Purpose: To determine patient preoperative anatomical features and the parameters of implantable collamer lenses (ICLs) relevant in explaining vault variability. Setting: Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain. Design: Retrospective case series. Methods: This study comprised 360 eyes of 360 patients implanted with myopic or toric ICLs. Pentacam imaging was used for assessing white-to-white (WTW) diameter, central keratometry, and central corneal thickness. Anterior-segment optical coherence tomography was used to measure the horizontal anterior chamber angle distance (ATA), internal anterior chamber (ACQ), crystalline lens rise (CLR), anterior chamber angle (ACA), and vault. The sample was divided according to the implanted lens size (12.6 mm, 13.2 mm, and 13.7 mm). Vault predictors were identified from the variables above using multivariate regression analysis. Results: The groups showed significant statistical differences for WTW, ATA, ACQ, ACA, and vault (P < .007 for all). In general, bigger lenses were implanted in eyes with larger transverse sizes (WTW and ATA) and deeper ACQ. Also, larger ICL diameters were associated with higher vaults. Multivariate regression analysis identified the lens size (13.2 mm as reference; 12.6 mm: β [standardized coefficients] = −0.33; 13.7 mm: β = 0.42), ATA (β = −0.42), and CLR (β = −0.25), ICL spherical equivalent (β = −0.22) and patient age (β = −0.12) as predictors of the vault size (adjusted-R2 = 0.34 P < .001). Conclusions: The multivariate model explained 34% of vault variability. The predictors indicated the presence of different mechanisms regulating the vault. These involved the difference between the transverse size of the eye and the ICL, the crystalline lens protrusion, and the ICL properties, such as power and size.
Background: To identify biometric and implantable collamer lens (ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL. Methods: This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL. Preoperatively, white-to-white (WTW), central keratometry (Kc) and central corneal thickness (CCT) were measured using the Pentacam. Anterior-segment optical coherence tomography (AS-OCT, Visante) was applied preoperatively for measuring the horizontal anterior-chamber angle-to-angle distance (ATA), internal anterior chamber depth (ACD), crystalline lens rise (CLR), anterior-chamber angle (ACA) and postoperatively the vault. Eyes were divided into three vault groups: low (LVG: ≤ 250 μm), optimal (OVG: > 250 and < 1000 μm) and high (HVG: ≥ 1000 μm). Multinomial logistic regression (MLR) was used to find the sub-optimal vault predictors. Results: MLR showed that CLR, ICL size minus the ATA (ICL size-ATA), age, ICL spherical equivalent (ICLSE) and ICL size as contributing factors for sub-optimal vaults (pseudo-R2 = 0.40). Increased CLR (OR: 1.01, CI: 1.00–1.01) and less myopic ICLSE (OR: 1.22, CI: 1.07–1.40) were risk factors for low vaults. Larger ICL size-ATA (OR: 41.29, CI: 10.57–161.22) and the 13.7 mm ICL (OR: 7.08, CI: 3.16–15.89) were risk factors for high vaults, whereas less myopic ICLSE (OR: 0.85, CI: 0.76–0.95) and older age (OR: 0.92, CI: 0.88–0.98) were protective factors. Conclusion: High CLR and low ICLSE were the major risk factors in eyes presenting low vaults. In the opposite direction, ICL size-ATA was the major contributor for high vaults. This relationship was more critical in higher myopic ICLSE, younger eyes and when 13.7 mm ICL were used. The findings show that factors influencing the vault have differentiated weight of influence depending on the type of vault (low, optimal or high).
12 December 2022 in Clinical and Experimental Optometry
Biometric measurements in the context of myopia are fundamental to detect eyes at risk of developing myopia and during the follow-up of patients with myopia control treatment. Thus, the accuracy of biometers has high clinical relevance. The Myopia Master is a new biometer based on partial coherence interferometry especially dedicated to the follow-up of myopic patients. This study aims to assess the repeatability of the Myopia Master and evaluate its agreement with a swept-source optical coherence interferometry biometer (IOL Master 700). This cross-sectional prospective study assessed the biometric parameters of two groups of myopes (age range: 8-16 years old), spectacle corrected (n = 60) and orthokeratology contact lens wearers (n = 60). One senior optometrist performed two consecutive measurements per instrument, which included axial length, mean keratometry and horizontal visible iris diameter (HVID). The repeatability of each device and the agreement between devices were assessed by the dispersion of the measurement differences, for AL, mean keratometry, corneal astigmatism and HVID. The two biometers measured approximately the same value in both measurements. Test-retest repeatability tended to be lower than clinical significant thresholds, in particular, for AL and mean keratometry. Corneal-related parameters tended to have lower repeatability in the orthokeratology group, especially mean keratometry. The agreement between instruments revealed statistically significant differences between devices with the SS-OCT measuring longer eyes, steeper corneas and larger HVID. In a paediatric population, the Myopia Master showed clinically acceptable repeatability levels, but the IOL Master 700 demonstrated superior repeatability. Eyes treated with orthokeratology may compromise the repeatability of the corneal-related parameters. The Myopia Master and the IOL Master 700 are repeatable devices appropriate for monitoring myopia progression, but the differences observed do not allow their use interchangeably.
3 February 2016 in Clinical and Experimental Optometry
Purpose Increased depth‐of‐focus after cataract surgery is dependent on various ocular characteristics, including refractive astigmatism. This work studied the influence of meridional blur produced by astigmatism, and spherical blur, on distance and near visual performance in pseudophakic eyes. Methods Visual performance was assessed monocularly in 59 pseudophakes (mean ± standard deviation, 66.9 ± 7.53 years) at distance (3.0 m) and near (0.33 m) using high‐ (HC: 94%) and low‐contrast (LC: 10%) visual acuity (VA) charts. Reading performance (maximum reading speed [MRS], threshold print size [TPS] and reading acuity [RA]) was evaluated at near using a reading chart. Four refractive conditions at distance and near were monocularly simulated using the following trial lenses: distance (in‐focus: ± 0.00 DS, with‐the‐rule [WTR] astigmatism: +2.00 × 180; against‐the‐rule [ATR] astigmatism: +2.00 × 90; spherical defocus: +1.00 DS) and near (in‐focus: +3.00 DS, WTR astigmatism: +2.00 × 180; ATR astigmatism: +2.00 × 90, spherical blur: ±0.00 DS). Results Distance high‐ and low‐contrast VA were degraded by spherical and astigmatic blur in comparison to the distance in‐focus condition (p < 0.001 for all), with astigmatism in either of the forms being more harmful than spherical blur (p < 0.001 for all). At near, best HC‐ and LCVA were attained with full near correction (p < 0.001 for all) followed by the ATR and WTR astigmatism. For all conditions, the VA measured was independent of whether the astigmatism was WTR or ATR. However, MRS was higher with +3.00 DS and ATR astigmatism compared to the other conditions. RA and TPS significantly strengthened the weak pattern seen with HCVA at near, with ATR astigmatism allowing significantly better RA and TPS than WTR astigmatism (p < 0.001 for all). Conclusions Simple myopic astigmatism improved near visual performance in pseudophakic eyes at the expense of some deterioration in distance performance. ATR astigmatism degraded VA at distance marginally more than WTR astigmatism and provided a marginally better VA at near. However, the benefit at near was more explicit when measured by reading performance, confirming the role of blur orientation on visual performance.
Purpose: The distance between an implantable collamer lens (ICL) and the crystalline lens, namely vault, is a space regulated by the interaction of the ICL and the anatomical structures of the eye. This study analysed the differences in vault size between fellow eyes with similar anterior segment biometry. Patients and Methods: A retrospective case series analysed 109 cases of patients bilaterally implanted with EVO-V4c. Patients were analysed pre- and postoperatively using anterior segment optical coherence tomography. The range of vault inter-eye differences was defined as the 95% confidence interval of the differences. Bivariate correlation was applied to seek for associations between vault inter-eye differences with biometric and lens parameters (angle-to-angle, anterior chamber depth, crystalline lens rise, central corneal thickness, central keratometry, ICL spherical equivalent, horizontal compression, postoperative pupil diameter and vault). Results: Mean vault inter-eye differences were similar between fellow eyes (26.0 ± 122.5 μm). The 95% confidence interval range of the differences was ± 240.1 μm, nearly 50% of the cases presented vault inter-eye differences higher than 100 μm. The vault of the first operated eye explained 81% of the variance in the second eye vault. Vault inter-eye differences were positively correlated with the level of horizontal compression and with vault magnitude. Conclusion: Vaults measured in fellow eyes may present considerable differences, which can reach 25% of the common vault range. This reflects some degree of baseline variability in the vault. Clinically, these differences assume special relevance in cases where low or high vaults are expected.
Background: Assessing refractive errors under cycloplegia is recommended for paediatric patients; however, this may not always be feasible. In these situations, refraction has to rely on measurements made under active accommodation which may increase measurements variability and error. Therefore, evaluating the accuracy and precision of non-cycloplegic refraction and biometric measurements is clinically relevant. The Myopia Master, a novel instrument combining autorefraction and biometry, is designed for monitoring refractive error and ocular biometry in myopia management. This study assessed its repeatability and agreement for autorefraction and biometric measurements pre- and post-cycloplegia. Methods: A prospective cross-sectional study evaluated a cohort of 96 paediatric patients that underwent ophthalmologic examination. An optometrist performed two repeated measurements of autorefraction and biometry pre- and post-cycloplegia. Test-retest repeatability (TRT) was assessed as differences between consecutive measurements and agreement as differences between post- and pre-cycloplegia measurements, for spherical equivalent (SE), refractive and keratometric J0/J45 astigmatic components, mean keratometry (Km) and axial length (AL). Results: Cycloplegia significantly improved the SE repeatability (TRT, pre-cyclo: 0.65 D, post-cyclo: 0.31 D). SE measurements were more repeatable in myopes and emmetropes compared to hyperopes. Keratometry (Km) repeatability did not change with cycloplegia (TRT, pre-cyclo: 0.25 D, post-cyclo:0.27 D) and AL repeatability improved marginally (TRT, pre-cyclo: 0.14 mm, post-cyclo: 0.09 mm). Regarding pre- and post-cycloplegia agreement, SE became more positive by + 0.79 D, varying with refractive error. Myopic eyes showed a mean difference of + 0.31 D, while hyperopes differed by + 1.57 D. Mean keratometry, refractive and keratometric J0/J45 and AL showed no clinically significant differences. Conclusions: Refractive error measurements, using the Myopia Master were 2.5x less precise pre-cycloplegia than post-cycloplegia. Accuracy of pre-cycloplegic refractive error measurements was often larger than the clinically significant threshold (0.25 D) and was refractive error dependent. The higher precision compared to autorefraction measurements, pre- and post-cycloplegia agreement and refractive error independence of AL measurements emphasize the superiority of AL in refractive error monitoring.