Michele De Carli

Dr. Michele De Carli

Department of Industrial Engineering, University of Padova, Via Venezia 1, 35131 Padova, Italy

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
DMDavide Menegazzo
Davide Menegazzo
GLGiulia Lombardo
Giulia Lombardo
sergio Bobbosergio Bobbo
sergio Bobbo
MCMichele De Carli
Michele De Carli
LFLaura Fedele
Laura Fedele
In the European Union, 40% of the overall final energy consumption is attributable to the buildings sector. A reason for such data may be found considering that the great majority of the building stock is more than 40 years old. According to the European Commission, an interesting potential lies in the refurbishment of the building sector, and heat pump technology has been recognized as one of the most cost-effective solutions to tackle the environmental issue of this sector. Regarding heat pump technology, ground-source heat pumps (GSHPs) have been proven to be the most efficient solution on equal boundary conditions. Despite this, in most EU states’ markets, GSHPs hold only a small market share with respect to air-source heat pumps. In this paper, the state of art and possible future developments of GSHP technology have been reviewed together with a focus on the potential of such technology, most of all on the refurbishment of existing buildings, and on the obstacles to its spread. The state of art of borehole heat exchangers has been studied, focusing on the parameters characterizing the outside pipe and the pipe itself, i.e., pipe and grout materials. Moreover, an overview on the last developments involving refrigerants and secondary fluids is given. Finally, the design and control strategies of GSHPs have been reviewed.

13 June 2017 in Energies
Verified
Journal Article
Open access
PDF file
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
GEGiuseppe Emmi
Giuseppe Emmi
SGSamantha Graci
Samantha Graci
MCMichele De Carli
Michele De Carli
MCMatteo Cultrera
Matteo Cultrera
Adriana BernardiAdriana Bernardi
Adriana Bernardi
The design phase of ground source heat pump systems is an extremely important one as many of the decisions made at that time can affect the system’s energy performance as well as installation and operating costs. The current study examined the interpretation of thermal response testing measurements used to evaluate the equivalent ground thermal conductivity and thus to design the system. All the measurements were taken at the same geological site located in Molinella, Bologna (Italy) where a variety of borehole heat exchangers (BHEs) had been installed and investigated within the project Cheap-GSHPs (Cheap and efficient application of reliable Ground Source Heat exchangers and Pumps) of the European Union’s Horizon 2020 research and innovation program. The measurements were initially analyzed in accordance with the common interpretation based on the first-order approximation of the solution for the infinite line source model and then by utilizing the complete solutions of both the infinite line and cylinder source models. An inverse numerical approach based on a detailed model that considers the current geometry of the BHE and the axial heat transfer as well as the effect of weather on the ground surface was also used. Study findings revealed that the best result was generally obtained using the inverse numerical interpretation.

29 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
JVJacopo Vivian
Jacopo Vivian
MCMattia Chinello
Mattia Chinello
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
MCMichele De Carli
Michele De Carli
Renewable Energy Communities have been recently introduced in European legislation to promote distributed generation from renewable energy sources. In fact, they allow to produce and consume energy from shared local power plants. Low temperature district heating and cooling networks with distributed heat pumps have demonstrated their capability to exploit renewable and waste heat sources in the urban environment. Therefore, they are considered a promising infrastructure to help decarbonize the building sector. As their main operating cost is the electricity purchased by the utility for heat pumps and circulation pumps, this work investigates whether a Renewable Energy Community could help mitigate such cost by sharing electricity produced by local photovoltaic (PV) systems. The research relies on computer simulations performed with both physical and statistical models for the evaluation of electrical load profiles at the district level. Results show that due to the different seasonality between heating demand and PV production, the increase in self-consumption due to the distributed heat pumps is lower than 10%. The use of batteries does not seem convenient for the same reason. The environmental benefit of the proposed system is evident, with CO2 emissions reduced by 72–80% compared to the current situation depending on PV power installed. It also emerged that PV sharing significantly improves the self-consumption at the district level, in particular when the installed PV power is limited (+45%). In conclusion, results suggest that current incentives on PV-sharing make Renewable Energy Communities a viable option to improve the techno-economic performance of fifth-generation district heating and cooling networks.

17 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
DQDavide Quaggiotto
Davide Quaggiotto
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
GEGiuseppe Emmi
Giuseppe Emmi
MCMichele De Carli
Michele De Carli
LPLuc Pockele
Luc Pockele
Adriana BernardiAdriana Bernardi
Adriana Bernardi
In this study, the thermal behavior of the coaxial and double U borehole heat exchangers was investigated using numerical simulations in both the long- and short-term. As a reference for borehole heat exchanger specifications, the existing coaxial and double U probes of a geothermal heat pump installed within the Horizon 2020 research project named “Cheap GSHPs” were considered. Nine years of simulations revealed that when borehole heat exchangers are subjected to a balanced thermal load, and intermittent operating modes of the ground source heat pump system are set, the coaxial pipes’ configuration provides better thermal performance due to the higher thermal capacitance of the heat-carrier fluid and the lower borehole thermal resistance. The analysis was conducted considering two different types of ground with different thermal conductivity values. As result, the more conductive ground type highlights the higher yield of the coaxial probe.

16 September 2019 in Energies
Verified
Journal Article
Open access
PDF file
sergio Bobbosergio Bobbo
sergio Bobbo
LFLaura Fedele
Laura Fedele
MCMarco Curcio
Marco Curcio
ABAnna Bet
Anna Bet
MCMichele De Carli
Michele De Carli
ABAdriana Bernardi
Adriana Bernardi
In the European Union (EU), buildings are responsible for about 40% of the total final energy consumption, and 36% of the European global CO2 emissions. The European Commission released directives to push for the enhancement of the buildings energy performance and identified, beside the retrofit of the current building stock, Heating, Ventilation, and Air Conditioning (HVAC) systems as the other main way to increase renewable energy sharing and overall building energy efficiency. For this purpose, Ground Source Heat Pumps (GSHPs) represent one of the most interesting technologies to provide energy for heating, cooling, and domestic water production in residential applications, ensuring a significant reduction (e.g., up to 44% compared with air-source heat pumps) of energy consumption and the corresponding emissions. At present, GSHPs mainly employ the refrigerant R410A as the working fluid, which has a Global Warming Potential (GWP) of 2087. However, following the EU Regulation No. 517/2014 on fluorinated greenhouse gases, this high GWP refrigerant will have to be substituted for residential applications in the next years. Thus, to increase the sustainability of GSHPs, it is necessary to identify short time alternative fluids with lower GWP, before finding medium-long term solutions characterized by very low GWP. This is one of the tasks of the UE project "Most Easy, Efficient, and Low-Cost Geothermal Systems for Retrofitting Civil and Historical Buildings" (acronym GEO4CIVHIC). Here, a thorough thermodynamic analysis, based on both energy and exergy analysis, will be presented to perform a comparison between different fluids as substitutes for R410A, considered as the benchmark for GSHP applications. These fluids have been selected considering their lower flammability with respect to hydrocarbons (mainly R290), that is one of the main concerns for the companies. A parametric analysis has been performed, for a reversible GSHP cycle, at various heat source and sink conditions, with the aim to identify the fluid giving the best energetic performance and to evaluate the distribution of the irreversibilities along the cycle. Considering all these factors, R454B turned out to be the most suitable fluid to use in a ground source heat pump, working at given conditions. Special attention has been paid to the compression phase and the heat transfer in evaporator and condenser.

7 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
PGPierpaolo Garavaso
Pierpaolo Garavaso
Fabio BignucoloFabio Bignucolo
Fabio Bignucolo
JVJacopo Vivian
Jacopo Vivian
GAGiulia Alessio
Giulia Alessio
MCMichele De Carli
Michele De Carli
Energy communities (ECs) are becoming increasingly common entities in power distribution networks. To promote local consumption of renewable energy sources, governments are supporting members of ECs with strong incentives on shared electricity. This policy encourages investments in the residential sector for building retrofit interventions and technical equipment renovations. In this paper, a general EC is modeled as an energy hub, which is deemed as a multi-energy system where different energy carriers are converted or stored to meet the building energy needs. Following the standardized matrix modeling approach, this paper introduces a novel methodology that aims at jointly identifying both optimal investments (planning) and optimal management strategies (operation) to supply the EC’s energy demand in the most convenient way under the current economic framework and policies. Optimal planning and operating results of five refurbishment cases for a real multi-family building are found and discussed, both in terms of overall cost and environmental impact. Simulation results verify that investing in building thermal efficiency leads to progressive electrification of end uses. It is demonstrated that the combination of improvements on building envelope thermal performances, photovoltaic (PV) generation, and heat pump results to be the most convenient refurbishment investment, allowing a 28% overall cost reduction compared to the benchmark scenario. Furthermore, incentives on shared electricity prove to stimulate higher renewable energy source (RES) penetration, reaching a significant reduction of emissions due to decreased net energy import.