Mihaela Gherban

Dr. Mihaela Gherban

National Institute for Research and Development in Electrochemistry and Condensed Matter Dr. A. Păunescu Podeanu Street, 144, 300569 Timisoara, Timişoara, Timiş, Romania
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
RVRoxana Vasiliu
Roxana Vasiliu
SPSorin Daniel Porojan
Sorin Daniel Porojan
MGMihaela Gherban
Mihaela Gherban
LPLiliana Porojan
Liliana Porojan
Dental ceramic restorations are widely spread nowadays due to their aesthetics and biocompatibility. In time, the colour and structure of these ceramic materials can be altered by aging processes. How does artificial aging affect the optical and surface roughness of ceramics? This study aims to assess the effect of thermocycling, surface treatments and microstructure upon translucency, opalescence and surface roughness on CAD-CAM and heat-pressed glass-ceramic. Forty-eight samples (1.5 mm thickness) were fabricated from six types of A2 MT ceramic: heat-pressed and milled glass-ceramic (feldspathic, lithium disilicate and zirconia reinforced lithium silicate). The samples were obtained respecting the manufacturer’s instructions. The resulted surfaces (n = 96) were half glazed and half polished. The samples were subjected to thermocycling (10,000 cycles) and roughness values (Ra and Rz), colour coordinates (L*, a*, b*) and microstructural analyses were assessed before and after thermocycling. Translucency (TP) and opalescence (OP) were calculated. Values were statistically analysed using ANOVA test (one way). TP and OP values were significantly different between heat-pressed and milled ceramics before and also after thermocycling (p < 0.001). Surface treatments (glazing and polishing) had a significant effect on TP and OP and surface roughness (p < 0.05). The heat-pressed and milled zirconia reinforced lithium silicate glass-ceramic experienced a loss in TP and OP. Ra and Rz increased for the glazed samples, TP and OP decreased for all the samples after thermocycling. Microstructural analyse revealed that glazed surfaces were more affected by the thermocycling and especially for the zirconia reinforced lithium silicate ceramic. Optical properties and surface roughness of the chosen ceramic materials were affected by thermocycling, surface treatments and microstructural differences. The least affected of the ceramics was the lithium disilicate ceramic heat-pressed polished and glazed.

13 June 2012 in Sensors
Verified
Journal Article
Open access
PDF file
DVDana Vlascici
Dana Vlascici
Eugenia FAGADAR-COSMAEugenia FAGADAR-COSMA
Eugenia FAGADAR-COSMA
IPIuliana Popa
Iuliana Popa
VCVlad Chiriac
Vlad Chiriac
MGMayte Gil-Agusti
Mayte Gil-Agusti
Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl- and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10−7–1 × 10−1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples.

27 March 2009 in Molecules
Verified
Journal Article
Open access
PDF file
Eugenia FAGADAR-COSMAEugenia FAGADAR-COSMA
Eugenia FAGADAR-COSMA
MMMarius Constantin Mirica
Marius Constantin Mirica
IBIonel Balcu
Ionel Balcu
CBCarmen Bucovicean
Carmen Bucovicean
CCCarmen Cretu
Carmen Cretu
GFGheorghe Fagadar-Cosma
Gheorghe Fagadar-Cosma
The present work is concerned with the manganese complexes of 5,10,15,20-tetraphenylporphyrin and of 5,10,15,20-tetra(3-hydroxyphenyl)porphyrin, which were prepared by metallation of the corresponding porphyrin ligands, and the study of their spectroscopic and photophysical behavior under strongly acidic and alkaline conditions. The second objective was to obtain and study some new hybrid materials, with special optoelectronic and surface properties, by impregnation of silica gels obtained by one step acid and by two steps acid-base catalysis with these Mn-porphyrins. The resulting nanomaterials exhibited interesting bathochromic and hyperchromic effects of their second band in the emission spectra in comparison with the Mn-porphyrins and also they have distinct orientation of the aggregates on surfaces, as shown by AFM images, making them useful for applications in medicine, formulation of sensors and for environmental-friendly catalysts for photodegradation of organic compounds.

3 August 2020 in Polymers
Verified
Journal Article
Open access
PDF file
LPLiliana Porojan
Liliana Porojan
RVRoxana Vasiliu
Roxana Vasiliu
SPSorin-Daniel Porojan
Sorin-Daniel Porojan
MGMihaela Gherban
Mihaela Gherban
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography of different thermoplastic materials related to staining beverages and cleaning agents. (2) Methods: Thermoplastic polyethylene terephthalate glycol (PET-G) material specimens were selected for the study: S (Duran, Scheu-Dental GmbH, Iserlohn, Germany), D (Biolon, Dreve Dentamid GmbH, Unna, Germany), and B (Crystal, Bio Art Dental Equipment, Sao Carlos, Brazil). Four different media were involved for immersion: coffee (C) and black tea (T) at 55 °C, Coca-Cola (K) at 5 °C, and distilled water (W) at 22 °C. As for cleaning, chemical options and mechanical brushing were selected (P-powder, T-tablets, and X-brushing). Color changes, and mean surface roughness were measured at 24 h, 48 h, and after 7 days. Statistical analysis was performed. After the testing period, atomic force microscopy (AFM) analyses and SEM images were registered in order to characterize the surface topography. (3) Results: Quantitative color change evaluations revealed a slight change in color after 24 h and an extremely marked change after 48 h, respective 7 days. Mean roughness values are kept below the clinically acceptable limit of 0.20 µm for all samples. Related to mean nanoroughness values Sa, and 3D evaluations of the surface quality, Biolon samples have demonstrated the most constant behavior, while Crystal samples are visibly influenced by water immersion. Related to the cleaning method, the topography of Duran samples was influenced by mechanical brushing. (4) Conclusions: Nanoscale investigations provided high accuracy and more realistic surface quality examinations of the examined samples compared to profilometry. Both SEM and AFM should be used for a more detailed description of the surface topography.

25 August 2008 in Sensors
Verified
Journal Article
Open access
PDF file
DVDana Vlascici
Dana Vlascici
Eugenia FAGADAR-COSMAEugenia FAGADAR-COSMA
Eugenia FAGADAR-COSMA
EPElena Maria Pica
Elena Maria Pica
VCViorica Cosma
Viorica Cosma
OBOtilia Bizerea
Otilia Bizerea
LOLiliana Olenic
Liliana Olenic
Two functionalized porphyrins: 5,10,15,20-tetrakis(3,4-dimethoxyphenyl) porphyrin (A) and 5,10,15,20-tetrakis(3-hydroxyphenyl)porphyrin (B) obtained and characterized by us were used as ionophores (I) for preparing PVC-based membrane sensors selective to Ag+, Pb2+ and Cu2+. The membranes were prepared using three different plasticizers: (bis(2-ethylhexyl)sebacate (DOS), dioctylphtalate (DOP), o-nitrophenyl octyl ether (NPOE) and potassium tetrakis(4-chlorophenyl)borate (KTClPB) as additive. The functional parameters (linear concentration range, slope and selectivity) of the sensors with membrane composition: (I:PVC:KTClPB:Plasticizer) in different ratios were investigated. The best results were obtained for the membranes in the ratio I:PVC:KTClPB:Plasticizer 10:165:5:330. The influence of pH on the sensors response was studied. The sensors were used for a period of four months and their utility has been tested on synthetic and real samples.

1 December 2016 in Applied Surface Science
Verified
Journal Article
Closed access
ISI. Sebarchievici
I. Sebarchievici
BTBogdan Taranu
Bogdan Taranu
MGMihaela Gherban
Mihaela Gherban
SRS.F. Rus
S.F. Rus
Eugenia FAGADAR-COSMAEugenia FAGADAR-COSMA
Eugenia FAGADAR-COSMA