Nadia Fareeda Muhammad Gowdh

Dr. Nadia Fareeda Muhammad Gowdh

University of Malaya
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Prabal Datta BaruaPrabal Datta Barua
Prabal Datta Barua
Nadia Fareeda Muhammad GowdhNadia Fareeda Muhammad Gowdh
Nadia Fareeda Muhammad Gowdh
KRKartini Rahmat
Kartini Rahmat
NRNORLISAH MOHD RAMLI
NORLISAH MOHD RAMLI
WNWei Lin Ng
Wei Lin Ng
U Rajendra AcharyaU Rajendra Acharya
U Rajendra Acharya
COVID-19 and pneumonia detection using medical images is a topic of immense interest in medical and healthcare research. Various advanced medical imaging and machine learning techniques have been presented to detect these respiratory disorders accurately. In this work, we have proposed a novel COVID-19 detection system using an exemplar and hybrid fused deep feature generator with X-ray images. The proposed Exemplar COVID-19FclNet9 comprises three basic steps: exemplar deep feature generation, iterative feature selection and classification. The novelty of this work is the feature extraction using three pre-trained convolutional neural networks (CNNs) in the presented feature extraction phase. The common aspects of these pre-trained CNNs are that they have three fully connected layers, and these networks are AlexNet, VGG16 and VGG19. The fully connected layer of these networks is used to generate deep features using an exemplar structure, and a nine-feature generation method is obtained. The loss values of these feature extractors are computed, and the best three extractors are selected. The features of the top three fully connected features are merged. An iterative selector is used to select the most informative features. The chosen features are classified using a support vector machine (SVM) classifier. The proposed COVID-19FclNet9 applied nine deep feature extraction methods by using three deep networks together. The most appropriate deep feature generation model selection and iterative feature selection have been employed to utilise their advantages together. By using these techniques, the image classification ability of the used three deep networks has been improved. The presented model is developed using four X-ray image corpora (DB1, DB2, DB3 and DB4) with two, three and four classes. The proposed Exemplar COVID-19FclNet9 achieved a classification accuracy of 97.60%, 89.96%, 98.84% and 99.64% using the SVM classifier with 10-fold cross-validation for four datasets, respectively. Our developed Exemplar COVID-19FclNet9 model has achieved high classification accuracy for all four databases and may be deployed for clinical application.

11 March 2025 in IEEE Access
Verified
Journal Article
Open access
MIMahesh Anil Inamdar
Mahesh Anil Inamdar
AGAnjan Gudigar
Anjan Gudigar
RURaghavendra U.
Raghavendra U.
Massimo SalviMassimo Salvi
Massimo Salvi
RARaja Rizal Azman
Raja Rizal Azman
UAU. Rajendra Acharya
U. Rajendra Acharya
One of the main causes of death and permanent disability is ischemic stroke, for which prompt and precise diagnosis is essential to successful treatment. This study introduces a novel dual-stream deep learning framework for ischemic stroke classification using Computed Tomography (CT) images, specifically addressing challenges in accuracy, computational efficiency, and clinical interpretability. Three significant innovations are included in the suggested architecture: (1) a hybrid Dual Attention Mechanism that combines Dynamic Routing and Cross-Attention for improved region-specific feature discrimination; (2) a Multi-Scale Feature Extraction Module with parallel convolutional pathways that captures both contextual and fine-grained features; and (3) an Adaptive Random Vector Functional Link layer that significantly reduces training time while maintaining high classification performance. When tested on a single-center dataset, the model achieves state-of-the-art classification accuracy of 98.83% across normal, acute and chronic stroke categories. We demonstrate the strong generalization capabilities of the proposed framework by achieving 92.42% accuracy on a diverse, multi-center dataset of 7,842 CT images. The integration of explainable Artificial Intelligence tools improves clinical trustworthiness by offering clear insight into the model’s decision-making process. These outcomes demonstrate the model’s potential for use in actual clinical settings for quick and accurate stroke diagnosis, along with its interpretability and computational efficiency.

11 January 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KNKenta Ninomiya
Kenta Ninomiya
HAHidetaka Arimura
Hidetaka Arimura
WCWai Yee Chan
Wai Yee Chan
KTKentaro Tanaka
Kentaro Tanaka
SMShinichi Mizuno
Shinichi Mizuno
KNKwan Hoong Ng
Kwan Hoong Ng
Objectives: To propose a novel robust radiogenomics approach to the identification of epidermal growth factor receptor (EGFR) mutations among patients with non-small cell lung cancer (NSCLC) using Betti numbers (BNs). Materials and methods: Contrast enhanced computed tomography (CT) images of 194 multi-racial NSCLC patients (79 EGFR mutants and 115 wildtypes) were collected from three different countries using 5 manufacturers’ scanners with a variety of scanning parameters. Ninety-nine cases obtained from the University of Malaya Medical Centre (UMMC) in Malaysia were used for training and validation procedures. Forty-one cases collected from the Kyushu University Hospital (KUH) in Japan and fifty-four cases obtained from The Cancer Imaging Archive (TCIA) in America were used for a test procedure. Radiomic features were obtained from BN maps, which represent topologically invariant heterogeneous characteristics of lung cancer on CT images, by applying histogram- and texture-based feature computations. A BN-based signature was determined using support vector machine (SVM) models with the best combination of features that maximized a robustness index (RI) which defined a higher total area under receiver operating characteristics curves (AUCs) and lower difference of AUCs between the training and the validation. The SVM model was built using the signature and optimized in a five-fold cross validation. The BN-based model was compared to conventional original image (OI)- and wavelet-decomposition (WD)-based models with respect to the RI between the validation and the test. Results: The BN-based model showed a higher RI of 1.51 compared with the models based on the OI (RI: 1.33) and the WD (RI: 1.29). Conclusion: The proposed model showed higher robustness than the conventional models in the identification of EGFR mutations among NSCLC patients. The results suggested the robustness of the BN-based approach against variations in image scanner/scanning parameters.

1 June 2021 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
LYLilian Poh Poh Yap
Lilian Poh Poh Yap
JWJeannie Hsiu Ding Wong
Jeannie Hsiu Ding Wong
Nadia Fareeda Muhammad GowdhNadia Fareeda Muhammad Gowdh
Nadia Fareeda Muhammad Gowdh
WNWei Lin Ng
Wei Lin Ng
ECEric Chung
Eric Chung
FSFadhli Mohamed Sani
Fadhli Mohamed Sani

1 June 2021 in Current Medical Imaging
Verified
Journal Article
Closed access
PDF file
WCWai Yee Chan
Wai Yee Chan
MHMarlina Tanty Ramli Hamid
Marlina Tanty Ramli Hamid
Nadia Fareeda Muhammad GowdhNadia Fareeda Muhammad Gowdh
Nadia Fareeda Muhammad Gowdh
KRKartini Rahmat
Kartini Rahmat
NYNur Adura Yaakup
Nur Adura Yaakup
CCChee Shee Chai
Chee Shee Chai
Background: Coronavirus disease 2019 (COVID-19) is highly contagious and has claimed more than one million lives, besides causing hardship and disruptions. The Fleischner Society has recommended chest X-ray (CXR) in detecting cases at high risk of disease progression, for triaging suspected patients with moderate-to-severe illness, and for eliminating false negatives in areas with high pre-test probability or limited resources. Although CXR is less sensitive than real-- time reverse transcription-polymerase chain reaction (RT-PCR) in detecting mild COVID-19, it is nevertheless useful because of equipment portability, low cost and practicality in serial assessments of disease progression among hospitalized patients. Objective: This study aims to review the typical and relatively atypical CXR manifestations of COVID-19 pneumonia in a tertiary care hospital. Methods: The CXRs of 136 COVID-19 patients confirmed through real-time RT-PCR from March to May 2020 were reviewed. Literature search was performed using PubMed. Results: A total of 54 patients had abnormal CXR whilst the others were normal. Typical CXR findings included pulmonary consolidation or ground-glass opacities in a multifocal, bilateral peripheral or lower zone distribution, whereas atypical CXR features comprised cavitation and pleural effusion. Conclusion: Typical findings of COVID-19 infection in chest computed tomography studies can also be seen in CXR. The presence of atypical features is associated with worse disease outcome. Recognition of these features on CXR will improve accuracy and speed of diagnosing COVID-19 patients.

13 April 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
KNKenta Ninomiya
Kenta Ninomiya
HAHidetaka Arimura
Hidetaka Arimura
KTKentaro Tanaka
Kentaro Tanaka
WCWai Yee Chan
Wai Yee Chan
YKYutaro Kabata
Yutaro Kabata
KNKwan Hoong Ng
Kwan Hoong Ng