The aim of this study was to assess the validity and test-retest reliability of an inertial measurement unit (IMU) system for gait analysis. Twenty-four healthy subjects conducted a 6-min walking test and were instrumented with seven IMUs and retroreflective markers. A kinematic approach was used to estimate the initial and terminal contact events in real-time. Based on these events twelve spatio-temporal parameters (STP) were calculated. A marker based optical motion capture (OMC) system provided the reference. Event-detection rate was about 99%. Detection offset was below 0.017 s. Relative root mean square error (RMSE) ranged from 0.90% to 4.40% for most parameters. However, the parameters that require spatial information of both feet showed higher errors. Step length showed a relative RMSE of 6.69%. Step width and swing width revealed the highest relative RMSE (34.34% and 35.20%). Test-retest results ranged from 0.67 to 0.92, except for the step width (0.25). Summarizing, it appears that the parameters describing the lateral distance between the feet need further improvement. However, the results of the validity and reliability of the IMU system encourage its validation in clinical settings as well as further research.
3D joint kinematics can provide important information about the quality of movements. Optical motion capture systems (OMC) are considered the gold standard in motion analysis. However, in recent years, inertial measurement units (IMU) have become a promising alternative. The aim of this study was to validate IMU-based 3D joint kinematics of the lower extremities during different movements. Twenty-eight healthy subjects participated in this study. They performed bilateral squats (SQ), single-leg squats (SLS) and countermovement jumps (CMJ). The IMU kinematics was calculated using a recently-described sensor-fusion algorithm. A marker based OMC system served as a reference. Only the technical error based on algorithm performance was considered, incorporating OMC data for the calibration, initialization, and a biomechanical model. To evaluate the validity of IMU-based 3D joint kinematics, root mean squared error (RMSE), range of motion error (ROME), Bland-Altman (BA) analysis as well as the coefficient of multiple correlation (CMC) were calculated. The evaluation was twofold. First, the IMU data was compared to OMC data based on marker clusters; and, second based on skin markers attached to anatomical landmarks. The first evaluation revealed means for RMSE and ROME for all joints and tasks below 3°. The more dynamic task, CMJ, revealed error measures approximately 1° higher than the remaining tasks. Mean CMC values ranged from 0.77 to 1 over all joint angles and all tasks. The second evaluation showed an increase in the RMSE of 2.28°– 2.58° on average for all joints and tasks. Hip flexion revealed the highest average RMSE in all tasks (4.87°– 8.27°). The present study revealed a valid IMU-based approach for the measurement of 3D joint kinematics in functional movements of varying demands. The high validity of the results encourages further development and the extension of the present approach into clinical settings.
High‐intensity (resistance) exercise (HIT) and whole‐body electromyostimulation (WB‐EMS) are both approaches to realize time‐efficient favorable changes of body composition and strength. The purpose of this study was to determine the effectiveness of WB‐EMS compared with the gold standard reference HIT, for improving body composition and muscle strength in middle‐aged men. Forty‐eight healthy untrained men, 30–50 years old, were randomly allocated to either HIT (2 sessions/week) or a WB‐EMS group (3 sessions/2 weeks) that exercised for 16 weeks. HIT was applied as “single‐set‐to‐failure protocol,” while WB‐EMS was conducted with intermittent stimulation (6 s WB‐EMS, 4 s rest; 85 Hz, 350 ms) over 20 minutes. The main outcome parameters were lean body mass (LBM) as determined via dual‐energy X‐ray absorptiometry and maximum dynamic leg‐extensor strength (isokinetic leg‐press). LBM changes of both groups (HIT 1.25 ± 1.44% versus WB‐EMS 0.93 ± 1.15%) were significant (p = .001); however, no significant group differences were detected (p = .395). Leg‐extensor strength also increased in both groups (HIT 12.7 ± 14.7%, p = .002, versus WB‐EMS 7.3 ± 10.3%, p = .012) with no significant (p = .215) between‐group difference. Corresponding changes were also determined for body fat and back‐extensor strength. Conclusion. In summary, WB‐EMS can be considered as a time‐efficient but pricy option to HIT‐resistance exercise for people aiming at the improvement of general strength and body composition.
Exercise positively affects most risk factors, diseases and disabling conditions of middle to advanced age, however the majority of middle-aged to older people fall short of the exercise doses recommended for positively affecting cardio-metabolic, musculoskeletal and neurophysiological fitness or disabling conditions. Whole-Body Electromyostimulation (WB-EMS) may be a promising exercise technology for people unable or unmotivated to exercise conventionally. However, until recently there has been a dearth of evidence with respect to WB-EMS-induced effects on health-related outcomes. The aim of this systematic review is to summarize the effects, limitations and risks of WB-EMS as a preventive or therapeutic tool for non-athletic adults. Electronic searches in PubMed, Scopus, Web of Science, PsycINFO, Cochrane and Eric were run to identify randomized controlled trials, non-randomized controlled trials, meta-analyses of individual patient data and peer reviewed scientific theses that examined (1) WB-EMS-induced changes of musculoskeletal risk factors and diseases (2) WB-EMS-induced changes of functional capacity and physical fitness (3) WB-EMS-induced changes of cardio-metabolic risk factors and diseases (4) Risk factors of WB-EMS application and adverse effects during WB-EMS interventions. Two researchers independently reviewed articles for eligibility and methodological quality. Twenty-three eligible research articles generated by fourteen research projects were finally included. In summary, thirteen projects were WB-EMS trials and one study was a meta-analysis of individual patient data. WB-EMS significantly improves muscle mass and function while reducing fat mass and low back pain. Although there is some evidence of a positive effect of WB-EMS on cardio-metabolic risk factors, this aspect requires further detailed study. Properly applied and supervised, WB-EMS appears to be a safe training technology. In summary, WB-EMS represents a safe and reasonable option for cohorts unable or unwilling to join conventional exercise programs. However, much like all other types of exercise, WB-EMS does not affect every aspect of physical performance and health.