Deep brain stimulation (DBS) of the thalamic ventral intermediate nucleus is one of the main advanced neurosurgical treatments for drug-resistant tremor. However, not every patient may be eligible for this procedure. Nowadays, various other functional neurosurgical procedures are available. In particular cases, radiofrequency thalamotomy, focused ultrasound and radiosurgery are proven alternatives to DBS. Besides, other DBS targets, such as the posterior subthalamic area (PSA) or the dentato-rubro-thalamic tract (DRT), may be appraised as well. In this review, the clinical characteristics and pathophysiology of tremor syndromes, as well as long-term outcomes of DBS in different targets, will be summarized. The effectiveness and safety of lesioning procedures will be discussed, and an evidence-based clinical treatment approach for patients with drug-resistant tremor will be presented. Lastly, the future directions in the treatment of severe tremor syndromes will be elaborated.
7 October 2022 in Journal of Neurology, Neurosurgery & Psychiatry
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective neurosurgical treatment for Parkinson’s disease. Surgical accuracy is a critical determinant to achieve an adequate DBS effect on motor performance. A two-millimetre surgical accuracy is commonly accepted, but scientific evidence is lacking. A systematic review and meta-analysis of study-level and individual patient data (IPD) was performed by a comprehensive search in MEDLINE, EMBASE and Cochrane Library. Primary outcome measures were (1) radial error between the implanted electrode and target; (2) DBS motor improvement on the Unified Parkinson’s Disease Rating Scale part III (motor examination). On a study level, meta-regression analysis was performed. Also, publication bias was assessed. For IPD meta-analysis, a linear mixed effects model was used. Forty studies (1391 patients) were included, reporting radial errors of 0.45–1.86 mm. Errors within this range did not significantly influence the DBS effect on motor improvement. Additional IPD analysis (206 patients) revealed that a mean radial error of 1.13±0.75 mm did not significantly change the extent of DBS motor improvement. Our meta-analysis showed a huge publication bias on accuracy data in DBS. Therefore, the current literature does not provide an unequivocal upper threshold for acceptable accuracy of STN-DBS surgery. Based on the current literature, DBS-electrodes placed within a 2 mm range of the intended target do not have to be repositioned to enhance motor improvement after STN-DBS for Parkinson’s disease. However, an indisputable upper cut-off value for surgical accuracy remains to be established. PROSPERO registration number is CRD42018089539.
1 February 2023 in Neuromodulation: Technology at the Neural Interface
Objective During the surgical procedure of deep brain stimulation (DBS), insertion of an electrode in the subthalamic nucleus (STN) frequently causes a temporary improvement of motor symptoms, known as the microlesion effect (MLE). The objective of this study was to determine the correlation between the intraoperative MLE and the clinical effect of DBS. Materials and Methods Thirty Parkinson's disease (PD) patients with Movement Disorder Society (MDS) Unified Parkinson's Disease Rating Scale (UPDRS) part III (MDS-UPDRS III) scores during bilateral STN-DBS implantation were included in this retrospective study. MDS-UPDRS III subscores (resting tremor, rigidity, and bradykinesia) of the contralateral upper extremity were used. During surgery, these subscores were assessed directly before and after insertion of the electrode. Also, these subscores were determined in the outpatient clinic after 11 weeks on average (on-stimulation). All assessments were performed in an off-medication state (at least 12 hours of medication washout). Results Postinsertion MDS-UPDRS motor scores decreased significantly compared to preinsertion scores (p < 0.001 for both hemispheres). The MLE showed a positive correlation with the clinical effect of DBS in both hemispheres (rho = 0.68 for the primarily treated hemisphere, p < 0.001, and rho = 0.59 for the secondarily treated hemisphere, p < 0.01). Conclusion The MLE has a clinically relevant correlation with the effect of DBS in PD patients. These results suggest that the MLE can be relied upon as evidence of a clinically effective DBS electrode placement.
10 January 2019 in Neuromodulation: Technology at the Neural Interface
Introduction Clinical response to deep brain stimulation (DBS) strongly depends on the appropriate placement of the electrode in the targeted structure. Postoperative MRI is recognized as the gold standard to verify the DBS‐electrode position in relation to the intended anatomical target. However, intraoperative computed tomography (iCT) might be a feasible alternative to MRI. Materials and Methods In this prospective noninferiority study, we compared iCT with postoperative MRI (24‐72 hours after surgery) in 29 consecutive patients undergoing placement of 58 DBS electrodes. The primary outcome was defined as the difference in Euclidean distance between lead tip coordinates as determined on both imaging modalities, using the lead tip depicted on MRI as reference. Secondary outcomes were difference in radial error and depth, as well as difference in accuracy relative to target. Results The mean difference between the lead tips was 0.98 ± 0.49 mm (0.97 ± 0.47 mm for the left‐sided electrodes and 1.00 ± 0.53 mm for the right‐sided electrodes). The upper confidence interval (95% CI, 0.851 to 1.112) did not exceed the noninferiority margin established. The average radial error between lead tips was 0.74 ± 0.48 mm and the average depth error was determined to be 0.53 ± 0.40 mm. The linear Deming regression indicated a good agreement between both imaging modalities regarding accuracy relative to target. Conclusions Intraoperative CT is noninferior to MRI for the verification of the DBS‐electrode position. CT and MRI have their specific benefits, but both should be considered equally suitable for assessing accuracy.
The Movement Disorder Society Unified Parkinson’s Disease Rating Scale—part III (MDS-UPDRS-III) is designed to be applied in the sitting position. However, to evaluate the clinical effect during stereotactic neurosurgery or to assess bedridden patients with Parkinson’s disease (PD), the MDS-UPDRS-III is often used in a supine position. This explorative study evaluates the agreement of the MDS-UPDRS-III in the sitting and the supine positions. In 23 PD patients, the MDS-UPDRS-III was applied in both positions while accelerometric measurements were performed. Video recordings of the assessments were evaluated by two certified raters. Agreement between the sitting and supine MDS-UPDRS-III was studied using Cohen’s kappa coefficient. Relationships between the MDS-UPDRS-III tremor scores and accelerometric amplitudes were calculated for both positions with linear regression. A fair to substantial agreement was found for MDS-UPDRS-III scores of individual items in the sitting and supine positions, while combining all tests resulted in a substantial agreement. The inter-rater reliability was fair to moderate for both positions. A logarithmic relationship between tremor scores and accelerometric amplitude was revealed for both the sitting and supine positions. Nevertheless, these data are insufficient to fully support the supine application of the MDS-UPDRS-III. Several recommendations are made to address the sensitivity of the scale to inter-rater variability. In conclusion, although an overall substantial agreement between sitting and supine MDS-UPDRS-III is confirmed, its application in the supine position is not endorsed for the whole range of its individual items. Caution is warranted in interpreting the supine MDS-UPDRS-III, pending additional research.
About Me
PhD student working in the field of Neuromodulation
PhD student working in the field of Neuromodulation