High-resolution positron emission tomography (PET) scanners often use pixelated scintillator arrays with lightsharing for the detection of gamma rays. The aim of this paper is to enhance the spatial re.solution of such a pixelated scintillator detector by filtering out events with multiple interactions of gamma rays in the scintillator based on the measured light distributions. To develop and evaluate such enhancements in spatial resolution, we measure the point spread function (PSF) of our detector directly using a thinly collimated gamma ray beam setup, and then later verify their benefits on a full preclinical PET system with a hotrod phantom. The scintillator detector comprises a 30 × 30 × 12 mm 3 lutetium-yttrium oxyorthosilicate array with a pitch of 1 mm coupled to a digital silicon photomultiplier array via a 2-mm lightguide. We use a center of gravity algorithm for the crystal identification; however, the proposed filters are independent of the crystal identification algorithm. Investigating a single detector with our collimated gamma beam, we reject 15% of the events as multiple interaction while improving the crystal identification efficiency from 60.0% to 68.3% and the 90th-percentile diameter of the PSF from 7.88 to 3.98 mm. On system level, we analyze a line profile through two different rod sizes in a hotrod phantom. The filters reject 32% of the coincidences and increase the peak-to-valley ratio by 8% (0.9-mm rods) and by 18% (1.2-mm rods).
18 March 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
The SAFIR collaboration is currently developing a high-rate positron emission tomography (PET) insert to study fast kinetic processes in small animals. Our insert is designed for simultaneous image acquisition with a preclinical 7T magnetic resonance (MR) imaging device. In contrast to existing preclinical PET scanners and inserts, our hardware is optimized for high-rate measurements with source activities up to 500MBq. As a first step, the SAFIR Prototype insert was constructed. This already incorporates the final components, but has a reduced axial field-of-view (35.6 mm). We use lutetium-yttrium oxyorthosilicate crystals (2.12 × 2.12 × 13 mm3) one-to-one coupled to silicon photomultipliers. All analogue signals are digitized within the insert. We use 49 MR-compatible DC-DC converters in the insert to provide the power to all readout electronics. After shimming, no degradation of the homogeneity of the static B0 field in the MR scanner was observed. During full operation we saw a minor reduction in the signal-to-noise ratio of theMRdata of 4.9%. With a low activity point source (22Na 0.65MBq) we obtained a coincidence energy resolution of 13.8% (FWHM) and a coincidence timing resolution of 194 ps (FWHM). First PET/MR rat brain and high-rate mouse cardiac images (84.9MBq) are shown in this work.
(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7 Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of and an inner diameter of 114. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system’s Coincidence Resolving Time (CRT) and energy resolution are between separate-uncertainty and separate-uncertainty Full Width at Half Maximum (FWHM) at low activity and separate-uncertainty and separate-uncertainty FWHM at 550, respectively. The peak sensitivity is ∼. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300. Based on features visible in the acquired images, we estimate the spatial resolution to be ∼2 in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500.
This paper presents the development of two mobile brain Positron Emission Tomography (PET) scanners under the PETITION project, designed for Intensive Care Units (ICUs) and Proton Beam Therapy (PBT) applications. The ICU scanner facilitates bedside imaging for critically ill patients, while the PBT scanner enables undisturbed proton beam irradiation during imaging. Key aspects of the hardware design, including modular detectors and electromagnetic interference considerations, are discussed along with preliminary performance evaluations. Operational testing, employing a 22Na source and a hot-rod phantom, was conducted to determine the timing resolution (548 ), energy resolution (11.4%) and a qualitative spatial resolution (around 2.2 ). Our study presents findings on the ICU PET scanner’s electromagnetic emissions measured in a controlled EMC testing facility, where all the emissions tests performed comply with the standard EN 60601-1-2 (radiated emissions 15 dB below regulatory limits in the frequency range of 30 to 1 G).
13 December 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment