Low-cost sensors provide an affordable alternative to monitor environmental parameters with acceptable performance. There is a substantial amount of literature where low-cost sensors are compared with high-end reference measurements. However, not all organizations have access to such reference infrastructure. We propose low-cost calibration methods for temperature, relative humidity, and CO2 to allow them to collect their own reliable data. These methods are based on simple techniques and procedures that allow temperature calibration to be achieved in the range of 0 to 50 °C, relative humidity from 0 to 90%, and CO2 between 0 and 1100 ppm. The materials used to create the calibration setups can be purchased online, at hardware stores, and in pharmacies. The reliability of the calibration methods was evaluated using several indicators, such as the airtightness of the calibration box, similarity with the factory calibration, similarity with the reference, similarity between different sensors, replicability of the calibration method, and the similarity with a golden standard. In addition, the results of the low-cost calibration methods were compared with the more advanced calibration methods. A short measurement campaign in the city of Santa Clara, Cuba, demonstrated that such calibrations transform in-house developed monitoring systems into valid low-cost scientific instruments for decision-making. This work creates opportunities for institutions and researchers hosted in low- and mid-income countries to build and validate their own equipment to reliably solve local problems.
Poor air quality is a global problem that affects human health and ecosystems all over the world. For that reason, many countries invest in networks of reference monitoring stations that measure air quality in real time. However, the high installation and maintenance costs of these stations mean that smaller cities or underdeveloped regions are less covered by such stations. In these regions, alternative detection technologies such as low-cost monitoring systems can be used instead. Unfortunately, the results of such monitoring devices are often questioned by academics. This contribution proposes the design of an air quality monitoring system where cost and reliability have been optimized from a hardware point of view. In addition, the device has been coupled to an IoT platform so that inexperienced users can view and share the collected information The design of affordable systems increases the ability to perform ad hoc analysis at the level of neighborhoods or cities by citizen science organizations or governmental entities.
In the Western world, the SO2 concentration in ambient air dropped to low levels, but some emission sources (e.g., merchant ships) and some regions (e.g., low-income countries) still emit substantial amounts of SO2. At those locations, SO2 monitoring is critical. However, low-income countries do not have much access to expensive reference instruments. Low-cost gas sensors might be an alternative, but it is unclear how reliable such measurements are. To evaluate the performance of the low-cost alternative, the same SO2 gas sensor has been subjected to three different calibration methods: (1) low-cost calibration performed in the tropical climate of Cuba; (2) high-end calibration performed in Belgium; (3) a field calibration at an air quality measuring station in Belgium. The first two methods showed similar trends, suggesting that the gas sensor can be calibrated with a low-cost method. The field calibration was hampered by the low SO2 concentrations. For the monitoring campaign in Cienfuegos, Cuba, the low-cost SO2 sensor calibrated by the low-cost method appeared to be sufficiently reliable. The reliability of the sensor increases with the increase in SO2 concentration, so it can be used in Cuba instead of Belgium.
This contribution shows the possibilities of applying a low-cost, multi-purpose data logger built around an Arduino Mega 2560 single-board computer. Most projects use this kind of hardware to develop single-purpose data loggers. In this work, a data logger with a more general hardware and software architecture was built to perform measurement campaigns in very different domains. The wide applicability of this data logger was demonstrated with short-term monitoring campaigns in relation to outdoor air quality, human activity in an office, motion of a journey on a bike, and exhaust gas monitoring of a diesel generator. In addition, an assessment process and corresponding evaluation framework are proposed to assess the credibility of low-cost scientific devices built in-house. The experiences acquired during the development of the system and the short measurement campaigns were used as inputs in the assessment process. The assessment showed that the system scores positively on most product-related targets. However, unexpected events affect the assessment over the longer term. This makes the development of low-cost scientific devices harder than expected. To assure stability and long-term performance of this type of design, continuous evaluation and regular engineering corrections are needed throughout longer testing periods.
4 December 2012 in Environmental Monitoring and Assessment