Ali Mehrizi-Sani

Prof. Ali Mehrizi-Sani

Virginia Polytechnic Institute and State University
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MYMehrdad Yazdanian
Mehrdad Yazdanian
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
The objective of this paper is to provide a review of distributed control and management strategies for the next generation power system in the context of microgrids. This paper also identifies future research directions. The next generation power system, also referred to as the smart grid, is distinct from the existing power system due to its extensive use of integrated communication, advanced components such as power electronics, sensing, and measurement, and advanced control technologies. At the same time, the need for increased number of small distributed and renewable energy resources can exceed the capabilities of an available computational resource. Therefore, the recent literature has seen a significant research effort on dividing the control task among different units, which gives rise to the development of several distributed techniques. This paper discusses features and characteristics of these techniques, and identifies challenges and opportunities ahead. The paper also discusses the relationship between distributed control and hierarchical control.

1 April 2010 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
RIReza Iravani
Reza Iravani
This paper introduces the potential-function based method for secondary (as well as tertiary) control of a microgrid, in both islanded and grid-connected modes. A potential function is defined for each controllable unit of the microgrid such that the minimum of the potential function corresponds to the control goal. The dynamic set points are updated, using communication within the microgrid. The proposed potential function method is applied for the secondary voltage control of two microgrids with single and multiple feeders. Both islanded and grid-connected modes are investigated. The studies are conducted in the time-domain, using the PSCAD/EMTDC software environment. The study results demonstrate feasibility of the proposed potential function method and viability of the secondary voltage control method for a microgrid.

18 April 2013 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HSH. Saad
H. Saad
JPJ. Peralta
J. Peralta
SDS. Dennetiere
S. Dennetiere
JMJ. Mahseredjian
J. Mahseredjian
JJJ. Jatskevich
J. Jatskevich
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
Voltage-source converter (VSC) technologies are rapidly evolving and increasing the range of applications in a variety of fields within the power industry. Existing two- and three-level VSC technologies are being superseded by the new modular multilevel converter (MMC) technology for HVDC applications. The computational burden caused by detailed modeling of MMC-HVDC systems in electromagnetic transient-type (EMT-type) programs complicates the simulation of transients when such systems are integrated into large networks. This paper develops and compares different types of models for efficient and accurate representation of MMC-HVDC systems. The results show that the use of a specific type of model will depend on the conducted analysis and required accuracy.

25 January 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
ISIman Sadeghkhani
Iman Sadeghkhani
MGMohamad Esmail Hamedani Golshan
Mohamad Esmail Hamedani Golshan
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
With high penetration of distributed energy resources, fault management strategy is of great importance for the distribution network operation. The objective of this paper is to propose a current and voltage limiting strategy to enhance fault ride-through (FRT) capability of inverter-based islanded microgrids (MGs) in which the effects of inverter control system and inverter topology (four/three-wire) are considered. A three-phase voltage-sourced inverter with multi-loop control system implemented in synchronous, stationary, and natural reference frames is employed in this paper for both four- and three-wire configurations. The proposed strategy provides high voltage and current quality during overcurrent conditions, which is necessary for sensitive loads. Several time-domain simulation studies are conducted to investigate the FRT capability of the proposed strategy against both asymmetrical and symmetrical faults. Moreover, the proposed method is tested on the CIGRE benchmark MG to demonstrate the effectiveness of the proposed limiting strategy.

20 March 2014 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MDM. Daryabak
M. Daryabak
SFS. Filizadeh
S. Filizadeh
JJJ. Jatskevich
J. Jatskevich
ADA. Davoudi
A. Davoudi
MSM. Saeedifard
M. Saeedifard
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
This paper presents an average-value model of a line-commutated converter-based HVDC system using dynamic phasors. The model represents the low-frequency dynamics of the converter and its ac and dc systems, and has lower computational requirements than a conventional electromagnetic-transient (EMT) switching model. The developed dynamic-phasor model is verified against an EMT model of the CIGRE HVDC Benchmark. Simulation results confirm the validity and accuracy of the average value model in predicting the low-frequency dynamics of the ac- and dc-side quantities. Merits and applicability limitations of the average model are highlighted.

28 March 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Stefan LeitnerStefan Leitner
Stefan Leitner
MYMehrdad Yazdanian
Mehrdad Yazdanian
Ali Mehrizi-SaniAli Mehrizi-Sani
Ali Mehrizi-Sani
AMAnnette Muetze
Annette Muetze
Several microgrid control strategies are proposed and studied in the literature. However, there are still gaps in improving their transient behavior and studying their stability. This paper uses small-signal analysis to explore the behavior of internal model-based current and voltage controllers by deriving a state-space model and performing eigenvalue and sensitivity analysis on an islanded inverter-based microgrid system. The results are compared with those of the same microgrid but with PI-based current and voltage controllers. Simulation case studies are performed in the PSCAD/EMTDC environment to compare the transient behavior of both methods. Results show that internal model-based controllers have superior eigenvalue patterns that lead to increased stability and improved transient behavior.