Olivier Schalm

Dr. Olivier Schalm

Antwerp Maritime Academy, Antwerp, Flanders, Belgium
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2007 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
Olivier SchalmOlivier Schalm
Olivier Schalm
Koen Henri JanssensKoen Henri Janssens
Koen Henri Janssens
HWHilde Wouters
Hilde Wouters
DCDanielle Caluwé
Danielle Caluwé

10 September 2009 in Archaeometry
Verified
Journal Article
Closed access
PDF file
VLV. VAN DER Linden
V. VAN DER Linden
PCP. Cosyns
P. Cosyns
Olivier SchalmOlivier Schalm
Olivier Schalm
SCS. Cagno
S. Cagno
KNK. Nys
K. Nys
EBE. Bulska
E. Bulska

1 January 2009 in Journal of Cultural Heritage
Verified
Journal Article
Closed access
DVDelphine Vandevoorde
Delphine Vandevoorde
Marisa PamplonaMarisa Pamplona
Marisa Pamplona
Olivier SchalmOlivier Schalm
Olivier Schalm
YVYves Vanhellemont
Yves Vanhellemont
Veerle CnuddeVeerle Cnudde
Veerle Cnudde
EVEddy Verhaeven
Eddy Verhaeven

8 March 2002 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
DJD. Jembrih-Simbürger
D. Jembrih-Simbürger
CNC. Neelmeijer
C. Neelmeijer
Olivier SchalmOlivier Schalm
Olivier Schalm
PFP. Fredrickx
P. Fredrickx
MSM. Schreiner
M. Schreiner
JCJ. Caen
J. Caen
Glass treated on its surface with silver compounds and an aluminosilicate, such as ochre or clay, at higher temperatures (between 550 and 650 °C) accepts a wide variety of a yellow colour. It is the aim of this study to investigate the parameters of the manufacturing process affecting the final colour of silver stained glass and to correlate them with the final colour and colour intensity. Therefore, defined mixtures of ochre and a silver compound (AgCl, AgNO3, Ag2SO4, Ag3PO4, Ag2O) were prepared and applied on soda-lime glass. The firing process was modified within the range from 563 to 630 °C and glass samples were analysed after treatment with energy dispersive X-ray fluorescence analysis (EDXRF), scanning electron microscopy (SEM/EDX), transmission electron microscopy (TEM), as well as ion beam analysis (IBA) with an external beam. Within the scope of IBA simultaneous measurements using particle-induced X-ray emission (PIXE), particle-induced gamma-ray emission (PIGE), and Rutherford backscattering spectrometry (RBS) were carried out in order to obtain the thickness of the Ag-rich surface layer and the depth distribution of Ag. By means of TEM the microstructure of the silver particles was visualised. XRF results show that the lowest amount of Ag could be detected on glass samples treated with silver stain mixtures containing AgCl and Ag2O. A low kiln temperature (e.g. 563 °C) results in a higher silver concentration at the surface and lower penetration depths. Furthermore, the results obtained with SEM/EDX at cross-sections of the glass samples could be confirmed by PIXE, PIGE, RBS, and TEM.

16 December 2010 in Archaeometry
Verified
Journal Article
Closed access
PDF file
Olivier SchalmOlivier Schalm
Olivier Schalm
KPK. Proost
K. Proost
KVK. DE Vis
K. DE Vis
SCS. Cagno
S. Cagno
Koen Henri JanssensKoen Henri Janssens
Koen Henri Janssens
JCJ. Caen
J. Caen

17 January 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
Rosa Amalia González RiveroRosa Amalia González Rivero
Rosa Amalia González Rivero
LHLuis Ernesto Morera Hernández
Luis Ernesto Morera Hernández
Olivier SchalmOlivier Schalm
Olivier Schalm
ERErik Hernández Rodríguez
Erik Hernández Rodríguez
DSDaniellys Alejo Sánchez
Daniellys Alejo Sánchez
Alain MartinezAlain Martinez
Alain Martinez
Low-cost sensors provide an affordable alternative to monitor environmental parameters with acceptable performance. There is a substantial amount of literature where low-cost sensors are compared with high-end reference measurements. However, not all organizations have access to such reference infrastructure. We propose low-cost calibration methods for temperature, relative humidity, and CO2 to allow them to collect their own reliable data. These methods are based on simple techniques and procedures that allow temperature calibration to be achieved in the range of 0 to 50 °C, relative humidity from 0 to 90%, and CO2 between 0 and 1100 ppm. The materials used to create the calibration setups can be purchased online, at hardware stores, and in pharmacies. The reliability of the calibration methods was evaluated using several indicators, such as the airtightness of the calibration box, similarity with the factory calibration, similarity with the reference, similarity between different sensors, replicability of the calibration method, and the similarity with a golden standard. In addition, the results of the low-cost calibration methods were compared with the more advanced calibration methods. A short measurement campaign in the city of Santa Clara, Cuba, demonstrated that such calibrations transform in-house developed monitoring systems into valid low-cost scientific instruments for decision-making. This work creates opportunities for institutions and researchers hosted in low- and mid-income countries to build and validate their own equipment to reliably solve local problems.