Marek Zemek

Mr. Marek Zemek

Central European Institute of Technology, Brno University of Technology; Purkyňova 123, 61200 Brno, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2021 in Measurement Science and Technology
Verified
Journal Article
Open access
VJVictory A J Jaques
Victory A J Jaques
Anton Du PlessisAnton Du Plessis
Anton Du Plessis
Marek ZemekMarek Zemek
Marek Zemek
JSJakub Salplachta
Jakub Salplachta
ZSZuzana Stubianová
Zuzana Stubianová
Jozef KaiserJozef Kaiser
Jozef Kaiser
X-ray computed tomography is a common tool for non-destructive testing and analysis. One major application of this imaging technique is 3D porosity identification and quantification, which involves image segmentation of the analysed dataset. This segmentation step, which is most commonly performed using a global thresholding algorithm, has a major impact on the results of the analysis. Therefore, a thorough description of the workflow and a general uncertainty estimation should be provided alongside the results of porosity analysis to ensure a certain level of confidence and reproducibility. A review of current literature in the field shows that a sufficient workflow description and an uncertainty estimation of the result are often missing. This work provides recommendations on how to report the processing steps for porosity evaluation in computed tomography data using global thresholding, and reviews the methods for the estimation of the general uncertainty in porosity measurements.

30 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
VGVeronika Gajdosova
Veronika Gajdosova
BSBeata Strachota
Beata Strachota
ASAdam Strachota
Adam Strachota
DMDanuse Michalkova
Danuse Michalkova
SKSabina Krejcikova
Sabina Krejcikova
Miroslav SloufMiroslav Slouf
Miroslav Slouf
We report a reproducible preparation and characterization of highly homogeneous thermoplastic starch/pol(ε-caprolactone) blends (TPS/PCL) with a minimal thermomechanical degradation and co-continuous morphology. These materials would be suitable for biomedical applications, specifically for the local release of antibiotics (ATB) from the TPS phase. The TPS/PCL blends were prepared in the whole concentration range. In agreement with theoretical predictions based on component viscosities, the co-continuous morphology was found for TPS/PCL blends with a composition of 70/30 wt.%. The minimal thermomechanical degradation of the blends was achieved by an optimization of the processing conditions and by keeping processing temperatures as low as possible, because higher temperatures might damage ATB in the final application. The blends’ homogeneity was verified by scanning electron microscopy. The co-continuous morphology was confirmed by submicron-computed tomography. The mechanical performance of the blends was characterized in both microscale (by an instrumented microindentation hardness testing; MHI) and macroscale (by dynamic thermomechanical analysis; DMTA). The elastic moduli of TPS increased ca four times in the TPS/PCL (70/30) blend. The correlations between elastic moduli measured by MHI and DMTA were very strong, which implied that, in the future studies, it would be possible to use just micromechanical testing that does not require large specimens.

1 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JSJakub Salplachta
Jakub Salplachta
TZTomáš Zikmund
Tomáš Zikmund
Marek ZemekMarek Zemek
Marek Zemek
ABAdam Břínek
Adam Břínek
YTYoshihiro Takeda
Yoshihiro Takeda
Jozef KaiserJozef Kaiser
Jozef Kaiser
In this article, we introduce a new ring artifacts reduction procedure that combines several ideas from existing methods into one complex and robust approach with a goal to overcome their individual weaknesses and limitations. The procedure differentiates two types of ring artifacts according to their cause and character in computed tomography (CT) data. Each type is then addressed separately in the sinogram domain. The novel iterative schemes based on relative total variations (RTV) were integrated to detect the artifacts. The correction process uses the image inpainting, and the intensity deviations smoothing method. The procedure was implemented in scope of lab-based X-ray nano CT with detection systems based on charge-coupled device (CCD) and scientific complementary metal–oxide–semiconductor (sCMOS) technologies. The procedure was then further tested and optimized on the simulated data and the real CT data of selected samples with different compositions. The performance of the procedure was quantitatively evaluated in terms of the artifacts’ detection accuracy, the comparison with existing methods, and the ability to preserve spatial resolution. The results show a high efficiency of ring removal and the preservation of the original sample’s structure.

28 January 2025 in Journal of Hazardous Materials
Verified
Journal Article
Open access
VPViktória Parobková
Viktória Parobková
LMLukáš Maleček
Lukáš Maleček
Marek ZemekMarek Zemek
Marek Zemek
Gabriela KalčíkováGabriela Kalčíková
Gabriela Kalčíková
MVMichaela Vykypělová
Michaela Vykypělová
JKJozef Kaiser
Jozef Kaiser
The analysis of microplastics with current spectroscopic and pyrolytic methods is reaching its limits, especially with regard to detailed spatial distribution in biological tissues. This limitation hampers a comprehensive understanding of the effects of microplastics on organisms. Therefore, there is a pressing need to expand the analytical approaches to study microplastics in biota. In this context, the aim of this study was to test the applicability of non-destructive 3D imaging using X-ray micro-computed tomography (microCT) for the detection of microplastics in fish. Zebrafish (Danio rerio) were gavaged with polyethylene spherical microplastics (30-110 μm) and the distribution of microplastics in the gut was investigated using microCT. The results showed that the particle size distribution determined by microCT closely matched the data from conventional laser diffraction analysis. In addition, microCT was able to detect microplastics in spiked fish tissue and provide precise localization data by tracing particles of known type and shape. MicroCT offers a novel approach for tracking microplastics in organisms and enables accurate sizing without compromising the integrity of the tissue under investigation. It therefore represents a valuable addition to spectroscopic methods, which are widely used for the detection of microplastics based on their chemical composition but do not provide data on their spatial distribution.

1 February 2020 in e-Journal of Nondestructive Testing
Verified
Journal Article
Open access
PDF file
B(Brno University of Technology (BUT)
Brno University of Technology (BUT)
Marek ZemekMarek Zemek
Marek Zemek
PBPavel Blažek
Pavel Blažek
C(Czech Metrology Institute (CMI)
Czech Metrology Institute (CMI)
JŠJan Šrámek
Jan Šrámek
Jozef KaiserJozef Kaiser
Jozef Kaiser
In cone-beam X-ray computed tomography (CT), distances between the source, object, and detector influence the visual fidelity and voxel size of a reconstructed volume. Calibration using reference objects is an appropriate tool for preventing errors in the estimates of these distances. There is, however, a lack of such objects for high-resolution systems with a small field of view (FoV). In this work, we propose a method to measure the distances mentioned above, improving the determination of voxel size. We use a custom reference object suitable for a FoV of around one millimeter. Many approaches have been developed for this calibration task and discussed in the literature, but none apply to CT scanners with a small FoV and a cone-beam magnification close to one. The proposed method thus aims to provide a calibration procedure for such devices. A Rigaku Nano3DX CT scanner has been calibrated through this method and used for practical validation of the method's accuracy. Results have shown that this approach allows for accurate calibration, which leads to improvements in reconstruction quality and accuracy of voxel size determination.

1 January 2024 in Acta Palaeontologica Polonica
Verified
Journal Article
Open access
PTPetra Tonarová
Petra Tonarová
TSThomas Suttner
Thomas Suttner
OHOlle Hints
Olle Hints
YLYan Liang
Yan Liang
Marek ZemekMarek Zemek
Marek Zemek
EKErika Kido
Erika Kido