Vahid Moosabeiki

Dr. Vahid Moosabeiki

TU Delft, Delft, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
Mohammad J. MirzaaliMohammad J. Mirzaali
Mohammad J. Mirzaali
Vahid MoosabeikiVahid Moosabeiki
Vahid Moosabeiki
SRSeyed Mohammad Rajaai
Seyed Mohammad Rajaai
Jie ZhouJie Zhou
Jie Zhou
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
Additive manufacturing (AM, also known as 3D printing) is an advanced manufacturing technique that has enabled progress in the design and fabrication of customised or patient-specific (meta-)biomaterials and biomedical devices (e.g., implants, prosthetics, and orthotics) with complex internal microstructures and tuneable properties. In the past few decades, several design guidelines have been proposed for creating porous lattice structures, particularly for biomedical applications. Meanwhile, the capabilities of AM to fabricate a wide range of biomaterials, including metals and their alloys, polymers, and ceramics, have been exploited, offering unprecedented benefits to medical professionals and patients alike. In this review article, we provide an overview of the design principles that have been developed and used for the AM of biomaterials as well as those dealing with three major categories of biomaterials, i.e., metals (and their alloys), polymers, and ceramics. The design strategies can be categorised as: library-based design, topology optimisation, bio-inspired design, and meta-biomaterials. Recent developments related to the biomedical applications and fabrication methods of AM aimed at enhancing the quality of final 3D-printed biomaterials and improving their physical, mechanical, and biological characteristics are also highlighted. Finally, examples of 3D-printed biomaterials with tuned properties and functionalities are presented.

12 December 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
MSM. C. Saldívar
M. C. Saldívar
ETE. Tay
E. Tay
AIA. Isaakidou
A. Isaakidou
Vahid MoosabeikiVahid Moosabeiki
Vahid Moosabeiki
LFL. E. Fratila-Apachitei
L. E. Fratila-Apachitei
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
Durable interfacing of hard and soft materials is a major design challenge caused by the ensuing stress concentrations. In nature, soft-hard interfaces exhibit remarkable mechanical performance, with failures rarely happening at the interface. Here, we mimic the strategies observed in nature to design efficient soft-hard interfaces. We base our geometrical designs on triply periodic minimal surfaces (i.e., Octo, Diamond, and Gyroid), collagen-like triple helices, and randomly distributed particles. A combination of computational simulations and experimental techniques, including uniaxial tensile and quad-lap shear tests, are used to characterize the mechanical performance of the interfaces. Our analyses suggest that smooth interdigitated connections, compliant gradient transitions, and either decreasing or constraining strain concentrations lead to simultaneously strong and tough interfaces. We generate additional interfaces where the abovementioned toughening mechanisms work synergistically to create soft-hard interfaces with strengths approaching the upper achievable limit and enhancing toughness values by 50%, as compared to the control group.

30 September 2016 in Journal of Central South University
Verified
Journal Article
Closed access
PDF file
Vahid MoosabeikiVahid Moosabeiki
Vahid Moosabeiki
SGSaeede Ghorbanpour
Saeede Ghorbanpour
GAGhasem Azimi
Ghasem Azimi

26 May 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
AKA. van Kootwijk
A. van Kootwijk
Vahid MoosabeikiVahid Moosabeiki
Vahid Moosabeiki
MSM. Cruz Saldivar
M. Cruz Saldivar
HPH. Pahlavani
H. Pahlavani
MLM.A. Leeflang
M.A. Leeflang
AZA.A. Zadpoor
A.A. Zadpoor
The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti-6Al-4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p < 0.05) in the mean stiffness, mean ultimate load, or mean ultimate displacement were detected between the LA- and TO-implant groups. No implant failures were observed during quasi-static or cyclic testing under masticatory loads that were substantially higher (>1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome.

7 July 2022 in Communications Materials
Verified
Journal Article
Open access
PDF file
TMTeunis van Manen
Teunis van Manen
Vahid MoosabeikiVahid Moosabeiki
Vahid Moosabeiki
MSMauricio Cruz Saldívar
Mauricio Cruz Saldívar
MMMohammad J. Mirzaali
Mohammad J. Mirzaali
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
4D printing of flat sheets that self-fold into architected 3D structures is a powerful origami-inspired approach for the fabrication of multi-functional devices and metamaterials. However, the opposite stiffness requirements for the folding process and the subsequent loadbearing of 3D structures impose an intrinsic limitation in designing self-folding metamaterials: while a low stiffness is required for the successful completion of the self-folding step, a high stiffness is needed for utilizing the folded structure as a load-bearing mechanical metamaterial. Here, we present a nonlinear analytical model of self-folding bilayer constructs composed of an active and passive layer. This finite-deformation theoretical model predicts the curvature of activated bilayers, establishes their stability limits, and estimates the stiffness of folded bilayers, yielding the theoretical stiffness limits of self-folding bilayers. We use our model to identify the optimal combinations of geometrical and mechanical properties that result in the highest possible stiffness of folded constructs. We then compare the predictions of our analytical model with computational results, and validate our theory with experimental realizations of 4D printed structures. Finally, we evaluate the theoretical stiffness limits of bilayer constructs made using the most common types of stimuli-responsive materials. Our analysis shows that a maximum effective modulus of ≈ 1.5 GPa can be achieved using the currently available shape-memory polymers.

21 February 2024 in Acta Biomaterialia
Verified
Journal Article
Open access
NPNiko Eka Putra
Niko Eka Putra
Vahid MoosabeikiVahid Moosabeiki
Vahid Moosabeiki
MLMarius A. Leeflang
Marius A. Leeflang
Jie ZhouJie Zhou
Jie Zhou
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor
Additively manufactured (AM) biodegradable porous iron-manganese (FeMn) alloys have recently been developed as promising bone-substituting biomaterials. However, their corrosion fatigue behavior has not yet been studied. Here, we present the first study on the corrosion fatigue behavior of an extrusion-based AM porous Fe35Mn alloy under cyclic loading in air and in the revised simulated body fluid (r-SBF), including the fatigue crack morphology and distribution in the porous structure. We hypothesized that the fatigue behavior of the architected AM Fe35Mn alloy would be strongly affected by the simultaneous biodegradation process. We defined the endurance limit as the maximum stress at which the scaffolds could undergo 3 million loading cycles without failure. The endurance limit of the scaffolds was determined to be 90% of their yield strength in air, but only 60% in r-SBF. No notable crack formation in the specimens tested in air was observed even after loading up to 90% of their yield strength. As for the specimens tested in r-SBF, however, cracks formed in the specimens subjected to loads exceeding 60% of their yield strength appeared to initiate on the periphery and propagate toward the internal struts. Altogether, the results show that the extrusion-based AM porous Fe35Mn alloy is capable of tolerating up to 60% of its yield strength for up to 3 million cycles, which corresponds to 1.5 years of use of load-bearing implants subjected to repetitive gait cycles. The fatigue performance of the alloy thus further enhances its potential for trabecular bone substitution subjected to cyclic compressive loading. STATEMENT OF SIGNIFICANCE: Fatigue behavior of extrusion-based AM porous Fe35Mn alloy scaffolds in air and revised simulated body fluid was studied. The Fe35Mn alloy scaffolds endured 90% of their yield strength for up to 3×106 loading cycles in air. Moreover, the scaffolds tolerated 3×106 loading cycles at 60% of their yield strength in revised simulated body fluid. The Fe35Mn alloy scaffolds exhibited a capacity of withstanding 1.5-year physiological loading when used as bone implants.