Energy harvesting technologies have been explored by researchers for more than two decades as an alternative to conventional power sources (e.g. batteries) for small-sized and low-power electronic devices. The limited life-time and necessity for periodic recharging or replacement of batteries has been a consistent issue in portable, remote, and implantable devices. Ambient energy can usually be found in the form of solar energy, thermal energy, and vibration energy. Amongst these energy sources, vibration energy presents a persistent presence in nature and manmade structures. Various materials and transduction mechanisms have the ability to convert vibratory energy to useful electrical energy, such as piezoelectric, electromagnetic, and electrostatic generators. Piezoelectric transducers, with their inherent electromechanical coupling and high power density compared to electromagnetic and electrostatic transducers, have been widely explored to generate power from vibration energy sources. A topical review of piezoelectric energy harvesting methods was carried out and published in this journal by the authors in 2007. Since 2007, countless researchers have introduced novel materials, transduction mechanisms, electrical circuits, and analytical models to improve various aspects of piezoelectric energy harvesting devices. Additionally, many researchers have also reported novel applications of piezoelectric energy harvesting technology in the past decade. While the body of literature in the field of piezoelectric energy harvesting has grown significantly since 2007, this paper presents an update to the authors’ previous review paper by summarizing the notable developments in the field of piezoelectric energy harvesting through the past decade.
15 January 2018 in IEEE/ASME Transactions on Mechatronics
The knee replacement is one of the most common orthopedic surgical interventions in the United States; however, recent studies have shown up to 20% of patients are dissatisfied with the outcome. One of the key issues to improving these operations is a better understanding of the ligamentous balance during and after surgery. The goal of this paper is to investigate the feasibility of embedding piezoelectric transducers in the polyethylene bearing of a total knee replacement to act as self-powered sensors to aid in the alignment and balance of the knee replacement by providing intra- and postoperative feedback to the surgeon. A model consisting of a polyethylene disc with a single embedded piezoelectric ceramic transducer is investigated as a basis for future work. A modeling framework is developed including a biomechanical model of the knee joint, a finite element model of the knee bearing with encapsulated transducer, and an electromechanical model of the piezoelectric transducer. Model predictions show that a peak voltage of 2.3 V with a load resistance of 1.01 MΩ can be obtained from a single embedded piezoelectric stack, and an average power of 12 μW can be obtained from a knee bearing with four embedded piezoelectric transducers. Uniaxial compression testing is also performed on a fabricated sample for model validation. The results found in this paper show promising potential of embedded piezoelectric transducers to be utilized for autonomous self-powered in vivo knee implant force sensors.
Recent developments in the field of orthopedic materials and procedures have made the total knee replacement an option for people who suffer from knee diseases and injuries. One of the ongoing debates in this area involves the correlation of postoperative joint functionality to intraoperative alignment. Due to a lack of in vivo data from the knee joint after surgery, the establishment of a well-quantified alignment method is hindered. In order to obtain information about knee function after the operation, the design of a self-powered instrumented knee implant is proposed in this study. The design consists of a total knee replacement bearing equipped with four piezoelectric transducers distributed in the medial and lateral compartments. The piezoelectric transducers are utilized to measure the total axial force applied on the tibial bearing through the femoral component of the joint, as well as to track the movement in the center of pressure (CoP). In addition, the generated voltage from the piezoelectrics can be harvested and stored to power embedded electronics for further signal conditioning and data transmission purposes. Initially, finite element analysis is performed on the knee bearing to select the best location of the transducers with regards to sensing the total force and location of the CoP. A series of experimental tests are then performed on a fabricated prototype which aim to investigate the sensing and energy harvesting performance of the device. Piezoelectric force and center of pressure measurements are compared to actual experimental quantities for twelve different relative positions of the femoral component and bearing of the knee implant in order to evaluate the performance of the sensing system. The output voltage of the piezoelectric transducers is measured across a load resistance to determine the optimum extractable power, and then rectified and stored in a capacitor to evaluate the realistic energy harvesting ability of the system. The results show only a small level of error in sensing the force and the location of the CoP. Additionally, a maximum power of 269.1 μ W is achieved with a 175 kΩ optimal resistive load, and a 4.9 V constant voltage is stored in a 3.3 mF capacitor after 3333 loading cycles. The sensing and energy harvesting results present the promising potential of this system to be used as an integrated self-powered instrumented knee implant.
19 January 2017 in Journal of Intelligent Material Systems and Structures
Superelastic shape memory alloys dissipate significant amount of energy since they recover large transformation strains upon mechanical unloading. Due to their dissipation properties, shape memory alloys can be effectively employed as dampers. Design, simulation, and fabrication of a newly developed superelastic shape memory alloy damper are discussed in this article. To enhance the stroke and dissipation capacity of the proposed damper, a system is implemented which operates more efficiently than a single shape memory alloy wire. Although shape memory alloy wires can only undergo tension, the new system enables the damper to be loaded in both tension and compression. Two damping groups are employed in this mechanism: one of which is activated during tension and the other is activated during compression of the damper. Each damping group consists of two shape memory alloy wires acting in the opposite directions to increase the damping capacity of the system. The mechanical responses of the individual components as well as the assembled damper are simulated. The predicted performance of the damper is then validated through tension/compression tests on the fabricated sample. Numerical and experimental force–displacement curves are also shown to be in a good agreement. The effect of different parameters on damping ratio and dissipated energy of the presented damper is investigated.
13 October 2020 in Journal of Vibration and Acoustics
In this study, we propose a new mounting method to improve accelerometer sensing performance in the 50 Hz–10 kHz frequency band for knee sound measurement. The proposed method includes a thin double-sided adhesive tape for mounting and a 3D-printed custom-designed backing prototype. In our mechanical setup with an electrodynamic shaker, the measurements showed a 13 dB increase in the accelerometer's sensing performance in the 1–10 kHz frequency band when it is mounted with the craft tape under 2 N backing force applied through low-friction tape. As a proof-of-concept study, knee sounds of healthy subjects (n = 10) were recorded. When the backing force was applied, we observed statistically significant (p < 0.01) incremental changes in spectral centroid, spectral roll-off frequencies, and high-frequency (1–10 kHz) root-mean-square (RMS) acceleration, while low-frequency (50 Hz–1 kHz) RMS acceleration remained unchanged. The mean spectral centroid and spectral roll-off frequencies increased from 0.8 kHz and 4.15 kHz to 1.35 kHz and 5.9 kHz, respectively. The mean high-frequency acceleration increased from 0.45 mgRMS to 0.9 mgRMS with backing. We showed that the backing force improves the sensing performance of the accelerometer when mounted with the craft tape and the proposed backing prototype. This new method has the potential to be implemented in today's wearable systems to improve the sensing performance of accelerometers in knee sound measurements.