Mrigank Maharana

Mr. Mrigank Maharana

Bioengineering, The University of Texas at Dallas, Richardson, Texas, USA
+1

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
MKMahasty Khajehzadeh
Mahasty Khajehzadeh
CNChristopher K. Nguyen
Christopher K. Nguyen
Mrigank MaharanaMrigank Maharana
Mrigank Maharana
SPShriya Peddapuram
Shriya Peddapuram
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
SCStuart Cogan
Stuart Cogan
Insertion of microelectrode arrays (MEAs) into brain tissue remains a mechanical challenge, especially for long, thin probes designed to access deep structures. This study investigates the mechanical properties of 5 mm long amorphous silicon carbide (a-SiC) probes with different geometries and the effect of vibration-assisted insertion on penetration into rat brain. Methods: Two planar a-SiC probe designs were fabricated with identical lengths and thicknesses but differing width geometries: one with a uniform width (175 µm) and the other with a tapered shape (tapering from 175 to 75 µm). Critical buckling forces (FCs) were estimated by finite element modeling (FEM) and validated experimentally. Insertion mechanics were assessed in a brain mimic of 1.2% agarose gel at varying insertion speeds (20–1000 µm/s) and in vivo by implantation in rat cortex. Insertion metrics included penetration force (FP), cortical dimpling depth (Dd), maximum insertion force (Fmax), and success rate of insertion, all evaluated with and without vibrational assistance. Results: The tapered design exhibited lower penetration force and higher insertion success compared to the uniform-width probe, despite having a lower critical buckling force. An optimal insertion rate of 100 µm/s was identified, balancing insertion time with low Fmax and high insertion success across designs. Higher FP and Dd with a lower success rate were observed for uniform probes compared with tapered probes in rat brain. Vibration-assisted insertion was then investigated with tapered probes. Applying vibration significantly reduced FP, whereas Dd and Fmax remained unchanged. Notably, in 40% of actuated insertions in rat, no detectable FP peak was observed, suggesting unimpeded pial penetration. Conclusions: A tapered probe geometry and vibration-assisted insertion can reduce Fmax and FP while enhancing the insertion success rate for probe penetration in rat brain. These strategies are generally applicable to long-shank MEA insertions in brain and may inform design and insertion strategies.