Patrik Mitrenga

Dr. Patrik Mitrenga

Department of Fire Engineering, University of Žilina, Žilina, Žilinský, Slovakia
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2025 in Coatings
Verified
Journal Article
Open access
PDF file
PMPatrik Mitrenga
Patrik Mitrenga
Miroslava VandlíčkováMiroslava Vandlíčková
Miroslava Vandlíčková
MKMilan Konárik
Milan Konárik
This study evaluates selected flame retardants on the basis of their influence on the change of fire-technical parameters of soft and hard woods (spruce and oak) during exposure to a flame heat source. The parameters evaluated were mass loss, mass loss rate and depth of the charred layer. The experiments were carried out on simple test equipment on which the samples were exposed to direct flame while their mass was monitored. The measured data and their statistical evaluation showed a significant dependence of the mass loss on the type of retardant used (inorganic salt-based flame retardant—IS and intumescent flame retardant—IFR) and on the type of wood species. In spite of the same reaction to fire class specified by the manufacturers for both types of retardants studied, significant differences were observed in the parameters monitored. The mass loss, mass loss rate and charred layer reached much lower values when using IFR retardant, whose efficiency was higher in the order of tens of percent compared to the use of IS retardant. The use of IFR flame retardant reduced the depth of the charred layer on oak samples by up to 84% compared to untreated samples, indicating its high effectiveness and potential to increase the fire resistance of wooden structures. These results show that IFRs are more effective in the parameters studied compared to ISs despite their equal class of reaction to fire, which may have wider implications for the construction industry and highlight the need for a thorough evaluation of flame retardants based on their performance under real-world conditions.

24 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPatrik Mitrenga
Patrik Mitrenga
Linda Makovicka OsvaldovaLinda Makovicka Osvaldova
Linda Makovicka Osvaldova
MKMilan Konárik
Milan Konárik
The paper evaluates the effect of spruce wood density on the parameters of mass loss and mass loss rate during exposure to thermal load. The intention was to determine whether the effect of density is still evident after the application of flame retardants to the test samples. Groups of samples with different densities under the same retardant treatment were compared. The differences in densities of the compared groups of samples were different for each flame retardant. Water-soluble flame retardants based on inorganic salts were used. For testing, a simple test method was used in which the samples were exposed to direct flame from a Bunsen burner. The results of the study are the findings of how wood density affects the burning process of the samples treated with flame retardants. Statistical evaluation of the experimental results shows a significant effect of wood density on the monitored parameters even when flame retardants are used. For a difference in sample densities of 244 kg·m−3, there was a density dependence of the mass loss rate, with the lower density samples having a higher mass loss rate (0.158%·s−1) over the whole experimental period compared to the higher density samples (0.077%·s−1). The ANOVA test also demonstrated the influence of density on the mass loss of the samples at the above density difference. At lower density differences (51 kg·m−3 and below), the effect of sample density on the observed parameters was no longer evident. The fire spread rate parameter was also investigated. Here, a linear correlation between the difference in sample densities and the difference in the values of the above parameter at high and low densities is observed with a reliability coefficient R2 = 0.99.

25 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPatrik Mitrenga
Patrik Mitrenga
Miroslava VandlíčkováMiroslava Vandlíčková
Miroslava Vandlíčková
MKMilan Konárik
Milan Konárik
KKKatarína Košútová
Katarína Košútová
The paper assessed the impact of the heat treatment of spruce wood, the (radial and tangential) side of the specimens exposed to fire, and the type of material (prism—higher density, floor—lower density) on the combustion process and the rate of fire spread. Five groups of specimens were used—untreated spruce wood specimens, two groups of heat-treated spruce wood specimens from the prism (higher density specimens), and two groups of heat-treated spruce wood specimens from the floor (lower density specimens). In one group, the flame was applied to the radial side, and in the other group to the tangential side of the specimens. The effect on the combustion process was assessed based on the parameters of mass loss and mass loss rate over time. The effect on the rate of fire spread across the specimens was assessed by the parameter fire spread rate. These parameters were determined using a simple test method where the specimens were exposed to a direct flame at an angle of 45°. To complement the results and to assess the processes involved, the temperatures at the specimen surfaces were also measured during the experiment. The main achieved results of the study are the findings on how the heat treatment, the density, and the side of the wood along which the fire spreads affect the burning process of the wood. The results indicated a significant effect of the density of the spruce thermowood on its combustion process. The higher density radial specimens exhibited a higher mass loss rate, and the overall average mass loss of the higher density samples was 27% of the original mass higher than that of the lower density samples. Additionally, the results suggested that the heat treatment of lower-density spruce wood (floor) does not significantly affect the mass loss and the mass loss rate. The difference in the overall average mass loss of the thermowood of floor and untreated wood samples was less than 2%, which is statistically insignificant. It was also found that for thermowood, fire will spread faster on the tangential side, where the fire spread rate is 29% higher compared with the radial side (for the floor samples). Based on the findings of other authors in a similar field, the results confirm that heat-treated spruce wood is more easily ignitable than untreated wood, which was proven by the spontaneous combustion of most of the thermowood samples during the experiment compared with the untreated wood samples.

27 June 2025 in Fire
Verified
Journal Article
Open access
PDF file
DHDorota Hodúlová
Dorota Hodúlová
PMPatrik Mitrenga
Patrik Mitrenga
SGStanislava Gašpercová
Stanislava Gašpercová
Iveta MarkovaIveta Markova
Iveta Markova
Fire safety solutions for buildings in Slovakia are addressed by legislation and Slovak technical standards, which are not legally binding, but their wording is mandatory if they are referred to in an implementing regulation. Fire safety solutions for buildings in Slovakia are therefore limited mainly by legislation and technical standards. The use of fire models in fire safety solutions for buildings is common across the world, but these tools are not used in Slovakia. Their use is not prohibited by law, but it is always necessary to prove the applicability and correctness of the outputs. The paper deals with a case study of Slovak implementation of fire models when discussing the stand-off distances from fully fire-open areas. The Slovak case study addresses the fire safety solutions for buildings under the conditions of the Slovak Republic. To utilize the fire models in practice, the threshold conditions for the use of the selected FDS fire model needed to be established. This process is called a sensitivity analysis, and it is conducted based on the utilized simulation method. Based on the sensitivity analysis of FDS, the exact values of parameters can be determined, the use of which in the implementation of fire models in practice will allow accurate outputs and values of stand-off distances from fully fire-open areas in the conditions of the Slovak Republic to be obtained.

26 August 2025 in International Journal of Innovative Research and Scientific Studies
Verified
Journal Article
Open access
DHDorota Hodúlová
Dorota Hodúlová
PMPatrik Mitrenga
Patrik Mitrenga
SGStanislava Gašpercová
Stanislava Gašpercová
Fire safety solutions for buildings in Slovakia are addressed by legislation and Slovak technical standards, which are not legally binding, but their wording is mandatory if they are referred to in an implementing regulation. Fire safety solutions for buildings in Slovakia are therefore mainly limited by legislation and technical standards. The use of fire models in fire safety solutions for buildings is common worldwide, but these tools are not used in Slovakia. Their use is not prohibited by law, but it is always necessary to prove the applicability and correctness of the outputs. The paper deals with a case study of Slovak implementation of fire models when discussing the stand-off distances from fully fire-opened areas. The research addresses fire safety solutions for buildings under the conditions of the Slovak Republic. To utilize fire models in practice, the threshold conditions for the use of the selected FDS fire model needed to be established. This process is called a validation program, conducted based on the utilized simulation method. Subsequently, a general model for determining the stand-off distances from fully fire-opened areas was established. This model was verified by comparing the values of stand-off distances obtained through simulations and values derived from the prescriptive approach, which determines the stand-off distances in Slovakia following generally binding legal regulations and standards. Subsequently, an accurate general model for the solution of stand-off distances was created, which is validated with the technical standards in the Slovak Republic.

1 March 2016 in TRANSACTIONS of the VŠB – Technical University of Ostrava, Safety Engineering Series
Verified
Journal Article
Open access
PDF file
PMPatrik Mitrenga
Patrik Mitrenga
MVMiroslava Vandlickova
Miroslava Vandlickova
MHMartina Hudáková
Martina Hudáková
MSMilada Sihelská
Milada Sihelská
The paper deals with testing of a water-miscible intumescent fire retardant. Experiments are conducted by thermal analysis (TG/DTG, DSC), cone calorimeter and non-standardized methods for monitoring weight loss when exposed to flame burning. Based on the experiment results and other information the most appropriate methods for testing fire retardants are reviewed. All methods by which experiments have been carried out are described. Our own method for testing fire retardants was created. It is also evaluated the effectiveness of a representative fire retardant of wood by all mentioned methods. The result of the experiment is to evaluate the suitability of each method for testing of fire retardants and evaluation fire retardant “Plamostop”.