Michelle Marie Mellenthin

Dr. Michelle Marie Mellenthin

Department of Computer Science and Engineering, Colorado Mesa University, Grand Junction, Colorado, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Michelle Marie MellenthinMichelle Marie Mellenthin
Michelle Marie Mellenthin
JMJennifer L. Mueller
Jennifer L. Mueller
ECErick Dario Leon Bueno de Camargo
Erick Dario Leon Bueno de Camargo
FMFernando Silva de Moura
Fernando Silva de Moura
TSTalles Batista Rattis Santos
Talles Batista Rattis Santos
MAMelody Alsaker
Melody Alsaker
The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.

1 April 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
PMPeter A Muller
Peter A Muller
JMJennifer L. Mueller
Jennifer L. Mueller
Michelle Marie MellenthinMichelle Marie Mellenthin
Michelle Marie Mellenthin
RMRashmi Murthy
Rashmi Murthy
MCMichael Capps
Michael Capps
JHJordana Hoppe
Jordana Hoppe
Objective : Lung function monitoring by spirometry plays a critical role in the clinical care of pediatric cystic fibrosis (CF) patients, but many young children are unable to perform spirometry, and the outputs are often normal even in the presence of lung disease. Measures derived from electrical impedance tomography (EIT) images were studied for their utility as potential surrogates for spirometry in CF patients and to assess response to intravenous antibiotic treatment for acute pulmonary exacerbations (PEx) in a subset of patients. Approach : EIT data were collected on 35 subjects (21 with CF, 14 healthy controls, 8 CF patients pre- and post-treatment for an acute PEx) ages 2 to 20 years during tidal breathing and also concurrently with spirometry on subjects over age 8. EIT-derived measures of FEV1, FVC, and FEV1/FVC were computed globally and regionally from dynamic EIT images. Main results : Global EIT-derived FEV1/FVC showed good correlation with spirometry FEV1/FVC values (r = 0.54, p = 0.01), and were able to distinguish between the groups (p = 0.01). Lung heterogeneity was assessed through the spatial coefficient of variation (CV) of EIT difference images between key time points, and the CVs for EIT-derived FEV1 and FVC showed significant correlation with the CV for tidal breathing (r = 0.47, p = 0.01 and r = 0.50, p = 0.01, respectively). Global EIT-derived FEV1/FVC was better able to distinguish between groups than spirometry FEV1 (F-values 776.5 and 146.3, respectively, p < 0.01.) The same held true for the CVs for EIT-derived FEV1, FVC, and tidal breathing (F-values 215.93, 193.89, 204.57, respectively, p < 0.01). Significance : The strong correlation between the CVs for tidal breathing, FEV1, and FVC, and the statistically significant ability of CV for tidal breathing to distinguish between healthy subjects and CF patients, and between the studied CF disease states suggests that the CV may be useful for measuring the extent and severity of structural lung disease.

1 May 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
JMJennifer L. Mueller
Jennifer L. Mueller
PMPeter Muller
Peter Muller
Michelle Marie MellenthinMichelle Marie Mellenthin
Michelle Marie Mellenthin
RMRashmi Murthy
Rashmi Murthy
MCMichael Capps
Michael Capps
EDEmily DeBoer
Emily DeBoer
Objective : Electrical impedance tomography (EIT) has been shown to be a viable non-invasive, bedside imaging modality to monitor lung function. This paper introduces a method for identifying regions of air trapping from EIT data collected during tidal breathing and breath-holding maneuvers. Approach : Ventilation–perfusion index maps are computed from dynamic EIT images. These maps are then used to identify regions of air trapping in the area of the lung as regions that are poorly ventilated but well perfused throughout the breathing and cardiac cycles. These EIT-identified regions are then compared with independently identified regions of low attenuation, or air trapping, on chest CT. Results of this method are demonstrated in two children with cystic fibrosis and on a healthy control subject. Main results : In both CF children, the EIT-identified regions of air trapping matched the regions indicated from the chest CT. The EIT-based method is only validated with CT scans within 4 cm of the chest cross-section defined by the electrode plane. Significance : The results indicate the potential use of EIT-derived ventilation–perfusion index maps as a non-invasive method for identifying regions of air trapping.

19 April 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PMPeter A. Muller
Peter A. Muller
JMJennifer L. Mueller
Jennifer L. Mueller
Michelle Marie MellenthinMichelle Marie Mellenthin
Michelle Marie Mellenthin
A real-time implementation of Calderón's method for the reconstruction of a 2-D conductivity from electrical impedance tomography data is presented, in which domain-specific modeling is taken into account. This is the first implementation of Calderón's method that accounts for correct modeling of non-symmetric domain boundaries in image reconstruction. The domain-specific Calderón's method is derived and reconstructions from experimental tank data are presented, quantifying the distortion when correct modeling is not included in the reconstruction algorithm. Reconstructions from human subject volunteers are presented, demonstrating the method's effectiveness for imaging changes due to ventilation and perfusion in the human thorax.

1 July 2019 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
Michelle Marie MellenthinMichelle Marie Mellenthin
Michelle Marie Mellenthin
SSSiyeon A. Seong
Siyeon A. Seong
GRGregory S. Roy
Gregory S. Roy
EBElizabeth Bartolák-Suki
Elizabeth Bartolák-Suki
KHKatharine L. Hamlington
Katharine L. Hamlington
BSBradford Smith
Bradford Smith
Identifying safe ventilation patterns for patients with acute respiratory distress syndrome remains challenging because of the delicate balance between gas exchange and selection of ventilator settings to prevent further ventilator-induced lung injury (VILI). Accordingly, this work seeks to link ventilator settings to graded levels of VILI to identify injury cost functions that predict injury by using a computational model to process pressures and flows measured at the airway opening. Pressure-volume loops were acquired over the course of ~2 h of mechanical ventilation in four different groups of BALB/c mice. A cohort of these animals were subjected to an injurious bronchoalveolar lavage before ventilation. The data were analyzed with a single-compartment model that predicts recruitment/derecruitment and tissue distension at each time step in measured pressure-volume loops. We compared several injury cost functions to markers of VILI-induced blood-gas barrier disruption. Of the cost functions considered, we conclude that mechanical power dissipation and strain heterogeneity are the best at distinguishing between graded levels of injury and are good candidates for forecasting the development of VILI. NEW & NOTEWORTHY This work uses a predictive single-compartment model and injury cost functions to assess graded levels of mechanical ventilator-induced lung injury. The most promising measures include strain heterogeneity and mechanical power dissipation.

18 February 2021 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
PDF file
JPJoshua Pertile
Joshua Pertile
BSBradford Smith
Bradford Smith
Michelle Marie MellenthinMichelle Marie Mellenthin
Michelle Marie Mellenthin
JWJennifer Wagner
Jennifer Wagner
EDEmily M. DeBoer
Emily M. DeBoer
DFDaniel S. Fink
Daniel S. Fink
Objectives: Although jet ventilation is frequently used during surgery for airway stenosis, little is known about distal airway pressures during jet ventilation. The objective of the study is to determine how jet pressure, flow rate, and position of the ventilation needle relate to distal airway pressure magnitude and homogeneity.Methods: Two 3D models of the first five generations of the human airway tree were created. One is a duplicate of a human airway from a 15‐year‐old healthy male's computed tomography scan, and the other is an idealized symmetric model of human lung morphometry. Pressure transducers measured fifth‐generation distal airway pressures in both models. A computer‐controlled jet needle positioning system was used to ventilate the lung casts. The effects of jet needle position, jet pressure, and jet flow rate on distal airway pressure and homogeneity were measured.Results: Total entrained jet flow rate was the most reliable predictor of distal airway pressure. Pressure supplied to the jet ventilation needle had a positive linear relationship with distal airway pressure; however, this relationship was dependent on the jet needle flow resistance. As the ventilation needle moved closer to the tracheal wall, ventilation homogeneity decreased. Depth into the trachea was positively correlated with sensitivity of the needle to the tracheal wall.Conclusion: In this model, total entrained jet flow rate is a more robust predictor of distal airway pressure than jet inlet pressure. More homogeneous ventilation was observed in our model with the ventilation needle centered in the proximal region of the trachea.