Nikolai Ushakov

Dr. Nikolai Ushakov

Peter the Great Saint Petersburg Polytechnic University
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2015 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Leonid LiokumovichLeonid Liokumovich
Leonid Liokumovich
Nikolai UshakovNikolai Ushakov
Nikolai Ushakov
OKOleg Kotov
Oleg Kotov
MBMikhail Bisyarin
Mikhail Bisyarin
AHArthur H. Hartog
Arthur H. Hartog
The paper develops a statistical model for the signals received in phase-sensitive optical time domain reflectometry (OTDR) probed by highly coherent sources. The backscattering process is modelled by a set of discrete scatterers with properly chosen parameters. Explicit equations for calculating the amplitude and the phase of the backscattered signal are obtained. The developed model predicts spectral and autocorrelation characteristics of the amplitude signals that are validated by experimental results. Characteristics of the phase signals, practicable for studying the sensing applications of the OTDR system, are presented and studied as well, demonstrating good correspondence with experiment. A more detailed modelling of distributed vibration sensing systems and their response to disturbances along an optical fiber will be possible as an extension of the developed formalism.

27 December 2017 in Geophysical Prospecting
Verified
Journal Article
Closed access
PDF file
AHA.H. Hartog
A.H. Hartog
Leonid LiokumovichLeonid Liokumovich
Leonid Liokumovich
Nikolai UshakovNikolai Ushakov
Nikolai Ushakov
OKOleg Kotov
Oleg Kotov
TDT. Dean
T. Dean
FEF.V. Englich
F.V. Englich

25 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Nikolai UshakovNikolai Ushakov
Nikolai Ushakov
AMAleksandr Markvart
Aleksandr Markvart
Leonid LiokumovichLeonid Liokumovich
Leonid Liokumovich
The paper presents an approach to noninvasively measure pulse wave delay and velocity by means of two multiplexed fiber-optic Fabry-Perot interferometric sensors interrogated by means of spectral interferometry. The pulse wave signals were measured with 1 kHz sampling rate. The obtained optical path difference resolutions are on the order of tens picometers, which allowed the pulse wave signal features as small as 100 pm to be clearly observed in the demodulated waveforms. The pulse wave velocity between different arteries was measured, demonstrating good agreement with the known data, where applicable. The paper also presents a mathematical model based on Cramer-Rao approach, describing the fundamental resolution limits of the pulse wave delay measurement. The derived mathematical model is not limited to fiber-optic pulse wave sensors and can be used for estimating the performance of other systems, such as photoplethysmographic and ultrasound. The reported work paves the way to development of novel all-optical non-invasive systems for medical diagnostics and vital signs monitoring, including portable devices.

14 February 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
CYChengwei Yang
Chengwei Yang
ZWZhuo Wang
Zhuo Wang
KXKun Xiao
Kun Xiao
Nikolai UshakovNikolai Ushakov
Nikolai Ushakov
Santosh KumarSantosh Kumar
Santosh Kumar
RMRui Min
Rui Min
The increasing demand for individualized health monitoring and diagnostics has prompted considerable research into the integration of portable optical fiber biosensors integrated with smartphones. By capitalizing on the benefits offered by optical fibers, these biosensors enable qualitative and quantitative biosensing across a wide range of applications. The integration of these sensors with smartphones, which possess advanced computational power and versatile sensing capabilities, addresses the increasing need for portable and rapid sensing solutions. This extensive evaluation thoroughly examines the domain of optical fiber biosensors in conjunction with smartphones, including hardware complexities, sensing approaches, and integration methods. Additionally, it explores a wide range of applications, including physiological and chemical biosensing. Furthermore, the review provides an analysis of the challenges that have been identified in this rapidly evolving area of research and concludes with relevant suggestions for the progression of the field.

4 August 2014 in Applied Optics
Verified
Journal Article
Closed access
PDF file
Nikolai UshakovNikolai Ushakov
Nikolai Ushakov
Leonid LiokumovichLeonid Liokumovich
Leonid Liokumovich
The factors limiting the resolution of displacement sensors based on the extrinsic Fabry–Perot interferometer were studied. An analytical model giving the dependency of extrinsic Fabry–Perot interferometric (EFPI) resolution on the parameters of an optical setup and a sensor interrogator was developed. The proposed model enables one to either estimate the limit of possible resolution achievable with a given setup, or derive the requirements for optical elements and/or a sensor interrogator necessary for attaining the desired sensor resolution. An experiment supporting the analytical derivations was performed, demonstrating a large dynamic measurement range (with cavity length from tens of microns to 5 mm), a high baseline resolution (from 14 pm), and good agreement with the model.

25 April 2021 in Photonics
Verified
Journal Article
Open access
PDF file
Nikolai UshakovNikolai Ushakov
Nikolai Ushakov
AMAleksandr Markvart
Aleksandr Markvart
DKDaria Kulik
Daria Kulik
Leonid LiokumovichLeonid Liokumovich
Leonid Liokumovich
Pulse wave (PW) measurement is a highly prominent technique, used in biomedical diagnostics. Development of novel PW sensors with increased accuracy and reduced susceptibility to motion artifacts will pave the way to more advanced healthcare technologies. This paper reports on a comparison of performance of fiber optic pulse wave sensors, based on Fabry–Perot interferometer, fiber Bragg grating, optical coherence tomography (OCT) and singlemode-multimode-singlemode intermodal interferometer. Their performance was tested in terms of signal to noise ratio, repeatability of demodulated signals and suitability of demodulated signals for extraction of information about direct and reflected waves. It was revealed that the OCT approach of PW monitoring provided the best demodulated signal quality and was most robust against motion artifacts. Advantages and drawbacks of all compared PW measurement approaches in terms of practical questions, such as multiplexing capabilities and abilities to be interrogated by portable hardware are discussed.