There is a policy-driven focus, at present, on improving the energy performance of buildings. However, energy-related issues alone do not capture the full impact of buildings on occupants and the wider environment. The performance of a building also includes occupant wellbeing and indoor environmental quality. Specifically, in schools, indoor environmental quality (thermal comfort, indoor air quality, lighting and acoustics) is an important aspect. Additionally, the issue of the ‘performance gap’, generally focused on energy, also affects indoor environmental quality parameters and needs to be addressed holistically. This paper reports on a holistic building performance evaluation covering aspects of energy, thermal comfort, indoor air quality, lighting and acoustics. It assesses the performance issues and inter-relationships between energy and indoor environmental quality in a recently built school campus in London. Based on the evidence collated from this case study and supplementary literature, the endemic issues and constraints within the construction industry are explored, such as inappropriate design calculations and resistance to new low-carbon technologies. Further, lessons for improved performance in the design, operation and maintenance of schools are highlighted such as factoring in the changing building use trends during design and the significance of optimal operations and maintenance of building systems for better energy and indoor environmental quality performance. This study shows that if the building design focus primarily remains on energy, unintended consequence of indoor environmental quality underperformance may occur where there are conflicts between energy and indoor environmental quality objectives. An integrated approach to building performance can help address this issue. Practical application: There are often conflicts between energy efficiency and indoor environmental quality (IEQ) objectives in building design and operation. Most building performance evaluations are primarily focused on one set of these performance criteria. This building performance evaluation was done with an integrated energy and IEQ perspective. The study identifies the causes of underperformance in energy and IEQ in a recently built school in London. Some of the findings from this study provide lessons that are relevant across the industry for the delivery of low-carbon and healthy buildings. These lessons include methods to further strengthen the policy frameworks and design protocols along with overall improvements in the processes followed during design, construction and operation of schools and other non-domestic buildings. The paper can also inform building designers, contractors and facility managers about the ways to reduce the performance gap and achieve energy targets without unintended consequences for indoor environment.
Hospitals are controlled yet complex ecosystems which provide a therapeutic environment that promotes healing, wellbeing and work efficiency for patients and staff. As these buildings accommodate the sick and vulnerable, occupant wellbeing and good indoor environmental quality (IEQ) that deals with indoor air quality (IAQ), thermal comfort, lighting and acoustics are important objectives. As the specialist nature of hospital function demands highly controlled indoor environments, this makes them energy intensive buildings due to the complex and varying specifications for their functions and operations. This paper reports on a holistic building performance evaluation covering aspects of indoor air quality, thermal comfort, lighting, acoustics, and energy use. It assesses the performance issues and inter-relationships between IEQ and energy in a new building on a hospital campus in the city of Bristol, United Kingdom. The empirical evidence collated from this case study and the feedback received from the hospital staff help identify the endemic issues and constraints related to hospital buildings, such as the need for robust ventilation strategies in hospitals in urban areas that mitigate the effect of indoor and outdoor air pollution and ensuring the use of planned new low-carbon technologies. Whilst the existing guidelines for building design provide useful instructions for the protection of hospital buildings against ingress of particulate matter from outdoors, more advanced filtration strategies may be required to enact chemical reactions required to control the concentration levels of pollutants such as nitrogen dioxide and benzene. Further lessons for improved performance in operation and maintenance of hospitals are highlighted. These include ensuring that the increasingly available metering and monitoring data in new buildings, through building management systems, is used for efficient and optimal building operations for better IEQ and energy management. Overall, the study highlights the need for an integrated and holistic approach to building performance to ensure that healthy environments are provided while energy efficiency targets are met.
To manage the concerns regarding the energy performance gap in buildings, a structured and longitudinal performance assessment of buildings, covering design through to operation, is necessary. Modelling can form an integral part of this process by ensuring that a good practice design stage modelling is followed by an ongoing evaluation of operational stage performance using a robust calibration protocol. In this paper, we demonstrate, via a case study of an office building, how a good practice design stage model can be fine-tuned for operational stage using a new framework that helps validate the causes for deviations of actual performance from design intents. This paper maps the modelling based process of tracking building performance from design to operation, identifying the various types of performance gaps. Further, during the operational stage, the framework provides a systematic way to separate the effect of (i) operating conditions that are driven by the building’s actual function and occupancy as compared with the design assumptions, and (ii) the effect of potential technical issues that cause underperformance. As the identification of issues is based on energy modelling, the process requires use of advanced and well-documented simulation tools. The paper concludes with providing an outline of the software platform requirements needed to generate robust design models and their calibration for operational performance assessments. The paper’s findings are a useful guide for building industry professionals to manage the performance gap with appropriate accuracy through a robust methodology in an easy to use workflow. The methodological framework to analyse building energy performance in-use links best practice design stage modelling guidance with a robust operational stage investigation. It helps designers, contractors, building managers and other stakeholders with an understanding of procedures to follow to undertake an effective measurement and verification exercise.
1 September 2021 in Diabetes & Metabolic Syndrome: Clinical Research & Reviews
The construction industry contributes significantly to energy consumption and carbon emissions. Moreover, people spend more time inside buildings, so their health is increasingly influenced by indoor environmental conditions. When considered through these lenses, the concept of total building performance can span energy consumption, the associated CO2 emissions, and indoor environmental quality (IEQ). At the individual project level, building underperformance with respect to energy and IEQ is frequent, and the ex post performance gap is partially attributed to the construction project management and operations phase of the building lifecycle. This underperformance motivates the research of this paper into the construction process outcomes in terms of energy performance and IEQ, and ways to reduce the performance gap. The paper develops a multi-methodology framework to analyse the effect of building development project process on energy performance and IEQ from an operations management perspective. The framework couples system dynamics modelling of construction project management to building performance modelling. The paper details the way they are coupled, the application steps and data requirements, so that they can be applied on a case by case basis. The aim is to combine operations management to building performance disciplines and deliver insights for industry practitioners and policy makers.