Nicolas De Angelis

Dr. Nicolas De Angelis

INAF-IAPS, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
NANicolas De Angelis
Nicolas De Angelis
MKMerlin Reynaard Kole
Merlin Reynaard Kole
FCF. Cadoux
F. Cadoux
JHJ. Hulsman
J. Hulsman
TKT. Kowalski
T. Kowalski
XWX. Wu
X. Wu

25 October 2022 in Experimental Astronomy
Verified
Journal Article
Open access
PDF file
SMSlawomir Mianowski
Slawomir Mianowski
NANicolas De Angelis
Nicolas De Angelis
JHJohannes Hulsman
Johannes Hulsman
MKMerlin Reynaard Kole
Merlin Reynaard Kole
TKTomasz Kowalski
Tomasz Kowalski
XWXin Wu
Xin Wu
POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China. The instrument will orbit at altitudes between 340km and 450km with an inclination of $${42}{^{\circ }}$$ 42 ∘ and will be subjected to background radiation from cosmic rays and solar events. It is therefore pertinent to better understand the performance of sensitive devices under space-like conditions. In this paper we focus on the radiation damage of the silicon photomultiplier arrays S13361-6075NE-04 and S14161-6050HS-04 from Hamamatsu. The S13361 are irradiated with 58MeV protons at several doses up to 4.96Gy, whereas the newer series S14161 are irradiated at doses of 0.254Gy and 2.31Gy. Their respective performance degradation due to radiation damage are discussed. The equivalent exposure time in space for silicon photomultipliers inside POLAR-2 with a dose of 4.96Gy is 62.9years (or 1.78years when disregarding the shielding from the instrument). Primary characteristics of the I-V curves are an increase in the dark current and dark counts, mostly through cross-talk events. Annealing processes at $${25}{^{\circ }C}$$ 25 ∘ C were observed but not studied in further detail. Biasing channels while being irradiated have not resulted in any significant impact. Activation analyses showed a dominant contribution of $$\beta ^{+}$$ β + particles around 511 keV. These resulted primarily from copper and carbon, mostly with decay times shorter than the orbital period.

19 April 2024 in Universe
Verified
Journal Article
Open access
PDF file
Enrico BozzoEnrico Bozzo
Enrico Bozzo
Lorenzo AmatiLorenzo Amati
Lorenzo Amati
WBWayne Baumgartner
Wayne Baumgartner
TCTzu-Ching Chang
Tzu-Ching Chang
BCBertrand Cordier
Bertrand Cordier
SZShu Zhang
Shu Zhang
Since their first discovery in the late 1960s, gamma-ray bursts have attracted an exponentially growing interest from the international community due to their central role in the most highly debated open questions of the modern research of astronomy, astrophysics, cosmology, and fundamental physics. These range from the intimate nuclear composition of high-density material within the core of ultra-dense neuron stars, to stellar evolution via the collapse of massive stars, the production and propagation of gravitational waves, as well as the exploration of the early universe by unveiling the first stars and galaxies (assessing also their evolution and cosmic re-ionization). GRBs in the past ∼50 years have stimulated the development of cutting-edge technological instruments for observations of high-energy celestial sources from space, leading to the launch and successful operations of many different scientific missions (several of them still in data-taking mode currently). In this review, we provide a brief description of the GRB-dedicated missions from space being designed and developed for the future. The list of these projects, not meant to be exhaustive, shall serve as a reference to interested readers to understand what is likely to come next to lead the further development of GRB research and the associated phenomenology.

26 June 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MKMerlin Reynaard Kole
Merlin Reynaard Kole
NANicolas De Angelis
Nicolas De Angelis
NPNicolas Produit
Nicolas Produit
FCFranck Cadoux
Franck Cadoux
YFYannick Favre
Yannick Favre
XWXin Wu
Xin Wu

1 August 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
MKMerlin Reynaard Kole
Merlin Reynaard Kole
NANicolas De Angelis
Nicolas De Angelis
ABAna Bacelj
Ana Bacelj
FCFranck Cadoux
Franck Cadoux
AEAgnieszka Elwertowska
Agnieszka Elwertowska
SZShuang-Nan Zhang
Shuang-Nan Zhang
POLAR-2 is a dedicated gamma-ray polarimeter currently foreseen to be launched towards the China Space Station around 2027. The design of the detector is based on the legacy of its predecessor mission POLAR which was launched in 2016. POLAR-2 aims to measure the polarization of the Gamma-ray Burst prompt emission within the 30–800 keV energy range. Thanks to its high sensitivity to gamma-ray polarization, as well as its large effective area, POLAR-2 will provide the most precise measurements of this type to date. Such measurements are key to improve our understanding of the astrophysical processes responsible for Gamma-Ray Bursts. The detector consists of a segmented array of plastic scintillator bars, each one of which is read out by a Silicon PhotoMultiplier channel. The flight model of POLAR-2 will contain a total of 6400 scintillators. These are divided into 100 groups of 64 bars each, in so-called polarimeter modules. In recent years, the collaboration has designed and produced the first prototypes of these polarimeter modules and subjected these to space qualification tests. In addition, in April 2023, the first of these modules were calibrated using fully polarized gamma-ray beams at the European Synchrotron Radiation Facility (ESRF) in France. In this work, we will present the results of this calibration campaign and compare these to the simulated performance of the POLAR-2 modules. Potential improvements to the design are also discussed. Finally, the measurements are used, in combination with the verified simulation framework, to estimate the scientific performance of the full POLAR-2 detector and compare it to its predecessor.

1 February 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
NANicolas De Angelis
Nicolas De Angelis
FCFranck Cadoux
Franck Cadoux
CHCoralie Husi
Coralie Husi
MKMerlin Reynaard Kole
Merlin Reynaard Kole
SMSławomir Mianowski
Sławomir Mianowski
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this kind of detectors are Compton polarimeters such as POLAR-2 [1,2,3] or LEAP [4,5,6] for which a low-Z material is needed for the Compton effect to be dominant down to as low energy as possible. Such detectors aim to measure low energy Compton depositions in organic scintillators which produce small amounts of optical light because of the low energy deposited and the low scintillation efficiency, and for which optimizing the instrumental optical properties consequently imperative. The light collection efficiency of such a device was studied with a focus on the POLAR-2 Gamma-Ray Burst polarimeter. POLAR-2 consists of a segmented array of 6400 elongated plastic scintillators divided into 100 modules, all read out by SiPMs. The conversion of incoming γ-rays into readable signal goes through the production and collection of optical light, which has been optimized both through measurements and simulations. The optical elements of the POLAR-2 polarimeter prototype module were optically characterized and an optical simulation based on Geant4 was developed to fully model its optical performances. The results from simulations were used to optimize the design and finally to verify its performance. The study resulted in a detector capable of measuring energy depositions of several keV. In addition, an important finding of this work is the impact of the plastic scintillator surface roughness on the light collection. It was found that a plastic scintillator with a higher scintillation efficiency but made of a softer material, hence with a rougher surface, was not necessarily the best option to optimize the light collection. Furthermore, in order to optimize the optical crosstalk between different channels, a production technique for very thin (∼150 μm) and reusable silicone-based optical coupling pads was developed. This method can be adapted to produce either standalone pads or to directly mold a layer on any SiPM to be later coupled to the scintillators. After an introductory discussion describing the need of a large scale GRB polarimeter like POLAR-2, the optical design and characterization of the polarimeter modules that compose its sensitive part are described. The Geant4-based optical simulations of the POLAR-2 modules and the impact of the optical properties of its various elements on the light collection efficiency of the instrument are later presented. The work is finally summarized and an outlook is given on the potential applications of the POLAR-2 optical characterization and simulation work to other experiments employing similar elements.