Jeong Hoon Moon

Dr. Jeong Hoon Moon

DH Innovation CO.,Ltd., Gwangju, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JMJeong Hoon Moon
Jeong Hoon Moon
PSPark Sung-jun
Park Sung-jun
SLSang Kil Lim
Sang Kil Lim
When driving the piezoelectric transducer (PT: piezo transducer), which is a key device, it is important for the ultrasonic system (using ultrasonic waves of 20 kHz or higher) to operate at a resonant frequency that can maximize the conversion of mechanical energy (vibration) from electrical energy. The resonant frequency of the PT changes during the actual operation according to the load fluctuations and environmental conditions. Therefore, to maintain a stable output in an ultrasonic system, it is essential to track the resonant frequency in a short time. In particular, fast resonant frequency tracking (RFT: resonant frequency tracking) is an important factor in the medical ultrasonic system, i.e., the system applied in this thesis. The reason is that in the case of a medical ultrasonic system, heat-induced skin necrosis, etc., may cause the procedure to be completed within a short period of time. Therefore, tracking the RFT time for maximum power transfer is an important factor; in this thesis, we propose a new high-speed RFT method. The proposed method finds the whole system resonance frequency by using the transient phenomenon (underdamped response characteristic) that appears in an impedance system, such as an ultrasonic generator, and uses this to derive the mechanical resonance frequency of the PT. To increase the accuracy of the proposed method, parameter fluctuations of the pressure of the PT, the equivalent circuit impedance analysis of the PT, and a MATLAB simulation were performed. Through this, the correlation between the resonance frequency of the ultrasonic system, including the LC filter with nonlinear characteristics and the mechanical resonance frequency of the PT, was analyzed. Based on the analyzed results, a method for tracking the mechanical resonance frequency that can transfer the maximum output to the PT is proposed in this thesis. Experiments show that using the proposed high-speed RFT method, the ultrasonic system can track the mechanical resonance frequency of the PT with high accuracy in a short time.

4 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJeong Hoon Moon
Jeong Hoon Moon
SLSang Kil Lim
Sang Kil Lim
JKJinhong Kim
Jinhong Kim
GKGeonil Kang
Geonil Kang
BKBeom-Hun Kim
Beom-Hun Kim
In an ultrasonic system, a piezoelectric transducer (PT) is a key component and contains a piezo element inside. In order to design and operate a system that uses a piezo element for its intended purpose, resonance analysis of the piezo element and an equivalent circuit analysis of the output stage of the ultrasonic system generator are required. Due to the characteristics of the equivalent circuit, a piezo element has multiple resonance points. Therefore, the system must be operated at the corresponding frequency by tracking the resonance frequency that suits the purpose of the system. In this study, the mechanical resonance frequency of the piezo element was analyzed and a method for operating the system at the corresponding frequency was studied. In order to operate a piezo element, a voltage-type inverter is used to apply a high-frequency AC (Alternating Current). Then, an LC filter is inserted into the output stage of the inverter, and the piezo element is finally located at the output stage of the LC filter. Therefore, when designing an LC filter, a design is required to optimize the performance of the piezo element. In this paper, we analyzed the resonance of a piezo element and the equivalent circuit of the generator output stage of an ultrasonic system for effective operation of an ultrasonic system. In addition, we proposed a method to estimate the characteristics of the entire mechanical resonance frequency range of a piezo element by using an LSTM (Long Short-Term Memory) model suitable for analyzing the nonlinear characteristics of a piezo element. The study on estimating the mechanical resonance frequency of a piezo element using an LSTM model was verified through MATLAB 2021b simulation and ultrasonic system experiments.

16 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJeong Hoon Moon
Jeong Hoon Moon
JKJinhong Kim
Jinhong Kim
JLJung Hwan Lee
Jung Hwan Lee
Digitally controlled DC–DC converters are vulnerable to sensor-side spoofing, motivating plant-level anomaly detection that respects the converter physics. We present a physics-informed LSTM (PI–LSTM) autoencoder for a 24→12 V buck converter. The model embeds discrete-time circuit equations as residual penalties and uses a fixed decision rule (τ=μ+3σ, N=3 consecutive samples). We study three voltage-sensing attacks (DC bias, fixed-sample delay, and narrowband noise) in MATLAB/Simulink. We then validate the detection path on a TMS320F28379 DSP. The detector attains F1 scores of 96.12%, 91.91%, and 97.50% for bias, delay, and noise (simulation); on hardware, it achieves 2.9–4.2 ms latency with an alarm-wise FPR of ≤1.2%. We also define a unified safety box for DC rail quality and regulation. In simulations, we evaluate a confusion index (CI) policy for safety-bounded performance adjustment. A operating point yields CI≈0.25 while remaining within the safety limits. In hardware experiments without CI actuation, the Vr,pp and IRR stayed within the limits, whereas the ±2% regulation window was occasionally exceeded under the delay attack (up to ≈2.8%). These results indicate that physics-informed detection is deployable on resource-constrained controllers with millisecond-scale latency and a low alarm-wise FPR, while the full hardware validation of CI-guided deception (safety-bounded performance adjustment) under the complete safety box is left to future work.