9 July 2003 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
Piero MalcovatiPiero Malcovati
Piero Malcovati
SBS. Brigati
S. Brigati
FFF. Francesconi
F. Francesconi
FMF. Maloberti
F. Maloberti
PCP. Cusinato
P. Cusinato
ABAndrea Baschirotto
Andrea Baschirotto
This paper presents a complete set of blocks implemented in the popular MATLAB SIMULINK environment, which allows designers to perform time-domain behavioral simulations of switched-capacitor (SC) sigma-delta (/spl Sigma//spl Delta/) modulators. The proposed set of blocks takes into account most of the SC /spl Sigma//spl Delta/ modulator nonidealities, such as sampling jitter, kT/C noise, and operational amplifier parameters (white noise, finite DC gain, finite bandwidth, slew rate and saturation voltages). For each block, a description of the considered effect as well as all of the implementative details are provided. The proposed simulation environment is validated by comparing the simulated behavior with the experimental results obtained from two actual circuits, namely a second-order low-pass and a sixth-order bandpass SC /spl Sigma//spl Delta/ modulator.

1 July 2001 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
Piero MalcovatiPiero Malcovati
Piero Malcovati
FMF. Maloberti
F. Maloberti
CFC. Fiocchi
C. Fiocchi
MPM. Pruzzi
M. Pruzzi
We present a bandgap circuit capable of generating a reference voltage of 0.53 V. The circuit, implemented In a submicron BiCMOS technology, operates with a supply voltage of 1 V, consuming 92 /spl mu/W at room temperature. In the bandgap circuit proposed, we use a nonconventional operational amplifier which achieves virtually zero systematic offset, operating directly from the 1-V power supply. The bandgap architecture used allows a straightforward implementation of the curvature compensation method. The proposed circuit achieves 7.5 ppm/K of temperature coefficient and 212 ppm/V of supply voltage dependence, without requiring additional operational amplifiers or complex circuits for the curvature compensation.

2 August 2011 in Experimental Astronomy
Verified
Journal Article
Open access
PDF file
MFM. Feroci
M. Feroci
LSL. Stella
L. Stella
MKM. Van Der Klis
M. Van Der Klis
TCT. J.-L. Courvoisier
T. J.-L. Courvoisier
MHMargarita Hernanz
Margarita Hernanz
JZJ. Ziolkowski
J. Ziolkowski
High-time-resolution X-ray observations of compact objects provide direct access to strong-field gravity, to the equation of state of ultradense matter and to black hole masses and spins. A 10 m2-class instrument in combination with good spectral resolution is required to exploit the relevant diagnostics and answer two of the fundamental questions of the European Space Agency (ESA) Cosmic Vision Theme “Matter under extreme conditions”, namely: does matter orbiting close to the event horizon follow the predictions of general relativity? What is the equation of state of matter in neutron stars? The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionise the study of collapsed objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. Thanks to an innovative design and the development of large-area monolithic silicon drift detectors, the Large Area Detector (LAD) on board LOFT will achieve an effective area of ~12 m2 (more than an order of magnitude larger than any spaceborne predecessor) in the 2–30 keV range (up to 50 keV in expanded mode), yet still fits a conventional platform and small/medium-class launcher. With this large area and a spectral resolution of <260 eV, LOFT will yield unprecedented information on strongly curved spacetimes and matter under extreme conditions of pressure and magnetic field strength.

25 June 2007 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MGMarco Grassi
Marco Grassi
Piero MalcovatiPiero Malcovati
Piero Malcovati
ABAndrea Baschirotto
Andrea Baschirotto
In this paper, we present the design and the characterization of a wide-dynamic-range interface circuit for resistive gas-sensors able to operate without calibration. The circuit is based on resistance-to-frequency conversion, which guarantees low complexity. The state-of-the-art of this measurement method has been improved first by separating the resistance value controlled oscillator circuit (RCO) from the sensing device, thus leading to higher linearity performance, and then by exploiting a novel digital frequency measurement system. Measurement results on a silicon prototype, designed in a 0.35-mum CMOS technology, show that the circuit achieves, without calibration, a precision in resistance measurement of 0.4% over a range of 4 decades and better than 0.8% over 5 decades (dynamic range, DR = 141 dB). Furthermore, after calibration, it reaches a precision of 0.4% for resistance values ranging between 1 kOmega and 1 GOmega, thus leading to a DR of 168 dB. The prototype chip consumes less than 15 mW from a 3.3-V supply.

20 January 2003
Verified
Conference Paper
Closed access
SBS. Brigati
S. Brigati
FFF. Francesconi
F. Francesconi
Piero MalcovatiPiero Malcovati
Piero Malcovati
DTD. Tonietto
D. Tonietto
ABA. Baschirotto
A. Baschirotto
FMF. Maloberti
F. Maloberti

30 January 2024 in IEEE Access
Verified
Journal Article
Open access
EMElisabetta Moisello
Elisabetta Moisello
LNLara Novaresi
Lara Novaresi
ESEshani Sarkar
Eshani Sarkar
Piero MalcovatiPiero Malcovati
Piero Malcovati
TCTiago L. Costa
Tiago L. Costa
EBEdoardo Bonizzoni
Edoardo Bonizzoni
Piezoelectric Micromachined Ultrasonic Transducers (PMUT) and Capacitive Micromachined Ultrasonic Transducers (CMUT) have seen great developments in recent years, both in terms of performance and scope of applications within the biomedical ultrasound domain. This paper presents a review of the state-of-the-art of PMUT and CMUT technologies, focusing on their principle of operation, microfabrication techniques and use in different biomedical imaging and therapeutic applications. The advantages and drawbacks of PMUT and CMUT technologies in comparison with conventional bulk transducers are highlighted, the trade-offs among PMUTs and CMUTs are discussed, and their relevance in the current landscape of medical diagnostics and therapeutic uses is outlined, thus providing a clear overview of these promising technologies for the present and the next generation biomedical ultrasound applications.