A comprehensive analysis of in vitro pumps used in cardiovascular research is provided in this review, with a focus on the characteristics of generated flows and principles of flow generations. The cardiovascular system, vital for nutrient circulation and waste removal, generates complex hemodynamics critical for endothelial cell function. Cardiovascular diseases (CVDs) could be caused by the disturbances in these flows, including aneurysms, atherosclerosis, and heart defects. In vitro systems simulate hemodynamic conditions on cultured cells in the laboratory to study and evaluate these diseases to advance therapies. Pumps used in these systems can be classified into contact and non-contact types. Contact pumps, such as piston and gear pumps, can generate higher flow rates, but they have a higher risk of contamination due to the direct interaction of pump with the fluid. Non-contact pumps, such as peristaltic and lab-on-disk centrifugal pumps, minimize contamination risks, but they are limited to lower flow rates. Advanced pumps including piezoelectric and I-Cor diagonal pumps are focused on improving the accuracy of flow replication and long-term stability. The operational principles, advantages, and some disadvantages of these pump categories are evaluated in this review, while providing insights for optimizing in vitro cardiovascular models and advancing therapeutic strategies against CVDs. The outcomes of the review elaborate the importance of selecting an appropriate pump system, to accurately replicate cardiovascular flow patterns.
Background/Objectives: For transcatheter aortic valve implantation (TAVI) therapy, a catheter-guided crimped valve is deployed into the aortic root. Valve types such as Edwards balloon-expandable valves and Medtronic self-expandable valves come in different sizes and are chosen based on patient-specific aortic anatomy, including aortic root diameter measurement. Complications may arise due to variations in anatomical characteristics and the implantation procedure, making pre-implantation assessment important for predicting complications. Methods: Computational modeling, particularly finite element analysis (FEA), has become popular for assessing wall stresses and deformations in TAVI. In this study, a finite element model including the aorta, native leaflets, and TAVI device was used to simulate procedures and assess patient-specific wall stresses and deformations. Results: Using the Medtronic Evolut R valve, we simulated TAVI for 14 patients to analyze the effects of geometrical variations on structural stresses. Virtual TAVIs with different valve sizes were also simulated to study the influence of TAV size on stresses. Our results show that variations in aortic wall geometries and TAV sizes significantly influence wall stresses and deformations. Conclusions: Our study is one of the first comprehensive FEA investigations of aortic geometrical variations and valve sizes on post-TAVI stresses, demonstrating the non-linear relationship between aortic dimensions, TAV sizes, and wall stresses.
1 April 2026 in Journal of the Heart Valve Society
Cardiovascular disease remains the leading cause of noncommunicable mortality globally, with aortic valve (AV) disorders, especially aortic stenosis (AS), representing a substantial burden. Transcatheter aortic valve implantation (TAVI) is an effective treatment for AS, where selecting the correct valve size is crucial and preimplantation mechanical assessment is desirable to predict possible complications that may occur post-TAVI. Finite-element analysis (FEA) is a powerful technique for predicting wall stresses, such as contact pressure and von Mises stresses. Predicting post-TAVI complications such as conduction abnormalities and paravalvular leakage is challenging. FEA is useful for that purpose, but it is technically demanding and time-consuming. This study introduces a deep learning (DL) approach to efficiently predict patient-specific aortic wall stresses for the TAVI procedure. We collaborated with Hamad Heart Hospital’s TAVI program, analyzing computed tomography (CT) data and implanted valve information from 55 patients. We conducted FEA for virtual implantation simulations to derive contact pressures and von Mises stresses. Using a graph neural network model that features SageConv and SplineConv layers within a Geometric PointNet architecture, we trained on data that included the actual implanted valve size and simulations with marginally smaller and larger sizes on the same patients to enhance training variability. Our model achieved a normalized mean squared error of 0.0020 for contact pressure and 0.0057 for von Mises stress predictions. Integrating the pre-TAVI aortic geometry with FEA results significantly improved prediction accuracy for contact pressure, though alignment of von Mises stress predictions was occasionally inconsistent.