Norin FORNA

Dr. Norin FORNA

UMF Grigore T Popa Iasi, Iaşi, Romania
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
LSLiliana Savin
Liliana Savin
TPTudor Pinteala
Tudor Pinteala
DMDana Nicoleta Mihai
Dana Nicoleta Mihai
DMDan Mihailescu
Dan Mihailescu
SMSmaranda Stefana Miu
Smaranda Stefana Miu
NFNorin FORNA
Norin FORNA
One of the most popular and effective orthopedic surgical interventions for treating a variety of hip diseases is total hip arthroplasty. Despite being a radical procedure that involves replacing bone and cartilaginous surfaces with biomaterials, it produces excellent outcomes that significantly increase the patient’s quality of life. Patient factors and surgical technique, as well as biomaterials, play a role in prosthetic survival, with aseptic loosening (one of the most common causes of total hip arthroplasty failure) being linked to the quality of biomaterials utilized. Over the years, various biomaterials have been developed to limit the amount of wear particles generated over time by friction between the prosthetic head (metal alloys or ceramic) and the insert fixed in the acetabular component (polyethylene or ceramic). An ideal biomaterial must be biocompatible, have a low coefficient of friction, be corrosion resistant, and have great mechanical power. Comprehensive knowledge regarding what causes hip arthroplasty failure, as well as improvements in biomaterial quality and surgical technique, will influence the survivability of the prosthetic implant. The purpose of this article was to assess the benefits and drawbacks of various biomaterial and friction couples used in total hip arthroplasties by reviewing the scientific literature published over the last 10 years.

25 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Ana-Iulia BițaAna-Iulia Bița
Ana-Iulia Bița
Antoniac IulianAntoniac Iulian
Antoniac Iulian
MMMarian Miculescu
Marian Miculescu
George StanGeorge Stan
George Stan
Lucia LeonatLucia Leonat
Lucia Leonat
NFNorin FORNA
Norin FORNA
The use of resorbable magnesium alloys in the design of implants represents a new direction in the healthcare domain. Two main research avenues are currently explored for developing or improving metallic biomaterials: (i) increase of their corrosion resistance by designed compositional and structural modifications, and (ii) functionalization of their surfaces by coating with ceramic or polymeric layers. The main objective of this work was to comparatively assess bio-functional coatings (i.e., highly-crystallized hydroxyapatite and silica-rich glass) deposited by radio-frequency magnetron sputtering (RF-MS) on a biodegradable Mg-0.8Ca alloy (0.8 wt.% of Ca). After probing their morphology (by scanning electron microscopy) and structure (by Fourier transform infrared spectroscopy and grazing incidence X-ray diffraction), the corrosion resistance of the RF-MS coated Mg-0.8Ca substrates was electrochemically tested (in synthetic biological media with different degrees of biomimicry), and their cytocompatibility was assessed in osteoblast and fibroblast cell cultures. By collective assessment, the most promising performances, in terms of mass loss (~7% after 12 days), hydrogen release rate (~6 mL/cm2 after 12 days), electrochemical corrosion parameters and cytocompatibility, were obtained for the crystalline HA coating.

15 February 2008 in European Journal of Dental Education
Verified
Journal Article
Open access
PDF file
DND. Nash
D. Nash
JRJ. Ruotoistenmäki
J. Ruotoistenmäki
AAA. Argentieri
A. Argentieri
SBS. Barna
S. Barna
JBJ. Behbehani
J. Behbehani
EHE. Honkala
E. Honkala
Health is a critical dimension of human well‐being and flourishing, and oral health is an integral component of health: one is not healthy without oral health. Significant barriers exist to ensuring the world’s people receive basic healthcare, including oral healthcare. Amongst these are poverty, ignorance, inadequate financial resources and lack of adequate numbers of educated and trained (oral) healthcare workers. Emerging economies are encouraged to develop a national strategic plan for oral health. International organizations have developed goals for oral health that can be referenced and adapted by emerging economies as they seek to formulate specific objectives for their countries. Demographic data that assess the nature and extent of oral diseases in a country are essential to sound planning and the development of an oral healthcare system that is relevant, effective and economically viable. Prevention should be emphasized and priority consideration be given to oral healthcare for children.The types and numbers of members of the oral healthcare team (workforce) will vary from country to country depending on the system developed. Potential members of the workforce include: generalist dentists, specialist dentists, dental therapists, dental hygienists, denturists, expanded function dental assistants (dental nurses) and community oral health workers/aides. Competences for dentists, and other members of the team, should be developed to ensure quality care and developed economies should cooperate with emerging economies. The development, by more advanced economies, of digital, virtual curricula, which could be used by emerging economies for educating and training members of the oral healthcare team, should be an important initiative. The International Federation of Dental Educators and Associations (IFDEA) should lead in such an effort.

19 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
ARAlina Robu
Alina Robu
RCRobert Ciocoiu
Robert Ciocoiu
AAAntoniac Aurora
Antoniac Aurora
Antoniac IulianAntoniac Iulian
Antoniac Iulian
ARAnca Daniela Raiciu
Anca Daniela Raiciu
ICIoana Cârstoc
Ioana Cârstoc
The failure of hip prostheses is a problem that requires further investigation and analysis. Although total hip replacement is an extremely successful operation, the number of revision surgeries needed after this procedure is expected to continue to increase due to issues with both bone cement types and cementation techniques (depending on the producer). To conduct a comparative analysis, as a surgeon prepared the bone cement and introduced it in the body, this study’s team of researchers prepared three types of commercial bone cements with the samples mixed and placed them in specimens, following the timeline of the surgery. In order to evaluate the factors that influenced the chemical composition and structure of each bone cement sample under specific intraoperative conditions, analyses of the handling properties, mechanical properties, structure, and composition were carried out. The results show that poor handling can impede prosthesis–cement interface efficacy over time. Therefore, it is recommended that manual mixing be avoided as much as possible, as the manual preparation of the cement can sometimes lead to structural unevenness.

8 June 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
MCMihai Alexandru Cordunianu
Mihai Alexandru Cordunianu
Antoniac IulianAntoniac Iulian
Antoniac Iulian
MNMarius Niculescu
Marius Niculescu
Gheorghe PaltaneaGheorghe Paltanea
Gheorghe Paltanea
ARAnca Daniela Raiciu
Anca Daniela Raiciu
BCBogdan Mihai Cristea
Bogdan Mihai Cristea
Osteochondral lesions (OCLs) that are frequently encountered in skeletally immature and adult patients are more common than once thought, and their incidence rate is rising. These lesions can appear in many synovial joints of the body, such as the shoulder, elbow, hip, and ankle, occurring most often in the knee. The term osteochondral lesion includes a vast spectrum of pathologies such as osteochondritis dissecans, osteochondral defects, osteochondral fractures, and osteonecrosis of the subchondral bone. When considering this, the term osteochondral fracture is preserved only for an osteochondral defect that combines disruption of the articular cartilage and subchondral bone. These fractures commonly occur after sports practice and are associated with acute lateral patellar dislocations. Many of these lesions are initially diagnosed by plain radiographs; however, a computed tomography (CT) scan or magnetic resonance imaging (MRI) can add significant value to the diagnosis and treatment. Treatment methods may vary depending on the location and size of the fracture, fragment instability, and skeletal maturity. The paper reports a 14-year-old boy case with an osteochondral fracture due to sports trauma. The medical approach involved an arthrotomy of the knee, drainage of the hematoma, two Kirschner wires (K-wires) for temporary fixation to restructure anatomic alignment, and a titanium Herbert screw fixing the fracture permanently. The patient had a favorable postoperative outcome with no residual pain, adequate knee stability, and a normal range of motion. The mobility of the knee was fully recovered.

14 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NFNorin FORNA
Norin FORNA
DDDaniela Damir
Daniela Damir
LDLetitia Doina Duceac
Letitia Doina Duceac
MDMarius Dabija
Marius Dabija
GABRIELA CALIN (MIHALACHE)GABRIELA CALIN (MIHALACHE)
GABRIELA CALIN (MIHALACHE)
CMConstantin Marcu
Constantin Marcu
Recently, nanotechnology research studies have been proven that use of various nanoparticles as drug delivery systems to target and to annihilate pathogenic microorganisms may be a good solution for prevention and treatment of severe infection. In the last few years, antimicrobial drug encapsulation into nano-sized systems has materialized as a promising alternative that increased drug efficacy and minimized adverse effects. Physicochemical properties of erythromycin-loaded polymer nanoparticles were assessed using particle size distribution, HPLC, FTIR, TG/DTA, and SEM characterization techniques. The as-prepared samples exhibited an average particle size of 340 and 270 nm, respectively, with erythromycin content of 99.7% in both samples. From the release profile of erythromycin from PLA/PLGA, a prolonged drug release can be observed from both Ery-PLA and Ery-PLGA nanostructures. Morphology images exhibited spherical, rigid, and ring-shaped nanoparticles. Thermal analytical study in the case of Ery-PLA and Ery-PLGA samples showed that pure drug has an endothermic peak at around 150 °C assigned to a melting point. The antibiotic melting peak disappeared for both antibiotic-loaded PLA and PLGA nanoparticles thermographs, denoting the presence of erythromycin. This indicates that the antibiotic is uniformly dispensed throughout the host polymer matrix at nanometer scale. FTIR spectra of Ery-PLA and Ery-PLGA nano-architectures with almost similar peaks indicated no alteration in chemical structure of drug-loaded polymer nanoparticles.