Maurizio Ortolani

Mr. Maurizio Ortolani

Istituto Ortopedico Rizzoli, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Alberto LeardiniAlberto Leardini
Alberto Leardini
GLGiada Lullini
Giada Lullini
SGSandro Giannini
Sandro Giannini
LBLisa Berti
Lisa Berti
MOMaurizio Ortolani
Maurizio Ortolani
PCPaolo Caravaggi
Paolo Caravaggi
Several rehabilitation systems based on inertial measurement units (IMU) are entering the market for the control of exercises and to measure performance progression, particularly for recovery after lower limb orthopaedic treatments. IMU are easy to wear also by the patient alone, but the extent to which IMU’s malpositioning in routine use can affect the accuracy of the measurements is not known. A new such system (Riablo™, CoRehab, Trento, Italy), using audio-visual biofeedback based on videogames, was assessed against state-of-the-art gait analysis as the gold standard. The sensitivity of the system to errors in the IMU’s position and orientation was measured in 5 healthy subjects performing two hip joint motion exercises. Root mean square deviation was used to assess differences in the system’s kinematic output between the erroneous and correct IMU position and orientation. In order to estimate the system’s accuracy, thorax and knee joint motion of 17 healthy subjects were tracked during the execution of standard rehabilitation tasks and compared with the corresponding measurements obtained with an established gait protocol using stereophotogrammetry. A maximum mean error of 3.1 ± 1.8 deg and 1.9 ± 0.8 deg from the angle trajectory with correct IMU position was recorded respectively in the medio-lateral malposition and frontal-plane misalignment tests. Across the standard rehabilitation tasks, the mean distance between the IMU and gait analysis systems was on average smaller than 5°. These findings showed that the tested IMU based system has the necessary accuracy to be safely utilized in rehabilitation programs after orthopaedic treatments of the lower limb.

9 August 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MOMaurizio Ortolani
Maurizio Ortolani
ALAlberto Leardini
Alberto Leardini
CPChiara Pavani
Chiara Pavani
SSSilvia Scicolone
Silvia Scicolone
MGMauro Girolami
Mauro Girolami
CBClaudio Belvedere
Claudio Belvedere
Acquired adult flatfoot is a frequent deformity which implies multiple, complex and combined 3D modifications of the foot skeletal structure. The difficult thorough evaluation of the degree of severity pre-op and the corresponding assessment post-op can now be overcome by cone-beam (CBCT) technology, which can provide access to the 3D skeletal structure in weight-bearing. This study aims to report flatfoot deformities originally in 3D and in weight-bearing, with measurements taken using two different bone segmentation techniques. 21 such patients, with indication for surgical corrections, underwent CBCT (Carestream, US) while standing on one leg. From these scans, 3D models of each bone of the foot were reconstructed by using two different state-of-the-art segmentation tools: a semi-automatic (Mimics Innovation Suite, Materialise, Belgium), and an automatic (Bonelogic Ortho Foot and Ankle, Disior, Finland). From both reconstructed models, Principal Component Analysis was used to define anatomical reference frames, and original foot and ankle angles and other parameters were calculated mostly based on the longitudinal axis of the bones, in anatomical plane projections and in 3D. Both bone model reconstructions revealed a considerable valgus of the calcareous, plantarflexion and internal rotation of the talus, and typical Meary’s angles in the lateral and transverse plane projections. The mean difference from these angles between semi-automatic and automatic segmentations was larger than 3.5 degrees for only 3 of the 32 measurements, and a large number of these differences were not statistically significant. CBCT and the present techniques for bone shape reconstruction finally provide a novel and valuable 3D assessment of complex foot deformities in weight-bearing, eliminating previous limitations associated to unloaded feet and bidimensional measures. Corresponding measurements on the bone models from the two segmentation tools compared well. Other more representative measurements can be defined in the future using CBCT and these techniques.

19 November 2019 in Seminars in Musculoskeletal Radiology
Verified
Journal Article
Closed access
PDF file
Alberto LeardiniAlberto Leardini
Alberto Leardini
SDStefano Durante
Stefano Durante
CBClaudio Belvedere
Claudio Belvedere
PCPaolo Caravaggi
Paolo Caravaggi
CCClaudio Carrara
Claudio Carrara
ABAlberto Bazzocchi
Alberto Bazzocchi
Musculoskeletal radiology has been mostly limited by the option between imaging under load but in two dimensions (i.e., radiographs) and three-dimensional (3D) scans but in unloaded conditions (i.e., computed tomography [CT] and magnetic resonance imaging in a supine position). Cone-beam technology is now also a way to image the extremities with 3D and weight-bearing CT. This article discusses the initial experience over a few studies in progress at an orthopaedic center. The custom design of total ankle replacements, the patellofemoral alignment after medial ligament reconstruction, the overall architecture of the foot bones in the diabetic foot, and the radiographic assessment of the rearfoot after subtalar fusion for correction of severe flat foot have all taken advantage of the 3D and weight-bearing feature of relevant CT scans. To further support these novel assessments, techniques have been developed to obtain 3D models of the bones from the scans and to merge these with state-of-the-art gait analyses.

1 January 2019 in Journal of Foot and Ankle Research
Verified
Journal Article
Open access
PDF file
GRGiulia Rogati
Giulia Rogati
Alberto LeardiniAlberto Leardini
Alberto Leardini
MOMaurizio Ortolani
Maurizio Ortolani
PCPaolo Caravaggi
Paolo Caravaggi
Background: Advancements in additive manufacturing, along with new 3D scanning tools, are increasingly fulfilling the technological need for custom devices in personalized medicine. In podiatry and in the footwear industry, custom orthotic and footwear solutions are often required to address foot pathologies or morphological alterations which cannot be managed with standard devices. While laser scanners are the current gold‐standard for 3D digitization of the foot shape, their costs limit their applications and diffusion, therefore traditional operator‐dependent casting methods are still in use. The aim of this study was to design and validate a novel 3D foot scanner based on the Microsoft Kinect sensor, allowing a 3D scan of the plantar shape of the foot to be acquired in weight‐bearing.Methods: The accuracy and repeatability of the prototypal foot scanner were investigated in a population of 14 asymptomatic healthy subjects, with no history of foot or lower limb injuries. The accuracy was estimated by comparing the Kinect foot scans with those obtained with a high‐resolution laser scanner used as reference. The repeatability was assessed by comparing scans of the same foot acquired in different sessions.Results: The inter‐subject average Root Mean Square Error (RMSE) of the Kinect scans was lower than 3 mm for the whole plantar surface, and lower than 1.6 mm for the arch region alone, both in left and right feet. The repeatability, quantified as the average RMSE of pairwise comparisons between sessions, was 1.2 ± 0.4 mm.Conclusions: The present Kinect‐based 3D foot scanner showed optimal intra‐operator repeatability and its accuracy appears adequate to obtain 3D scans of the foot plantar surface suitable for different clinical applications. This device could represent a valid low‐cost alternative to expensive laser‐based scanners and could be used for automatic foot measurements, supporting the design of custom insoles and footwear.

1 May 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
PCPaolo Caravaggi
Paolo Caravaggi
AMAlessandra B. Matias
Alessandra B. Matias
UTUlisses T. Taddei
Ulisses T. Taddei
MOMaurizio Ortolani
Maurizio Ortolani
Alberto LeardiniAlberto Leardini
Alberto Leardini
ISIsabel C.N. Sacco
Isabel C.N. Sacco

1 January 2021 in Journal of Foot and Ankle Research
Verified
Journal Article
Open access
PDF file
GRGiulia Rogati
Giulia Rogati
ALAlberto Leardini
Alberto Leardini
MOMaurizio Ortolani
Maurizio Ortolani
PCPaolo Caravaggi
Paolo Caravaggi
Background: Foot healthcare research is focusing increasingly on personalized orthotic and prosthetic devices to address patient‐specific morphology and ailments. Customization requires advanced 3D image processing tools to assess foot and leg geometrical parameters and alterations. The aim of this study is to present a new software for the measurement of the foot shape from 3D scans of the foot plantar surface.Methods: A Kinect‐based scanning device was used to acquire the 3D foot shape of 44 healthy subjects. A software was developed in Matlab to measure the foot main morphological parameters from foot scans. Principal Component Analysis was used to orientate the foot scans with respect to the same reference system. Accuracy, via percentage errors and Bland‐Altman plots, and correlation of the software‐based foot parameters were assessed against manual measurements. A normalized Arch Volume Index (nAVI) was proposed and correlated to the traditional Arch Index. Test‐retest Intraclass Correlation Coefficient was used to assess the inter‐session repeatability of foot measurements.Results: The average percentage error between software and manual measurements was 1.2 ± 0.8% for foot length, 9.1 ± 3.7% for foot width, 22.3 ± 13.5% for arch height and 23.1 ± 12.7% for arch depth. Very strong correlations were observed for foot length (R = 0.97) and foot width (R = 0.83), and strong correlations for arch height (R = 0.62) and arch depth (R = 0.74). nAVI was negatively correlated to the Arch Index (R = ‐0.54). A small difference was found between software and manual measurements of foot length (Δ = 0.92 mm), a software overestimation of foot width (Δ = 8.6 mm) and underestimation of arch height (Δ = ‐1.4%) and arch depth (Δ = ‐11%). Moderate to excellent repeatability was observed for all measurements (0.67–0.99).Conclusions: The present software appears capable to estimate the foot main morphological parameters without the need for skin markers or for identification of anatomical landmarks. Moreover, measurements are not affected by the foot orientation on the scanning device. The good accuracy and repeatability of measurements make the software a potentially useful operator‐independent tool for the assessment of foot morphological alterations and for orthotics customization. nAVI may be used for a more realistic classification of foot types when 3D foot images are available.