Wearable electronic sensor was prepared on a light and flexible substrate. The breathing sensor has a broad assumption and great potential for portable devices in wearable technology. In the present work, the application of a flexible thermoplastic polyurethane/multiwalled carbon nanotubes (TPU/MWCNTs) strain sensor was demonstrated. This composite was prepared by a novel technique using a thermoplastic filtering membrane based on electrospinning technology. Aqueous dispersion of MWCNTs was filtered through membrane, dried and then welded directly on a T-shirt and encapsulated by a thin silicone layer. The sensing layer was also equipped by electrodes. A polymer composite sensor is capable of detecting a deformation by changing its electrical resistance. A T-shirt was capable of analyzing a type, frequency and intensity of human breathing. The sensitivity to the applied strain of the sensor was improved by the oxidation of MWCNTs by potassium permanganate (KMnO4) and also by subsequent application of the prestrain.
A wearable and stretchable strain sensor with a gauge factor above 23 was prepared using a simple and effective technique. Conducting nanocomposite strands were prepared from styrene-b-(ethylene-co-butylene)-b-styrene triblock copolymer (SEBS) and carbon black (CB) through a solvent-processing method that uses a syringe pump. This novel nanocomposite preparation technique is a straightforward and cost-effective process and is reported in the literature for the first time. The work included two stages: the flexible nanocomposite preparation stage and the piezoresistive sensor stage. Depending on its molecular structure, the thermoelastic polymer SEBS is highly resilient to stress and strain. The main aim of this work is to fabricate a highly flexible and piezoresistive nanocomposite fibre/strand. Among the prepared composites, a composite corresponding to a composition just above the percolation threshold was selected to prepare the strain sensor, which exhibited good flexibility and conductivity and a large piezoresistive effect that was linearly dependent on the applied strain. The prepared nanocomposite sensor was stitched onto a sports T-shirt. Commercially available knee and elbow sleeves were also purchased, and the nanocomposite SEBS/CB strands were sewn separately on the two sleeves. The results showed a high sensitivity of the sensing element in the case of breathing activity (normal breathing, a 35% change, and deep breathing at 135%, respectively). In the case of knee and elbow movements, simultaneous measurements were performed and found that the sensor was able to detect movement cycles during walking.
With the growing public interest in edible insects, breeders are forced to increase the volume of production and shorten the life cycle of farmed insects. The exact composition of the feed is the know-how of each manufacturer. The aim of this work was to determine the general impact of individual conventional types of feed (bran, whey, raw ware potatoes) on the life cycle rate of Tenebrio molitor (TM), larval mortality and the content of fats, fatty acids and nitrogenous substances in larvae and their excrements. For the reasons of sustainability of the state of nature and waste disposal, polystyrene foam was added to the experiment as feed. The experiment was performed in two phases—rearing for 21 weeks and 5 weeks. The nitrogen content was determined using the Kjeldahl method (ISO 1871: 2009), the fat content by the Soxhlet method and the fatty acid profile using a gas chromatograph with a flame ionization detector (FID). The results of the work show that the basis of the TM feed is wheat bran, not only due to the observed low larval mortality (45% over 21 weeks) and their optimal nutritional value (nitrogenous substances 53.6% DM, fat 37.1% DM, the highest total fatty acid content) but also due to the higher speed of TM development. Lower larval mortality during rearing was found when feeding dried whey and raw ware potatoes, but the development cycle rate was low. This confirmed that the bran as a feed allowed a fast life cycle with good larval nutritional parameters. From a nutritional and reproductive point of view, TM appeared to be a suitable alternative to animal production. Polystyrene as a feed, tested for biodegradation by TM larvae, caused the highest larval mortality (75% in 21 weeks). However, the content of nitrogenous substances in the larvae increased to 69.77%, in the excrement, it even increased to 82.68%, and there was no cannibalism among the larvae. The work thus demonstrated the possibility of biodegradation of polystyrene using TM larvae with an increase in nitrogenous substances in both larvae and excrement.
The versatile properties of a nanopaper consisting of a porous network of multi-walled carbon nanotubes were applied to enhance the mechanical and electrical properties of a thermosetting epoxy polymer. The embedded nanopaper proved useful both in the monitoring of the curing process of the epoxy resin by the self-regulating Joule heating and in the supervising of tensile deformations of the composite by detecting changes in its electrical resistance. When heated by Joule heating above its glass transition temperature, the embedded carbon nanotube nanopaper accelerated not only the modelling of the composites into various shapes, but also the shape recovery process, wherein the stress in the nanopaper was released and the shape of the composite reverted to its original configuration. Lastly, in comparison with its respective epoxy adhesive, the internally heated electro-conductive carbon nanotube nanopaper/epoxy composite not only substantially shortened curing time while retaining comparable strength of the adhesive bonding of the steel surfaces, but also enabled a release of such bonds by repeated application of DC current.