Marisa Avvedimento

Dr. Marisa Avvedimento

University of Naples Federico II, Naples, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2024 in Circulation
Verified
Journal Article
Closed access
JRJosep Rodés-Cabau
Josep Rodés-Cabau
HRHenrique Ribeiro
Henrique Ribeiro
SMSiamak Mohammadi
Siamak Mohammadi
VSVicenç Serra
Vicenç Serra
TATalal Al-Atassi
Talal Al-Atassi
OIon behalf of the VIVA (Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement for Treating Elderly Patients With Severe Aortic Stenosis and Small Aortic Annuli) Trial Investigators
on behalf of the VIVA (Transcatheter Aortic Valve Replacement Versus Surgical Aortic Valve Replacement for Treating Elderly Patients With Severe Aortic Stenosis and Small Aortic Annuli) Trial Investigators
BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%–3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4–22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P =0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P =1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P =0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1–4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P =0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P =0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P =0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03383445.

1 November 2021 in Progress in Cardiovascular Diseases
Verified
Journal Article
Closed access
MAMarisa Avvedimento
Marisa Avvedimento
GTGilbert H.L. Tang
Gilbert H.L. Tang

4 February 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
MCMario Enrico Canonico
Mario Enrico Canonico
CSCiro Santoro
Ciro Santoro
MAMarisa Avvedimento
Marisa Avvedimento
GGGiuseppe Giugliano
Giuseppe Giugliano
Giulia Elena MandoliGiulia Elena Mandoli
Giulia Elena Mandoli
GEGiovanni Esposito
Giovanni Esposito
Acute thrombotic events can unveil occult cancer, as they are its first manifestation in about 20 to 30% of all cases. Malignancy interacts in an intricate way with the hemostatic system, promoting both thrombosis and bleeding. The main pathway involved in these reactions involves the activation of tumor-associated procoagulant factors, which eventually results in clot formation. The clinical manifestation of cancer-related thrombotic events mainly involves the venous side, and manifests in a broad spectrum of conditions, including unusual sites of venous thrombosis. The selection of patients who have a balanced risk–benefit profile for management of anticoagulation is complex, given individual patient goals and preferences, different prognosis of specific cancers, common comorbidities, potential drug–drug interactions, underweight states, and the competing risks of morbidity and mortality. Anticoagulant treatment in cancer settings is broadly debated, considering the potential application of direct oral anticoagulants in both thromboprophylaxis and secondary prevention, having demonstrated its efficacy and safety compared to conventional treatment. This review aims to provide a brief overview of the pathophysiology and management of cancer-related thrombosis, summarizing the results obtained in recent clinical trials.

29 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
RMRachele Manzo
Rachele Manzo
Federica IlardiFederica Ilardi
Federica Ilardi
DNDalila Nappa
Dalila Nappa
AMAndrea MARIANI
Andrea MARIANI
Domenico AngellottiDomenico Angellotti
Domenico Angellotti
GEGiovanni Esposito
Giovanni Esposito
Echocardiography represents the most important diagnostic tool in the evaluation of aortic stenosis. The echocardiographic assessment of its severity should always be performed through a standardized and stepwise approach in order to achieve a comprehensive evaluation. The latest technical innovations in the field of echocardiography have improved diagnostic accuracy, guaranteeing a better and more detailed evaluation of aortic valve anatomy. An early diagnosis is of utmost importance since it shortens treatment delays and improves patient outcomes. Echocardiography plays a key role also in the evaluation of all the structural changes related to aortic stenosis. Detailed evaluation of subtle and subclinical changes in left ventricle function has a prognostic significance: scientific efforts have been addressed to identify the most accurate global longitudinal strain cut-off value able to predict adverse outcomes. Moreover, in recent years the role of artificial intelligence is increasingly emerging as a promising tool able to assist cardiologists in aortic stenosis screening and diagnosis, especially by reducing the rate of aortic stenosis misdiagnosis.

Verified
Journal Article
Open access
PDF file
ALAttilio Leone
Attilio Leone
FSFiorenzo Simonetti
Fiorenzo Simonetti
MAMarisa Avvedimento
Marisa Avvedimento
Domenico AngellottiDomenico Angellotti
Domenico Angellotti
MMMaddalena Immobile Molaro
Maddalena Immobile Molaro
RPRaffaele Piccolo
Raffaele Piccolo
New-generation drug-eluting stents (DESs) represent the standard of care for patients undergoing percutaneous coronary intervention (PCI). Recent iterations in DES technology have led to the development of newer stent platforms with a further reduction in strut thickness. This new DES class, known as ultrathin struts DESs, has struts thinner than 70 µm. The evidence base for these devices consists of observational data, large-scale meta-analyses, and randomized trials with long-term follow-up, which have been conducted to investigate the difference between ultrathin struts DESs and conventional new-generation DESs in a variety of clinical settings and lesion subsets. Ultrathin struts DESs may further improve the efficacy and safety profile of PCI by reducing the risk of target-lesion and target-vessel failures in comparison to new-generation DESs. In this article, we reviewed device characteristics and clinical data of the Orsiro (Biotronik, Bülach, Switzerland), Coroflex ISAR (B. Braun Melsungen, Germany), BioMime (Meril Life Sciences Pvt. Ltd., Gujarat, India), MiStent (MiCell Technologies, USA), and Supraflex (Sahajanand Medical Technologies, Surat, India) sirolimus-eluting stents.

30 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MAMarisa Avvedimento
Marisa Avvedimento
AFAnna Franzone
Anna Franzone
ALAttilio Leone
Attilio Leone
RPRaffaele Piccolo
Raffaele Piccolo
DCDomenico Simone Castiello
Domenico Simone Castiello
GEGiovanni Esposito
Giovanni Esposito
(1) Aims: We sought to assess the impact of the extent of cardiac damage on survival among real-world patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). (2) Methods: A staging classification was applied to 262 patients from the EffecTAVI Registry at baseline and re-assessed within 30-days after TAVI. The primary endpoint of the study was all-cause mortality at 1-year. Secondary endpoints included cerebrovascular accident, myocardial infarction, permanent pacemaker implantation, endocarditis, and re-hospitalization for all causes. (3) Results: At baseline, 23 (8.7%) patients were in Stage 0/1 (no cardiac damage/left ventricular damage), 106 (40.4%) in Stage 2 (left atrial or mitral valve damage), 59 (22.5%) in Stage 3 (pulmonary vasculature or tricuspid valve damage) and 74 (28.3%) in Stage 4 (right ventricular damage). At 30-days after TAVI, a lower prevalence of advanced stages of cardiac damage than baseline, mainly driven by a significant improvement in left ventricular diastolic parameters and right ventricular function, was reported. At 1-year, a stepwise increase in mortality rates was observed according to staging at baseline: 4.3% in Stage 0/1, 6.6% in Stage 2, 18.6% in Stage 3 and 21.6% in Stage 4 (p = 0.08). No differences were found in secondary endpoints. (4) Conclusions: TAVI has an early beneficial impact on the left ventricular diastolic and right ventricular function. However, the extent of cardiac damage at baseline significantly affects the risk of mortality at 1-year after the procedure.