Anatoliy Pavlenko

Prof. Dr. Anatoliy Pavlenko

Kielce University of Technology, Poland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
Anatoliy PavlenkoAnatoliy Pavlenko
Anatoliy Pavlenko
Hanna KoshlakHanna Koshlak
Hanna Koshlak
In this paper, the authors consider the processes of dynamic interaction between the boiling particles of the dispersed phase of the emulsion leading to the large droplet breakup. Differences in the consideration of forces that determine the breaking of non-boiling and boiling droplets have been indicated in the study. They have been determined by the possibility of using the model to define the processes of displacement, deformation, or fragmentation of the inclusion of the dispersed phase under the influence of a set of neighboring particles. The dynamics of bubbles in a compressible liquid with consideration for interfacial heat and mass transfer has also been analyzed in the paper. The effect of standard and system parameters on the intensity of cavitation processes is considered. Physical transformations during the cavitation treatment of liquid are caused not only by shock waves and radiated pressure pulses but also by extreme thermal effects. At the stage of ultimate bubble compression, vapor inside the bubble and the liquid in its vicinity transform into the supercritical fluid state. The model analyzes microflow features in the inter-bubble space and quantitatively calculates local values of the velocity and pressure fields, as well as dynamic effects.

30 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Victoria KornienkoVictoria Kornienko
Victoria Kornienko
RRRoman Radchenko
Roman Radchenko
Mykola RadchenkoMykola Radchenko
Mykola Radchenko
ARAndrii Radchenko
Andrii Radchenko
Anatoliy PavlenkoAnatoliy Pavlenko
Anatoliy Pavlenko
Dmytro KonovalovDmytro Konovalov
Dmytro Konovalov
The fuel efficiency of marine diesel engine as any combustion engine falls with raising the temperature of air at the suction of its turbocharger. Therefore, cooling the engine turbocharger intake air by recovering exhaust gas heat to refrigeration capacity is a very perspective trend in enhancing the fuel efficiency of marine diesel engines. The application of water-fuel emulsion (WFE) combustion enables the reduction of a low-temperature corrosion, and, as a result, provides deeper exhaust gas heat utilization in the exhaust gas boiler (EGB) to the much lower temperature of 90–110 °C during WFE instead of 150–170 °C when combusting conventional fuel oil. This leads to the increment of the heat extracted from exhaust gas that is converted to refrigeration capacity by exhaust heat recovery chiller for cooling engine turbocharger sucked air accordingly. We experimentally investigated the corrosion processes on the condensation surfaces of EGB during WFE combustion to approve their intensity suppression and the possibility of deeper exhaust gas heat utilization. The fuel efficiency of cooling intake air at the suction of engine turbocharger with WFE combustion by exhaust heat recovery chiller was estimated along the voyage line Mariupol–Amsterdam–Mariupol. The values of available refrigeration capacity of exhaust heat recovery chiller, engine turbocharger sacked air temperature drop, and corresponding reduction in specific fuel consumption of the main low-speed diesel engine at varying actual climatic conditions on the voyage line were evaluated.

4 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
ARAndrii Radchenko
Andrii Radchenko
Mykola RadchenkoMykola Radchenko
Mykola Radchenko
DMDariusz Mikielewicz
Dariusz Mikielewicz
Anatoliy PavlenkoAnatoliy Pavlenko
Anatoliy Pavlenko
RRRoman Radchenko
Roman Radchenko
SFSerhiy Forduy
Serhiy Forduy
The trigeneration plants for combined cooling, heating, and electricity supply, or integrated energy systems (IES), are mostly based on gas reciprocating engines. The fuel efficiency of gas reciprocating engines depends essentially on air intake temperatures. The transformation of the heat removed from the combustion engines into refrigeration is generally conducted by absorption lithium-bromide chillers (ACh). The peculiarity of refrigeration generation in food technologies is the use of chilled water of about 12 °C instead of 7 °C as the most typical for ACh. This leads to a considerable cooling potential not realized by ACh that could be used for cooling the engine intake air. A refrigerant ejector chiller (ECh) is the simplest in design, cheap, and can be applied as the low-temperature stage of a two-stage absorption-ejector chiller (AECh) to provide engine intake air cooling and increase engine fuel efficiency as result. The monitoring data on gas engine fuel consumption and power were analyzed in order to evaluate the effect of gas engine cyclic air cooling.

24 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
ZYZongming Yang
Zongming Yang
Victoria KornienkoVictoria Kornienko
Victoria Kornienko
Mykola RadchenkoMykola Radchenko
Mykola Radchenko
ARAndrii Radchenko
Andrii Radchenko
RRRoman Radchenko
Roman Radchenko
Anatoliy PavlenkoAnatoliy Pavlenko
Anatoliy Pavlenko
One of the most effective methods towards improving the environmental safety of combustion engines is the application of specially prepared water-fuel emulsions (WFE). The application of WFE makes it possible to reduce primary sulfur fuel consumption and reveals the possibility of capturing the pollutants from exhaust gases by applying condensing low-temperature heating surfaces (LTHS). In order to realize such a double effect, it is necessary to investigate the pollution processes on condensing LTHS of exhaust gas boilers (EGB), especially the process of low-temperature condensing a sulfuric acid vapor from exhaust gases to investigate the influence of condensing LTHS on the intensity of pollutants captured from the exhaust gases. The aim of this research is to assess the influence of the intensity of pollutants captured from exhaust gases by condensing LTHS in dependence of water content in WFE combustion. Investigations were carried out at a special experimental setup. The processing of the results of the experimental studies was carried out using the computer universal statistical graphic system Statgraphics. Results have shown that in the presence of a condensing heating surface, the degree of capture (purification) of pollutants from the exhaust gas flow is up to 0.5–0.6.

30 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Mykola RadchenkoMykola Radchenko
Mykola Radchenko
ARAndrii Radchenko
Andrii Radchenko
ETEugeniy Trushliakov
Eugeniy Trushliakov
Anatoliy PavlenkoAnatoliy Pavlenko
Anatoliy Pavlenko
RRRoman Radchenko
Roman Radchenko
All the energetic management and controlling strategies in ambient air conditioning systems (ACS) are aimed to match design load to current needs. This might be achieved by determining a rational value of design thermal load without overestimation that can minimize its deviation from the actual values. The application of variable refrigerant flow (VRF) systems with speed-regulated compressors (SRC) is considered as the most advanced trend in building air conditioning due to the ability of SRCs to cover changeable heat loads without lowering their efficiency. The level of load regulation by SRC is evaluated as the ratio of the load range, regulated by SCR, to the overall design load range. With this, the range of actual changeable loads is usually supposed to be covered by SRC entirely while keeping the rest, unregulated, and load range unchangeable. However, to confirm this, the rest load range behind the regulated one should be investigated to estimate the efficiency of SRC operation. Therefore, the approach to dividing the overall thermal load range of ambient air conditioning into the ranges of changeable and unchangeable loads to compare with those covered by SRC is used. From this approach, the method of rational designing and shearing a design refrigeration capacity in response to current loading, based on the principle of two-stage ambient air conditioning, has been widened on the VRF systems to estimate the efficiency of SCR application. This was realized by imposing the load ranges regulated by SRC onto the ranges of changeable and unchangeable loads within the overall range of actual loading. The proposed innovative criteria and indicators for rational shearing the load ranges to match current duties and load level evaluation can reveal the reserves for improving the efficiency of SRC compressor operation and the ACS of VRF type as a whole.

7 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
BBBorys Basok
Borys Basok
BDBorys Viktorovich Davydenko
Borys Viktorovich Davydenko
Anatoliy PavlenkoAnatoliy Pavlenko
Anatoliy Pavlenko
The article presents the modeling of the dynamics of the vapor-gas mixture and heat and mass transfer (sorption-desorption) in the capillary structure of the porous medium. This approach is underpinned by the fact that the porous structure is represented by a system of linear microchannels oriented along the axes of a three-dimensional coordinate system. The equivalent diameter of these channels corresponds to the average pore diameter, and the ratio of the total pore volume to the volume of the entire porous material corresponds to its porosity. The entire channel area is modeled by a set of cubic elements with a certain humidity, moisture content, pressure and temperature. A simulation is carried out taking into account the difference in temperatures of each of the phases: solid, liquid and gas.