Background: Cortical spreading depolarization (CSD) is a massive neuro-glial depolarization wave, which propagates across the cerebral cortex. In stroke, CSD is a necessary and ubiquitous mechanism for the development of neuronal lesions that initiates in the ischemic core and propagates through the penumbra extending the tissue injury. Although CSD propagation induces dramatic changes in cerebral blood flow, the vascular responses in different ischemic regions and their consequences on reperfusion and recovery remain to be defined. Methods: Ischemia was performed using the thrombin model of stroke and reperfusion was induced by r-tPA (recombinant tissue-type plasminogen activator) administration in mice. We used in vivo electrophysiology and laser speckle contrast imaging simultaneously to assess both electrophysiological and hemodynamic characteristics of CSD after ischemia onset. Neurological deficits were assessed on day 1, 3, and 7. Furthermore, infarct sizes were quantified using 2,3,5-triphenyltetrazolium chloride on day 7. Results: After ischemia, CSDs were evidenced by the characteristic propagating DC shift extending far beyond the ischemic area. On the vascular level, we observed 2 types of responses: some mice showed spreading hyperemia confined to the penumbra area (penumbral spreading hyperemia) while other showed spreading hyperemia propagating in the full hemisphere (full hemisphere spreading hyperemia). Penumbral spreading hyperemia was associated with severe stroke-induced damage, while full hemisphere spreading hyperemia indicated beneficial infarct outcome and potential viability of the infarct core. In all animals, thrombolysis with r-tPA modified the shape of the vascular response to CSD and reduced lesion volume. Conclusions: Our results show that different types of spreading hyperemia occur spontaneously after the onset of ischemia. Depending on their shape and distribution, they predict severity of injury and outcome. Furthermore, our data show that modulating the hemodynamic response to CSD may be a promising therapeutic strategy to attenuate stroke outcome.
Brain activity relies on a steady supply of blood glucose. Astrocytes express glucose transporter 1 (GLUT1), considered their primary route for glucose uptake to sustain metabolic and antioxidant support for neurons. While GLUT1 deficiency causes severe developmental impairments, its role in adult astrocytes remains unclear. Here, we show that astrocytes and neurons tolerate the inducible, astrocyte-specific deletion of GLUT1 in adulthood. Sensorimotor and memory functions remain intact in male GLUT1 cKO mice, indicating that GLUT1 loss does not impair behavior. Despite GLUT1 loss, two-photon glucose sensor imaging reveals that astrocytes maintain normal resting glucose levels but exhibit a more than two-fold increase in glucose consumption, indicating enhanced metabolic activity. Notably, male GLUT1 cKO mice display reduced infarct volumes following stroke, suggesting a neuroprotective effect of increased astrocytic glucose metabolism. Our findings reveal metabolic adaptability in astrocytes, ensuring glucose uptake and neuronal support despite the absence of their primary transporter.
Avoidance of environmental dangers depends on nociceptive topognosis, or the ability to localize painful stimuli. This is proposed to rely on somatotopic maps arising from topographically organized point-to-point connections between the body surface and the CNS. To determine the role of topographic organization of spinal ascending projections in nociceptive topognosis, we generated a conditional knockout mouse lacking expression of the netrin1 receptor DCC in the spinal cord. These mice have an increased number of ipsilateral spinothalamic connections and exhibit aberrant activation of the somatosensory cortex in response to unilateral stimulation. Furthermore, spinal cord-specific Dcc knockout animals displayed mislocalized licking responses to formalin injection, indicating impaired topognosis. Similarly, humans with DCC mutations experience bilateral sensation evoked by unilateral somatosensory stimulation. Collectively, our results constitute functional evidence of the importance of topographic organization of spinofugal connections for nociceptive topognosis.
24 January 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
The small animal fast insert for mRi (SAFIR) positron emission tomography insert was proposed for quantitative dynamic acquisition inside a preclinical 7T magnetic resonance imaging scanner to study kinetics of short-lived tracers. For this purpose, the SAFIR readout should be capable of handling high count rates and achieving excellent timing performance. We evaluated one of the available application specific integrated circuits (ASICs) for SiPM readout, namely SiPM timing chip (STiC) version 3.1. In this paper, we show the performances of the SAFIR PET detector with the STiC ASIC readout. The SAFIR PET detector consists of an 8 x 8 array of lutetium yttrium oxyorthosilicate 2.1 mm x 2.1 mm x 12 mm crystals coupled, with optical grease, to an 8 x 8 array of SiPMs with a 2.0 mm x 2.0 mm photo-sensitive area. Signals from the individual SiPM channels were digitized by the STiC ASIC. Hit's arrival time and time-over-threshold (TOT) were recorded into time stamps with 50.2-ps least significant bit. We obtained an average energy resolution of 18.5% full width at half maximum (FWHM) at 511-keV photopeak after TOT nonlinearity correction and an average coincidence resolving time resolution of 244-ps FWHM with time walk correction that satisfy our requirements specification on the detector performance.
18 March 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
The SAFIR collaboration is currently developing a high-rate positron emission tomography (PET) insert to study fast kinetic processes in small animals. Our insert is designed for simultaneous image acquisition with a preclinical 7T magnetic resonance (MR) imaging device. In contrast to existing preclinical PET scanners and inserts, our hardware is optimized for high-rate measurements with source activities up to 500MBq. As a first step, the SAFIR Prototype insert was constructed. This already incorporates the final components, but has a reduced axial field-of-view (35.6 mm). We use lutetium-yttrium oxyorthosilicate crystals (2.12 × 2.12 × 13 mm3) one-to-one coupled to silicon photomultipliers. All analogue signals are digitized within the insert. We use 49 MR-compatible DC-DC converters in the insert to provide the power to all readout electronics. After shimming, no degradation of the homogeneity of the static B0 field in the MR scanner was observed. During full operation we saw a minor reduction in the signal-to-noise ratio of theMRdata of 4.9%. With a low activity point source (22Na 0.65MBq) we obtained a coincidence energy resolution of 13.8% (FWHM) and a coincidence timing resolution of 194 ps (FWHM). First PET/MR rat brain and high-rate mouse cardiac images (84.9MBq) are shown in this work.
About Me
Institute of Pharmacology and Toxicology
University of Zurich
Institute of Pharmacology and Toxicology
University of Zurich