Panagiotis Blanos

Mr. Panagiotis Blanos

PhD researcher

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2017 in Biosensors
Verified
Journal Article
Open access
PDF file
LYLiangwen Yan
Liangwen Yan
Sijung HuSijung Hu
Sijung Hu
AAAbdullah Alzahrani
Abdullah Alzahrani
SASamah Alharbi
Samah Alharbi
Panagiotis BlanosPanagiotis Blanos
Panagiotis Blanos
Different skin pigments among various ethnic group people have an impact on spectrometric illumination on skin surface. To effectively capture photoplethysmographic (PPG) signals, a multi-wavelength opto-electronic patch sensor (OEPS) together with a schematic architecture of electronics were developed to overcome the drawback of present PPG sensor. To perform a better in vivo physiological measurement against skin pigments, optimal illuminations in OEPS, whose wavelength is compatible with a specific skin type, were optimized to capture a reliable physiological sign of heart rate (HR). A protocol was designed to investigate an impact of five skin types in compliance with Von Luschan’s chromatic scale. Thirty-three healthy male subjects between the ages of 18 and 41 were involved in the protocol implemented by means of the OEPS system. The results show that there is no significant difference (p: 0.09, F = 3.0) in five group tests with the skin types across various activities throughout a series of consistent measurements. The outcome of the present study demonstrates that the OEPS, with its multi-wavelength illumination characteristics, could open a path in multiple applications of different ethnic groups with cost-effective health monitoring.

31 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SASamah Alharbi
Samah Alharbi
Sijung HuSijung Hu
Sijung Hu
DMDavid Mulvaney
David Mulvaney
LBLaura Barrett
Laura Barrett
LYLiangwen Yan
Liangwen Yan
SASamuel Adema
Samuel Adema
Photoplethysmography (PPG) based pulse oximetry devices normally use red and infrared illuminations to obtain oxygen saturation (SpO 2 ) readings. In addition, the presence of motion artefacts severely restricts the utility of pulse oximetry physiological measurements. In the current study, a combination of green and orange illuminations from a multi-wavelength optoelectronic patch sensor (mOEPS) was investigated in order to improve robustness to subjects’ movements in the extraction of SpO 2 measurement. The experimental protocol with 31 healthy subjects was divided into two sub-protocols, and was designed to determine SpO 2 measurement. The datasets for the first sub-protocol were collected from 15 subjects at rest, with the subjects free to move their hands. The datasets for the second sub-protocol with 16 subjects were collected during cycling and walking exercises. The results showed good agreement with SpO 2 measurements (r = 0.98) in both sub-protocols. The outcomes promise a robust and cost-effective approach of physiological monitoring with the prospect of providing health monitoring that does not restrict user physical movements.

21 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LYLiangwen Yan
Liangwen Yan
YYyue yy
yue yy
Sijung HuSijung Hu
Sijung Hu
DMDavid Mulvaney
David Mulvaney
Panagiotis BlanosPanagiotis Blanos
Panagiotis Blanos
MHMatthew Hayes
Matthew Hayes
In capturing high-quality photoplethysmographic signals, it is crucial to ensure that appropriate illumination intensities are used. The purpose of the study was to deliver controlled illumination intensities for a multi-wavelength opto-electronic patch sensor that has four separate arrays each consisting of four light-emitting diodes (LEDs), the wavelength of the light generated by each array being different. The study achieved the following: (1) a linear constant current source LED driver incorporating series negative feedback using an integrated operational amplifier circuit; (2) the fitting of a linear regression equation to provide rapid determination of the LEDs driver voltage; and (3) an algorithm for the automatic adjustment of the output voltage to ensure suitable LED illumination. The data from a single centrally-located photo detector, which is capable of capturing all four channels of back-light in a time-multiplexed manner, were used to monitor heart rate and blood oxygen saturation. This paper provides circuitry for driving the LEDs and describes an adaptive algorithm implemented on a microcontroller unit that monitors the quality of the photo detector signals received in order to control each of the individual currents being supplied to the LED arrays. The study demonstrated that the operation of the new circuitry in its ability to adapt LED illumination to the strength of the signal received and the performance of the adaptive system was compared with that of a non-adaptive approach.