrate a global better performance of the ultra-low temperature DHS in terms of response to the applied control strategies and of energy savings.