Mariela Anaguano-Marcillo

Ms. Mariela Anaguano-Marcillo

Faculty of Engineering, Pontificia Universidad Católica del Ecuador, Quito, Pichincha, Ecuador
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJorge Mayanquer
Jorge Mayanquer
Mariela Anaguano-MarcilloMariela Anaguano-Marcillo
Mariela Anaguano-Marcillo
Nicolas Fernando JativaNicolas Fernando Jativa
Nicolas Fernando Jativa
Jorge David Albuja-SánchezJorge David Albuja-Sánchez
Jorge David Albuja-Sánchez
The Marchetti Dilatometer test is a non-destructive in situ test that can be used to determine the geotechnical properties of soils. This paper presents the results of a study that investigated the correlations between the parameters obtained from the Marchetti Dilatometer test and geomechanical parameters for soft soils, mainly organic soils, obtained in the laboratory. The study was conducted in the El Garrochal sector in Southern Quito, Ecuador. The results of the study showed that there are significant correlations between the Marchetti Dilatometer test and the undrained shear strength, modulus of elasticity, and density of soil. The equations that were developed in this study can be used to estimate these geomechanical parameters from the results of the Marchetti Dilatometer test for the South Quito sector, which are valuable for geotechnical engineers to design structures in these types of soils. The equations that were developed in this study can be used to improve the accuracy of the design of these structures.

26 May 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Amelia Montero BernabéAmelia Montero Bernabé
Amelia Montero Bernabé
ARAriel Román
Ariel Román
Jorge David Albuja-SánchezJorge David Albuja-Sánchez
Jorge David Albuja-Sánchez
Mariela Anaguano-MarcilloMariela Anaguano-Marcillo
Mariela Anaguano-Marcillo
Nicolay Bernardo Yanchapanta GómezNicolay Bernardo Yanchapanta Gómez
Nicolay Bernardo Yanchapanta Gómez
LRLuis Tinerfe Hernández Rodríguez
Luis Tinerfe Hernández Rodríguez
The objective of this work is to study the physical and mechanical behavior of concrete with the addition of 0.5% and 1.0% of coconut fibers subjected to two chemical treatments in order to reduce their degradation and optimize their use in the elaboration of concrete specimens, which must comply with the standards of the American Society for Testing of Materials (ASTM), the American Concrete Institute (ACI) and the Instituto Ecuatoriano de Normalización (INEN). The coconut fibers were obtained from the raw material by hand and cut to a length of 4 cm. Subsequently, the coconut fibers were subjected to two chemical treatments: The first treatment is the immersion of the coconut fibers in 4% sodium hydroxide (NaOH) solution and the second treatment, the coconut fibers were immersed in gum arabic to consequently coat them with silica fume. A particular dosage was carried out with a proportion of 0.5% and 1.0% volume of coconut fiber for the two chemical treatments, replacing the volume of coarse aggregate. Simple concrete joists were made without fiber and with the post-treatment coconut fibers, which were subjected to flexural tests. The results indicated that the best chemical treatment is sodium hydroxide with a concentration of 4% and 1.0% coconut fiber for strengths of 210 kg/cm² and 240 kg/cm². In general, the joists with coconut fiber treated with sodium hydroxide outperformed the fibers treated with gum arabic and silica fume.