Orhan YAMAN

Prof. Dr. Orhan YAMAN

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SKSabiha Gungor Kobat
Sabiha Gungor Kobat
NBNursena BAYGIN
Nursena BAYGIN
EYElif Yusufoglu
Elif Yusufoglu
MBMehmet Baygin
Mehmet Baygin
Prabal Datta BaruaPrabal Datta Barua
Prabal Datta Barua
U Rajendra AcharyaU Rajendra Acharya
U Rajendra Acharya
Diabetic retinopathy (DR) is a common complication of diabetes that can lead to progressive vision loss. Regular surveillance with fundal photography, early diagnosis, and prompt intervention are paramount to reducing the incidence of DR-induced vision loss. However, manual interpretation of fundal photographs is subject to human error. In this study, a new method based on horizontal and vertical patch division was proposed for the automated classification of DR images on fundal photographs. The novel sides of this study are given as follows. We proposed a new non-fixed-size patch division model to obtain high classification results and collected a new fundus image dataset. Moreover, two datasets are used to test the model: a newly collected three-class (normal, non-proliferative DR, and proliferative DR) dataset comprising 2355 DR images and the established open-access five-class Asia Pacific Tele-Ophthalmology Society (APTOS) 2019 dataset comprising 3662 images. Two analysis scenarios, Case 1 and Case 2, with three (normal, non-proliferative DR, and proliferative DR) and five classes (normal, mild DR, moderate DR, severe DR, and proliferative DR), respectively, were derived from the APTOS 2019 dataset. These datasets and these cases have been used to demonstrate the general classification performance of our proposal. By applying transfer learning, the last fully connected and global average pooling layers of the DenseNet201 architecture were used to extract deep features from input DR images and each of the eight subdivided horizontal and vertical patches. The most discriminative features are then selected using neighborhood component analysis. These were fed as input to a standard shallow cubic support vector machine for classification. Our new DR dataset obtained 94.06% and 91.55% accuracy values for three-class classification with 80:20 hold-out validation and 10-fold cross-validation, respectively. As can be seen from steps of the proposed model, a new patch-based deep-feature engineering model has been proposed. The proposed deep-feature engineering model is a cognitive model, since it uses efficient methods in each phase. Similar excellent results were seen for three-class classification with the Case 1 dataset. In addition, the model attained 87.43% and 84.90% five-class classification accuracy rates using 80:20 hold-out validation and 10-fold cross-validation, respectively, on the Case 2 dataset, which outperformed prior DR classification studies based on the five-class APTOS 2019 dataset. Our model attained about >2% classification results compared to others. These findings demonstrate the accuracy and robustness of the proposed model for classification of DR images.

5 March 2022 in Artificial Intelligence in Medicine
Verified
Journal Article
Closed access
MBMehmet Baygin
Mehmet Baygin
OYOrhan YAMAN
Orhan YAMAN
Prabal Datta BaruaPrabal Datta Barua
Prabal Datta Barua
Sengul DoganSengul Dogan
Sengul Dogan
Türker TuncerTürker Tuncer
Türker Tuncer
U Rajendra AcharyaU Rajendra Acharya
U Rajendra Acharya


11 February 2020 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Mehmet KARAKÖSEMehmet KARAKÖSE
Mehmet KARAKÖSE
OYOrhan YAMAN
Orhan YAMAN

16 September 2022 in Microprocessors and Microsystems
Verified
Journal Article
Closed access
OYOrhan YAMAN
Orhan YAMAN
FYFerhat Yol
Ferhat Yol
AAAyhan Altinors
Ayhan Altinors

Prabal Datta BaruaPrabal Datta Barua
Prabal Datta Barua
Nadia Fareeda Muhammad GowdhNadia Fareeda Muhammad Gowdh
Nadia Fareeda Muhammad Gowdh
KRKartini Rahmat
Kartini Rahmat
NRNORLISAH MOHD RAMLI
NORLISAH MOHD RAMLI
WNWei Lin Ng
Wei Lin Ng
U Rajendra AcharyaU Rajendra Acharya
U Rajendra Acharya
COVID-19 and pneumonia detection using medical images is a topic of immense interest in medical and healthcare research. Various advanced medical imaging and machine learning techniques have been presented to detect these respiratory disorders accurately. In this work, we have proposed a novel COVID-19 detection system using an exemplar and hybrid fused deep feature generator with X-ray images. The proposed Exemplar COVID-19FclNet9 comprises three basic steps: exemplar deep feature generation, iterative feature selection and classification. The novelty of this work is the feature extraction using three pre-trained convolutional neural networks (CNNs) in the presented feature extraction phase. The common aspects of these pre-trained CNNs are that they have three fully connected layers, and these networks are AlexNet, VGG16 and VGG19. The fully connected layer of these networks is used to generate deep features using an exemplar structure, and a nine-feature generation method is obtained. The loss values of these feature extractors are computed, and the best three extractors are selected. The features of the top three fully connected features are merged. An iterative selector is used to select the most informative features. The chosen features are classified using a support vector machine (SVM) classifier. The proposed COVID-19FclNet9 applied nine deep feature extraction methods by using three deep networks together. The most appropriate deep feature generation model selection and iterative feature selection have been employed to utilise their advantages together. By using these techniques, the image classification ability of the used three deep networks has been improved. The presented model is developed using four X-ray image corpora (DB1, DB2, DB3 and DB4) with two, three and four classes. The proposed Exemplar COVID-19FclNet9 achieved a classification accuracy of 97.60%, 89.96%, 98.84% and 99.64% using the SVM classifier with 10-fold cross-validation for four datasets, respectively. Our developed Exemplar COVID-19FclNet9 model has achieved high classification accuracy for all four databases and may be deployed for clinical application.